NFPA 702 45 ° Flammability Test Equipment Of Wearing Apparel CA TB 117

Brand Name:AI
Certification:ISO
Model Number:AIC-1230
Minimum Order Quantity:1 SET NFPA 702 45 ° Flammability Test Equipment
Delivery Time:30 days
Payment Terms:Western Union, T/T, L/C
Contact Now

Add to Cart

Verified Supplier
Location: Changsha Hunan China
Address: Hi-tech Developing Industrial Area, Liuyang City,Changsha,Hunan Province,China
Supplier`s last login times: within 30 hours
Product Details Company Profile
Product Details

45 ° Flammability of Wearing Apparel Apparatus

Introduction
This 45 ° Flammability Apparatus is designed according to the latest edition of the national standard GB/T14645 design and manufacturing.It applies to textile fabric in under 45 ° combustion, determination of the damaged area and damage length determination of heat or melt number to provide exposure to the flame length.

Combustion evaluation of refractory materials fire-resistant and can be based on compliance with the implementation of standards, measurement of sampleis installed at a45 degreeangle light and perfect combustion combustion characteristics.

45 degree flammability apparatus is used for measuring burning time and passive smoke glow time, graphic placement sample received someradiation,and fixed heat generated in the Chamber.


Standards
• ASTM D 1230:
• NFPA 702:
• CA TB 117 (2000):


Main Features:
Structure parts:
1, Test box is painted treatment, beautiful, corrosion-resistant;
2, Heat-resistant glass window easy to observe internal test status;
3, Internal tooling materials are made of stainless steel;
4, Power switch and start switch;
5, Tank top and side of the box have six air vents;
6, Do different experiments to replacesampleholder;
7, The sample holder should be replaced when doing different experimental;
8, Japan importedflowcontrol valve, precise control of the flame height;
9, Imported brands gauge and pressure regulator valve;

Damaged area of the test section:
• Needle valve adjust flame height to 45 ± 2m;
• Complete combustion time: The counter display glow time, resolution 0.1s;
• Glow time:Thecounter display complete combustion time, resolution 0.1s;
• Flame spread time: The set time of sample ignition (flame spread time);
• The counter is set to "0" reset switch;
• Temperature display range and accuracy: 0 ~ 90 ± 1 ºC;
• Imported brands gauge and pressure regulator, gas pressure can be displayed;
• Complete combustion stop switches;
• Planimeter is optional.

Specification

1Power supplyAC 220V,50/60Hz,5A
2Size750*300*900 mm³
3Weight30KG
4Flame height scaleOne
5Sample holderOne
6AuxiliariesVacuum cleanners,propane

China NFPA 702 45 ° Flammability Test Equipment Of Wearing Apparel CA TB 117 supplier

NFPA 702 45 ° Flammability Test Equipment Of Wearing Apparel CA TB 117

Inquiry Cart 0