Multiple Interface Energy Efficiency Management Power Distribution Monitor DDS3102-3N

Brand Name:Willfar Information Techonology Co., Ltd.
Certification:CPA/CMC/CE
Model Number:DDS3102-3N
Minimum Order Quantity:100
Delivery Time:30 days
Payment Terms:T/T
Contact Now

Add to Cart

Active Member
Location: Changsha Hunan China
Address: Wasion Industrial Park, 468 West Tongzipo Road, Yuelu District, Changsha, Hunan Province, PRC
Supplier`s last login times: within 2 hours
Product Details Company Profile
Product Details

Energy Efficiency Management Device Single-phase Power Distribution Monitor DDS3102-3N


Company Profile
Willfar Information Technology Co., Ltd.
- Established in 2004;
- Listed on the STAR Market of the Shanghai Stock Exchange in December 2019;
- Leading supplier of meter reading (AMI) equipment and operation service;
- The first company to develop "One DCU Reading Multi-meter" solution in China;
- The first company to have large-scale application of technologies and systems like "CPU smart-card Charge and Control", "One DCU Reading Multi-meter", LoRa-based RF Communication and "District Metering Area (DMA)”

Introduction


- DDS3102-3N single-phase power distribution monitor is a device with the function of measurement recording, power consumption recording, remote signaling and remote control, LCD display and network communication.


- The monitor can measure voltage, current, power, power factor, frequency and other power network parameters;


- It can record active and reactive power; RS-485 communication interface supports MODBUS-RTU and DL/T 645-2007 dual communication protocols;


- With switch input function, can be configured with switch output and transmission output functions.


Technical Parameters


Item

Technical Parameters

VoltageReference Voltage Un: AC 380V, AC220V, AC100V
Measuring Range: 10V~460V
Power Consumption: < 0.05VA
Accuracy: RMS 0.2 %
Resolution: 0.01V
CurrentNominal Current In:1A, 1.5A, 5A
Measuring Range: 0.001In ~ 10A
Power Consumption: < 0.05VA (single line nominal current)
Accuracy: RMS 0.2 %
Resolution: 0.001A

Power

(Active/Reactive/Apparent)

Accuracy: 0.5%
Resolution: 0.001kW/kvar/kVA
Line FrequencyMeasuring Range: 45 Hz~65 Hz
Accuracy: 0.2%
Resolution: 0.01 Hz
Active Power

Level of Accuracy: 0.5S,

Resolution: 0.01 kWh

Reactive Power

Level of Accuracy: Level 2;

Resolution: 0.01 kvarh

Power Pulse Output

Active Power Pulse Output

Opto-isolator, 4000VRMS

Switch Output

(Optional)

1-way for Electromagnetic Relay Output

Normally Open Type

Contact Rating: AC 250V /5A;DC 30V /5A

Switch Input

2-way Dry Contact Input

Opto-isolator, 4000VRMS

Transducing (analog quantity) Output

(Optional)

4-way Transducing Output

Current Output Type (4~20mA or 0~20mA or 0~24mA)

Voltage Output Type (0~5V or 0~10V)

Accuracy: 0.5%

RS-485 Communication Interface

(Optional)

接口类型:两线半双工

通信速率:1200bps~9600bps

规约:Modbus-RTU 和DL/T 645-2007

Working Temperature-25℃~+60℃
Limit Working Temperature-35℃~+70℃
Relative Humidity≤ 95% (non-condensing)
Power SupplyAC/DC
Maximum Input Range: 40V~265V
Power Consumption: ≤1W,2VA
Dimension

Case Dimension (mm): 72×72×85

Hole Diameter (mm): 67×67

WeightAround 243g

Certificate


GB/T17215.321-2008

GB/T17215.322-2008

GB/T17215.323-2008

DL/T 645-2007

Modbus-RTU


Features


DDS3102-3N adopts a high-precision sampling unit and a high-speed MCU data processing unit, which can realize high-precision, wide-range accurate measurement and rapid data analysis;

A segment-code type multi-line wide angle liquid crystal display screen enables various contents displaying; the liquid crystal screen is equipped with white backlight, which can meet the requirements of consulting data in the dark environment; using non-volatile memory to store all kinds of data, the data can be saved for a long time even encountering power loss.

It supports RS-485 communication interface and industrial standard communication protocol, and the networking mode is convenient and flexible; different possible expansion on functional modules enables the different interface demands of users.


1. Full Qualification: CPA and measurement license CMC.


2. High Precision: measure / measure the whole power parameters, the accuracy of active power is Level 0.5s, the accuracy of reactive power is Class 2.


3. Wide Voltage: AC / DC operation is derived from adaptation, 40~420V AC/DC input range.


4. Multi-communication: 1-way 485 communication interface, supporting MODBUS-RTU and DL/T645-2007 protocols.


5. Multiple Interface: 2-way for switch inputs, 1-way for relay output, 4-way for analog transducing output.


6. High Performance: dustproof and waterproof, meet the national standard double insulation, level 4 EMC anti-disturbance test, class b level RF electromagnetic field interference.


Function

Model

Function

3V

3A

3B

3H

3C

3M

3E

3N

Voltage Measuring
Current Measuring
Frequency Measuring
Active Power Measuring
Reactive Power Measuring
Power Factor Measuring
Apparent Power Measuring
Active Power Usage Measuring
Reactive Power Usage Measuring
Active Power Pulse Output
Out-of-limit Alarm Function
Transducing Output Function
Switch Input (Remote Signaling) Function
Switch Input (Remote Control) Function
RS-485 Communication Function

Note: "√" indicates the basic function of each module. "" indicates the optional functions of the model.


Situation


Widely applied in transformer and distribution automation system, industrial control and automation system, energy management system and community power monitoring and other occasions required energy efficiency monitoring.


Energy Pulse Output


The monitor provides active power pulse output and internal Opto-isolator. The pulse output width is (80 ±20) ms,. The maximum allowing current is 10mA (DC), and the working voltage range is 5V~80V (DC).


Switch Input Interface


The monitor is equipped with two digital switch input interfaces, which are connected by passive dry contact. The terminal marks are DI1, DI2 and COM, in which the COM interface is a common pole.


Relay Output Interface


The monitor is equipped with relay output interface, which can be used for alarm indication or protection control output in many cases. The electrical parameters of the internal relay are: AC 250V/DC30V, 5A.


Dimension


F
China Multiple Interface Energy Efficiency Management  Power Distribution Monitor DDS3102-3N supplier

Multiple Interface Energy Efficiency Management Power Distribution Monitor DDS3102-3N

Inquiry Cart 0