Home /Used Measuring & Analysing Instruments /

EN 136 Thermal Radiation Test Equipment for Full Face Masks with Artificial Lung

EN 136 Thermal Radiation Test Equipment for Full Face Masks with Artificial Lung

Brand Name:AI
Certification:ISO9001
Model Number:RRT
Minimum Order Quantity:1 set Thermal Radiation Test Equipment
Delivery Time:60 days
Payment Terms:Western Union, T/T, L/C
Contact Now

Add to Cart

Verified Supplier
Location: Changsha Hunan China
Address: Hi-tech Developing Industrial Area, Liuyang City,Changsha,Hunan Province,China
Supplier`s last login times: within 30 hours
Shipping
lt's easy to get a shipping quote! Just click the button below and complete the short form.
Get Shipping Quote
Product Details Company Profile
Product Details

Product introduction
The Full Face Mask Thermal Radiation Test Equipment is suitable for testing the radiation resistance of full face mask respiratory protective devices in EN136 standard. Its purpose is to detect whether the mask will cause protection failure after being exposed to the standard heat radiation source after the standard test time.

Full face masks for diving apparatuses are not included in the scope of this standard.


Performance characteristics
1. The Full Face Mask Thermal Radiation Test Equipment is equipped with electric heating tube heating device, the main heater power is 4000W, the auxiliary heater power is 2000 W, which is regulated by two PID temperature controllers.
2. Stainless steel reflector used to enhance the thermal radiation performance applied on the mask;
3. The Full Face Mask Thermal Radiation Test Equipment has metal head mould device, which can wear face mask and breathe freely;
4. The sliding track of the metal head mould can move its horizontal position and adjust the distance from the mask to the radiator.
5. The Full Face Mask Thermal Radiation Test Equipment is provided with a water-cooled heat flow meter for measuring the heat radiation flux at the standard distance;
6. The test equipment adopts artificial lung breathing device, breathing is a sinusoidal output mode, which truly simulates human breathing.
7. PLC control mode, breathing frequency and breathing volume can be set freely.
8. Micro-differential pressure sensor device, which can automatically detect the failure of the mask in the process of testing.


Installation requirements

1Power supply220V,30A
2Dimension1,240(W)X700mm(D)X1,600(H)mm
3Weight152KG
4Test objectFull face mask
5Test standardEN 136,GB/T 16556