​ISO 5658-2 Lateral Flame Spread Testing Equipment For Walls Surfaces by ASTM E 1317

Brand Name:AI
Certification:ISO
Model Number:SFT
Minimum Order Quantity:1 SET Lateral Flame Spread Testing Equipment
Delivery Time:60 days
Payment Terms:Western Union, T/T, L/C
Contact Now

Add to Cart

Verified Supplier
Location: Changsha Hunan China
Address: Hi-tech Developing Industrial Area, Liuyang City,Changsha,Hunan Province,China
Supplier`s last login times: within 30 hours
Product Details Company Profile
Product Details

Lateral Flame Spread Testing For Walls Surfaces

Introduction

Lateral Flame Spread Testing Equipment is used to evaluate combustion characteristics of rail materials and ship materials and measures spread rate of flame, flame for ignition by distances, CFE (Critical Flux at Extinguishment) and total heat release. This test method is originated from ISO 5658-2 (Reaction to fire tests Spread of flame- Part 2 Lateral spread on building products in vertical configuration) and measures combustion characteristics of vertical specimen (155mmX800mm).

  • ​ISO 5658-2 : Reaction to fire tests Spread of flame - Part 2 Lateral spread on building products in vertical configuration

  • IMO Resolution A. 653(16): Recommendation on fire test procedures for flammability of bulkhead, ceiling and deck finish materials

  • ​ ASTM E 1317 : Standard test method for flammability of marine surface finishes


Feature

  • The Lateral Flame Spread Testing Equipment consists of a radiant panel having dimensions of 280 x 483 mm, mounted vertically, and making an angle of 15° with the specimen.

  • ​ The orientation of the panel results in an incident radiant flux that decreases from 50 kW/m² at one end to approximately 1 kW/m² at the other end of the specimen.

  • ​ The sample is ignited by a non-impinging, gas/air pilot flame.

  • ​ Viewing rakes placed at a 50-mm spacing along the specimen.

  • ​ Heat Flux Meter - for setting the irradiance level at the surface of the specimens, the range from 0-50KW/m2.

  • ​ Portable water cooling system without need for waterworks and plumbing when using the Heat Flux meter.

  • ​ The radiant burner system is fully automatic, with spark ignition and safety interlocks.

  • ​ MFC (Mass Flow Controller) to easily measure the heat amount of methane gas in measuring critical heat flux.

  • ​ Camcorder to observe and save test conditions in a program during tests.

  • To meet the IMO specification a stack is fitted complete with thermopile for estimating heat release rate.

  • ​ Records the spread rate of flame after this records ignition and extinguishment time of flame for each distance of specimens. And the other test results is Heat for ignition (MJ/㎡), Heat for sustained burning (MJ/㎡), Critical flux at extinguishment (kW/㎡), Average heat for sustained burning (MJ/㎡), Total heat release (kW),Peak heat release rate (kW) .

Installation requirements

Electrical110V AC 60Hz / 230V AC 50Hz, 10A
Ambient Temperature10°C to 35°C
Gas suppliesPropane Gas, Methane Gas, Compressed Air
Optional gasAcetylene Gas
Dimensions

1650 mm (W) x 810 mm (H) x 1985 mm

Weight228KG
Applicable standardsISO 5658-2 IMO Spread of Flame Apparatus

China ​ISO 5658-2 Lateral Flame Spread Testing Equipment For Walls Surfaces by ASTM E 1317 supplier

​ISO 5658-2 Lateral Flame Spread Testing Equipment For Walls Surfaces by ASTM E 1317

Inquiry Cart 0