Home /Financial Equipment /

Large SIMO Blower Coal Fired Boiler Fans In Thermal Power Plant

Large SIMO Blower Coal Fired Boiler Fans In Thermal Power Plant

Brand Name:SIMO
Certification:CE, ISO9001:2008,TUV
Model Number:SIMO Blower 5-11
Minimum Order Quantity:1 Set
Delivery Time:15-35 Days
Payment Terms:T/T, L/C, Payment Term Is Negotiable
Contact Now

Add to Cart

Verified Supplier
Location: Xinxiang Henan China
Address: No.343, SIMO Road, FengQuan District, XinXiang City, HeNan Province, China
Supplier`s last login times: within 31 hours
Shipping
lt's easy to get a shipping quote! Just click the button below and complete the short form.
Get Shipping Quote
Product Details Company Profile
Product Details

Large Capacity Coal-Fired Boiler Thermal Power Plant Air Blower Fan


Introduction


Large Capacity Coal-Fired Boiler Thermal Power Plant Air Blower Fan is boiler induced draft fan with a total internal pressure efficiency of 90.5% specially designed to be suitable for various coal quality and equipped with a smoke-and-dust removal device (1~20 tons/hour).

This type of fan is currently used in the boiler industry. The air volume of the induced draft fan and the difference in wind pressure are relatively large, in order to adapt to the above situation, considering the practicability of the fan, in addition to the 20-ton boiler ID fan need large power coupling direct transmission, the other uses the triangular belt type transmission.

This can use different speeds to meet the requirements of various dust collectors in the same tonnage boiler, combined redundant fan series and machine number.


Technical data


PRODUCT PARAMETERS
Blower Fan
Application
TemperatureNormal temperature air, Hot air
Air compositionClean air, Dusty air, Corrosive gas, Combustible gas,Powder materials, Light particle materials
Blower Fan
Performance
Impeller diameter

400-900

mm
Speed of mainshaft

1740~2900

rpm
Pressure range

990~3197

Pa
Flow range

2750~36140

m3/h
Blower Fan
Structure
BladeBackward
Impeller supportSWSI (Single Width, Single Inlet), Impeller overhung.
DrivetrainV-BeltCan assign
LubricationOil bath lubrication
Bearing coolingAir cooling, Water cooling, Oil cooling
Blower Fan
System
configuration
MotorABB, SIEMENS, WEG, TECO, SIMO, Chinese brand…

Can assign

ImpellerQ235, Q345, SS304, SS316, HG785, DB685...

Casing, Air inlet cone,

Air inlet damper

Q235, Q345, SS304, SS316, HG785, DB685...
Main shaft45# steel(High-strength carbon structural steel), 42CrMo, Stainless steel...
BearingFAG, SKF, NSK, ZWZ…
Blower Fan
Optional
components
System base frame, Protective screening,Silencer, Inlet & Outlet pipeline compensator,
Inlet & Outlet flange, Damper, Electric actuator, Shock isolator, Diaphragm coupling, Fluid coupling, Motor rain cover, Temperature sensor, Vibrating sensor, Soft starter, Inverter, Special Electrical Motor,System monitoring Instrument, Lube system, Overhead lube tank etc.


Advantages and Features


1. It is capable of outputting a higher outlet pressure while providing more gas flow with lower noise. Stable operation at higher media temperatures.

2. The adjustment door can be used to flexibly adjust the pressure and flow of the fan during operation. It can also be equipped with a variable frequency motor to adjust the pressure and flow of the fan by changing the speed.

3. The bearing cooling method selects a low-cost water-cooling method or an oil-cooling method with better heat dissipation depending on the gas temperature and the conditions of the use environment. For extremely high temperature operating conditions, an electronic cooler can also be added to absolutely protect the reliable operation of the fan system.

4. For the materials of impeller and main shaft, for different working conditions and working speed, we will choose high-strength carbon steel, low-alloy steel, high-temperature alloy steel, high temperature resistant high-strength alloy steel, make the impeller and main shaft to maintain reliable strength at high temperatures.

5. For dust-containing gas, we can meet various working conditions from a small amount of dust to a very large dust content. After special treatment, the surface hardness of the blade can reach HRC60~70, which can extend the life of the impeller by more than 3 times.

6. The bearing housing is reserved for temperature and vibration sensor mounting positions, for convenient to install the fan operation monitoring device.

7. The weld and the main shaft of the impeller are ultrasonic flaw detection to ensure that there are no welding defects and material defects to ensure strength.

8. After the production is completed, all products are tested for running and vibration values for reliable operation.

9. There are a variety of accessories to choose from.


FAQ


1. What parameters need to be provided when you design the industrial centrifugal fans?

Answers: Air flow, total pressure or static pressure, inlet temperature, local voltage and frequency, Altitude etc.

If there is flammable and explosive gas, or big dust loading in the medium, please also inform the designer.

2. How about your company’s pre-sales service and after-sales service?

Answers: Before our cooperation, we have the professional technical team to help you make the technical solution according to your working condition, to make sure the centrifugal fan efficiency operation.

After sales service, we will offer 12 months’ repairing service, and provide lifelong follow-up services. Besides, our engineers are available for going abroad to offer the repairing service.

3. Does your company have qualifications?

Answers: SIMO Blower has obtained ISO 9001-2008, CE, BV certifications and so on.


China Large SIMO Blower Coal Fired Boiler Fans In Thermal Power Plant supplier

Large SIMO Blower Coal Fired Boiler Fans In Thermal Power Plant

Inquiry Cart 0