Home /Other Drive & Storage Devices /

Steam Power Plant Fan Gas Delivery Belt Driven Centrifugal Fan

Steam Power Plant Fan Gas Delivery Belt Driven Centrifugal Fan

Brand Name:SIMO
Certification:CE, ISO9001:2008,TUV
Model Number:SIMO Blower 6-03
Minimum Order Quantity:1 Set
Delivery Time:15-35 Days
Payment Terms:T/T, L/C, Payment Term Is Negotiable
Contact Now

Add to Cart

Verified Supplier
Location: Xinxiang Henan China
Address: No.343, SIMO Road, FengQuan District, XinXiang City, HeNan Province, China
Supplier`s last login times: within 31 hours
Shipping
lt's easy to get a shipping quote! Just click the button below and complete the short form.
Get Shipping Quote
Product Details Company Profile
Product Details

Steam Power Plant Gas Delivery V-Belt Driving Long Life Air Fan


Introduction


6-03 series medium pressure fans can be used to transport normal temperature or high temperature clean gas, dusty gas, flammable gas, corrosive gas, powder or granular materials, fiber materials, etc.

Mainly used in the industrial field, typical applications are: forced ventilation, forced cooling and heat dissipation, material drying, air purification equipment, industrial dust collector system, air filtration system, flue gas desulfurization, flue gas denitrification, boiler system, kiln system , air supply and induced draught system, industrial boiler primary air fan, secondary air fan, ventilation of various large-scale mill systems (cement mill, coal powder mill, industrial waste heat recovery device, ore powder sintering (sintering machine), Coke production (coking oven), pressurization or decompression sealing of industrial equipment, recovery of industrial waste gas, etc.

Steam Power Plant Gas Delivery V-Belt Driving Long Life Air Fan is the most widely used fan series in the industrial field.


Technical data


PRODUCT PARAMETERS
Power Plant Fan
Application
TemperatureNormal temperature air, Hot air
Air compositionClean air, Dusty air, Corrosive gas, Combustible gas,Powder materials, Light particle materials
Power Plant Fan
Performance
Impeller diameter400~2500mm
Speed of mainshaft

≤4000

rpm
Pressure range732~12086Pa
Flow range585~141977m3/h
Power Plant Fan
Structure
BladeBackward
Impeller supportSWSI (Single Width, Single Inlet), Impeller overhung.
DrivetrainV-BeltCan assign
LubricationOil bath lubrication
Bearing coolingAir cooling, Water cooling, Oil cooling
Power Plant Fan
System
configuration
MotorABB, SIEMENS, WEG, TECO, SIMO, Chinese brand…

Can assign

ImpellerQ235, Q345, SS304, SS316, HG785, DB685...

Casing, Air inlet cone,

Air inlet damper

Q235, Q345, SS304, SS316, HG785, DB685...
Main shaft45# steel(High-strength carbon structural steel), 42CrMo, Stainless steel...
BearingFAG, SKF, NSK, ZWZ…
Power Plant Fan
Optional
components
System base frame, Protective screening,Silencer, Inlet & Outlet pipeline compensator,
Inlet & Outlet flange, Damper, Electric actuator, Shock isolator, Diaphragm coupling, Fluid coupling, Motor rain cover, Temperature sensor, Vibrating sensor, Soft starter, Inverter, Special Electrical Motor,System monitoring Instrument, Lube system, Overhead lube tank etc.


Advantages and Features


1. It can output higher outlet pressure and provide more gas flow at the same time, low noise. Stable operation at higher media temperatures.

2. The variable inlet damper can be used to flexibly adjust the pressure and flow of the fan during operation. The variable frequency motor can also be selected to adjust the pressure and flow of the fan by changing the speed.

3. Bearing cooling method: according to gas temperature and operating environment conditions choose low-cost water-cooling method or oil-cooling method with good heat dissipation performance. For extremely high temperature operating conditions, can also be installed with an electronic cooler, absolute protection of the reliable operation of the fan system.

4. The material of impeller and main shaft, we will choose high-strength carbon steel, low-alloy steel, high-temperature alloy steel, high temperature &high-strength alloy steel for different working conditions temperature and working speed, so that the impeller and main shaft at high temperature still maintain reliable strength.


FAQ


1. What parameters need to be provided when you design the industrial centrifugal fans?

Answers: Air flow, total pressure or static pressure, inlet temperature, local voltage and frequency, Altitude etc.

If there is flammable and explosive gas, or big dust loading in the medium, please also inform the designer.

2. How about your company’s pre-sales service and after-sales service?

Answers: Before our cooperation, we have the professional technical team to help you make the technical solution according to your working condition, to make sure the centrifugal fan efficiency operation.

After sales service, we will offer 12 months’ repairing service, and provide lifelong follow-up services. Besides, our engineers are available for going abroad to offer the repairing service.

3. Does your company have qualifications?

Answers: SIMO Blower has obtained ISO 9001-2008, CE, BV certifications and so on.


China Steam Power Plant Fan Gas Delivery Belt Driven Centrifugal Fan supplier

Steam Power Plant Fan Gas Delivery Belt Driven Centrifugal Fan

Inquiry Cart 0