Heavy Duty V-Belt Driven High Pressure High Wear Resistance Dust Collector Fan


Detail introduction


9-03 series fan-type iron furnace special high-pressure centrifugal fan, is suitable for IL/h, 2L/h, 3L/h, 3L/h, 7L/h melting rate of iron furnace blast performance requirements.

The fan can also be used as the blast for various furnace forging furnaces.

It is also suitable for conveying air and non-corrosive, non-self-igniting, non-viscous materials or light powder/debris/short fiber materials.

It can output high pressure and is suitable for any industrial occasion where high pressure & normal temperature gas is required.

The energy transfer efficiency is high, the energy of the motor is directly applied to the impeller, and there is no energy consumption during the transfer.


Product features


1. The motor uses high-efficiency and energy-saving motors from China's leading motor manufacturers (and can also install branded motors required by users), with reliable quality and lower energy consumption.

2. It is made of high quality carbon steel, stainless steel or other metal materials are available upon request.

3. The impeller is subjected to a high standard of dynamic balance correction to ensure stable operation of the fan.

4.After the completion of production, after running test and vibration value detection, the operation is reliable.


Technical data


seriesmodelRotation Speed
(r/min)
Total Pressure
(Pa)
Air Capacity
(m³/h)
Power
(kW)
9-034D290022852452329765945.57.5
4.5D290028933060469593891115
5D2900357038546440128801522
5.6D2900448248059048180953045
6.3D1450142215006441128827.511
7.1D1450180419429220184391118.5
8D145022852462131892637818.530
9D14502893309918779375583755
10D14503570385425760429335590
11.2D960145019614835239617238130160
12.5D7309601412263825329666202290
14D73096017753305355869359645160
16D730960231442955312013971275280

Application


1. In the factory, the workshops, warehouses and other departments are equipped with centrifugal fans, which play a role in ventilation, ensure the fresh air in the workshop, and help to purify the working environment and the health of employees. At the same time, the factory warehouse is equipped with centrifugal fans to dry the air to ensure that the mechanical equipment or other industrial products maintain the original quality.

2. Install centrifugal fans in mines and tunnels to re-enter fresh air and exhaust dirty air to ensure air circulation in the mines and tunnels.Centrifugal fans can help dust discharge, ensure air transparency in mines and tunnels, and ensure the health of workers in mines and tunnels.

3. A centrifugal fan is installed in the cooling tower, which not only plays the role of ventilation and ensures the normal operation of the cooling tower, but also plays a positive role in improving the cooling effect of the cooling tower by the large flow wind generated by the centrifugal fan.

4. Main ventilator in coal mine is an important equipment to ensure normal ventilation in underground mine, which not only affects the production capacity of coal mine, but also is very important to the safety of mining industry.

5. Centrifugal fans are widely used in boilers and industrial furnaces. They mainly play the role of ventilation and air induction. On the one hand, they ensure the environment of the boiler room or industrial kiln. On the other hand, they allow the replacement of oxygen-enriched air, which makes the firepower of the boiler or kiln more fierce and saves coal to a certain extent. Wait for power resources to reduce enterprise production costs.


FAQ


1. What parameters need to be provided when you design the Heat Dissipation Power Plant Blower Fan?

Answers: Air flow, total pressure or static pressure, inlet temperature, local voltage and frequency, Altitude etc.

If there is flammable and explosive gas, or big dust loading in the medium, please also inform the designer.


2. How about your company’s pre-sales service and after-sales service?

Answers: Before our cooperation, we have the professional technical team to help you make the technical solution according to your working condition, to make sure the centrifugal fan efficiency operation.

After sales service, we will offer 12 months’ repairing service, and provide lifelong follow-up services. Besides, our engineers are available for going abroad to offer the repairing service.


3. Does your company have qualifications?

Answers: SIMO Blower has obtained ISO 9001-2008, CE, TUV certifications and so on.