Add to Cart
Brick Industry Dust General Ventilation Fan 2000pa Usewd In Industrial Fields
This series of centrifugal fans has high efficiency, low noise and stable performance curve. Mainly used for indoor ventilation, dehumidification and dust removal, etc. in factories and mines, stadiums, opera houses, basements, large and small hotels, restaurants, shopping malls and large buildings. It can also be used as a gas recycler with other types of machinery.
Brick Industry Dust General Ventilation Fan 2000pa Usewd In Industrial Fields | |||
Centrifugal fan | Air Flow | 8000~50000 | m3/h |
Pressure | 900~3400 | Pa | |
Rotating speed | 2900/1450/960/730 | r/min | |
Material | Carbon steel | ||
Motor | Power | 4~55 | kw |
Voltage | 220/380/440/6000/6600 | v | |
Frequency | 50/60 | hz |
1. Centrifugal fans can convey air and other non-hyperbolic gas
which are not harmful to the human body and will not corrode steel
and iron materials.Centrifugal fans with Compact structure.It is
applicable for the indoor ventilation and air exchange to the
common factories and architectures.
2.The impeller will do by dynamic balancing tests. It greatly
improves the stability of the impeller operation, and reduces the
vibration and noise.The Fan with advantages of small volume, light
weight, angle adjustable and convenient for installation and
maintenance.
3. The adhesive materials are not allowed in the gas.Transportation
gas temperature at -20℃ ~ 200℃.The fan performance be test by
airway or AMCA both available, the fan performance data is truth
and reliable. Its containing dust and hard particles should not
exceed 150mg/m³, gas temperature not exceed 80°C.
Fan Type
The fan shall be of the single-inlet centrifugal type with the
backward curved steel wheel. The drive types shall be direct,
coupling or belt.
Standards and Codes
The design and manufacturing of the fan shall comply with JB/T
10563-2006 Technical Specification for General Purposes Centrifugal
Fans; The wheel dynamic balancing test shall comply with JB/T
9101-1999 Fan Rotor Balance; The wheel overspeed test shall comply
with JB/T 6445-2005 Overspeed Test for Industrial Fan Impeller; The
air performance test shall comply with JB/T AMCA 210-99 Laboratory
Methods of Testing Fans for Aerodynamic Performance Rating. The
welding technique shall comply with JB/T 10213-2000 Technical
Specification for Fan Welding Inspection; The fan safety shall
comply with GB/T 19074-2003 Industrial fans--Mechanical safety of
fans--Guarding.
Centrifugal fan production process:
Case Show: