

Add to Cart
CCC China FM200 Gas Suppression System Cabinet Type Fire Computer
Room Library
Cabinet extinguishing equipment don't have to set up a dedicated storage bottle, the whole cabinet put oneself in another's position is set in the protection zone, suitable for computer rooms, archives, valuables such as library, communication machine room space smaller protection zone, a few cabinet device can also be used to protect a large protection zone. When building to set up a dedicated store between bottles, or although there is a store, but the transmission distance is far, can not meet the requirement of the engineering design, or protective zone inconvenient installation system pipe network.
Bad protection area clean and tidy, can discharge extinguishing agent will start automatically when you fire extinguishing equipment. Injection time is short, fast extinguishing, the device can be equipped with my company the production of single zone for gas cabinet extinguishing system control panel. Start the way for the automatic control, manual electric control and mechanical emergency manual control three. Automatic control, manual electric control switch can be performed. Manual control should be used in general, in the case of reserve no one can be converted into automatic control. When electric control cannot perform automatic control and manual, mechanical emergency manual control should be adopted.
Model | Storage Device Specification | Agent Volume | Outer Size L*W*H(mm) | Storage Pressure | Discharge Time | Start Voltage/Current | Operating Temperature Range |
GQQ40 / 2.5 | 40L | ≤40kg | 420*480*1250 | 2.5Mpa | ≤8s | DC24V/1.2V | 0℃~+50℃ |
GQQ70 / 2.5 | 70L | ≤70kg | 450*500*1450 | 2.5Mpa | ≤8s | DC24V/1.2V | 0℃~+50℃ |
GQQ90 / 2.5 | 90L | ≤90kg | 480*520*1700 | 2.5Mpa | ≤8s | DC24V/1.2V | 0℃~+50℃ |
GQQ100 / 2.5 | 100L | ≤100kg | 480*520*1700 | 2.5Mpa | ≤8s | DC24V/1.2V | 0℃~+50℃ |
GQQ120 / 2.5 | 120L | ≤120kg | 520*580*1700 | 2.5Mpa | ≤8s | DC24V/1.2V | 0℃~+50℃ |
GQQ150/2.5 | 150L | ≤150kg | 520*580*1830 | 2.5Mpa | ≤8s | DC24V/1.2V | 0℃~+50℃ |
GQQ180/2.5 | 180L | ≤180kg | 520*580*1830 | 2.5Mpa | ≤8s | DC24V/1.2V | 0℃~+50℃ |
For example, a generator room need to use the fm200 / HFC - 227 ea
of seven fluorin propane as fire prevention solutions; If you use a
cabinet type, so we only need to use a few cabinet extinguishing
equipment in the room, then they are evenly placed in the room, in
the event of fire, fire extinguishing agent will from cabinet
nozzle (the nozzle at the top of the rack) in the discharge direct
fire, installation is convenient; If you use the pipe type fire
extinguishing system, you may need to separate a gas cylinder
storage (cylinder), and then put these cylinders in gas storage
chamber (cylinder), and then use the pipeline network connect it to
the ceiling of the room, and set up dozens of nozzle on the ceiling
of the room. Obviously, the cabinet type has its own advantages and
the piping system is not.
In China, the cabinet type has been recognized by the market, and
the China fire protection association is highly recommended, we
also think that it will gradually be recognized in the
international market and recommend.
So far, from Bangladesh, South Africa, Nigeria, Brazil, the united
Arab emirates, Vietnam, myanmar and other places of some customers
also because in the project use the tripod machine cabinet of HFC -
227 ea fire extinguishing system, all equipment after installation
give a high evaluation, they think it is an innovation.
About Dingya
GUANDONG Ding Ya Fire Equipment Co., Ltd. (Called “Ding Ya”),is a
Professional Fire Extinguisher manufacturer for more than 10
years.The company which is registered and approved by the Chinese
Government is situated at No.3 Dongjing Road,Donghuagongye
Village,Renhe Town,Baiyun District,Guangzhou,China.We insist on
“Excellent Quality,Perfect Service and Practical price”.
All our products are made according to National and International
Standard and are regularly inspected by the Quality monitoring and
testing centre for Fire extinguishing ,such as Chinese Government
CCC Certificate,EU CE Certificate and ISO9001:2015 Quality
Management System.
"Work hard with honesty" is our working attitude and basic
principles.We summarized our Enterprise Spirit as
"Struggle,Innovation,Harmony and Development,Honest,Gratitude,Unity
and Love".WE won several National and International awards and
recognition.We have agents from all over the world and we welcome
new agents and partners to work together with us to contribute in
the Fire Extinguisher Industry.
The main characteristics of the cabinet-type heptafluoropropane
fire extinguishing device are high fire extinguishing efficiency,
fast speed, easy installation of engineering projects, space
saving, economical and practical, and no special bottle storage
room is required.
The cabinet type heptafluoropropane fire extinguishing device is
composed of heptafluoropropane cylinders, container valves,
electromagnetic drive devices, connecting pipes, pressure signals,
nozzles and other components. The product has passed 3C compulsory
certification
Note: gas fire alarm system including: gas fire control host, smoke
detector, temperature detector, gas lamp, manual call button or
deflated lights, maintenance switch, fire alarm and ventilation
equipment, etc.
1.2 system installation
Cabinet extinguishing system installation location shall meet the following requirements:
(1) the environment temperature 0 ℃ ~ 50 ℃, and a dry, well ventilated;
(2) must not contain any explosive, conductive dust in the air and corrosion parts of harmful substances, otherwise must be preserved, device shall not by vibration and impact;
(3) the whole cabinet put oneself in another's position must be able to install a smooth, not allowed to tilt;
(4) when fire protective zone should be kept closed condition, other than the pressure mouth opening, and for the protection of the ventilator and fire damper in the ventilation pipe, the discharge of seven fluorin propane before, should be close;
(5) when equipped with outside elastic door closers or clicks, if its open mouth area of not less than the pressure calculation area, not the set pressure.
(6) is installed in the position in the protective zone should be chosen to avoid close to the heat source and direct sunlight exposure, and close to the wall installation. Nozzle jet direction should be toward the protection zones.
When the system installation, should be conducted in accordance with the following order: place the cabinet put oneself in another's position specified in the protected area.
Extinguisher bottle group to be included in the cabinet put oneself in another's position, the position and centered between the into can not produce too big impact, shall not make bottle group of dumping.
With coupling nut connecting piping components and bottle container valve outlet, pay attention to the container valve outlet connections need to coupling nut screw onto a tube (the left-hand thread) on the road, screwing in depth for connecting pipe sealing circular arc surface and the right end of coupling nut thread bottom basic coincidence, then the right end thread and container valve outlet connections (hand tighten) of seven fluorin propane before, should be close;
(5) when equipped with outside elastic door closers or clicks, if its opening area of not less than the pressure release
Mouth computing area, and not the other set pressure.
Observe whether the nozzle tube and cabinet put oneself in another's position of nozzle hole is, if not is adjustable connecting hoop for, at the same time pay attention to the direction of connecting hoop pressure switch on, must not make the direction of the pressure switch is before or after, regulating and fasten the pipeline in the component.
Connect the nozzle tube do auxiliary seal processing (tie ribbons or the sealing glue) and install the nozzle. Fine-tuning extinguisher bottle set position, and make it on the cabinet put oneself in another's position in the back wall and.
Installation of hoop and link up with the fixed bottle groups.
Wrench tight coupling nut.
Install pressure switch do auxiliary seal after processing to the pressure switch seat; And the electromagnetic drive installed on the container valve, locked cupboard door. Installed.