Product Details
Ultra Slim 50 Watt 24V 60000 lumen LED Security Flood Light
50w led flood light 24VDC 8 differents beam angle 170lm/w 4000K
waterproof IP66
High output lighting made for you
With LCD-CESP STE-FL LED site & area and floodlight luminaires,
high output lighting doesn’t have to mean high energy and
maintenance costs. STE-FL provides your outdoor area with bright,
uniform illumination while slashing energy and maintenance costs
compared to traditional lighting technologies.
Energy savings | Modular housing | Control functions |
LCD-FK brings the intrinsic energy savings of LED technology, which lowers utility bills and reduces payback periods. These long-lasting luminaires also require less frequent maintenance, decreasing costs even further compared to traditional HID technologies. | LCD-FK modular housing provides a full range of scalable solutions in one family, allowing you to use only what you need. Additionally, with industry leading high output illumination of over 95,000 lumens, you can potentially use fewer luminaires compared to HID. | LCD-FK programmable dimming, motion response, preplanned maintenance and other control functions further optimize energy savings and extend the luminaire’s life while maintaining a sense of security throughout your site. |
Now you can instill a sense of security and attract attention in
any large area or floodlighting application without the hassle of
frequent relamping or high utility bills.
Specification
Product Number | LCD-FK-055 | LCD-FK-085 | LCD-FK-105 |
Rated Power | 50W | 80W | 50W |
Lumen (lm) | 6000 | 9600 | 12000 |
Rated Voltage | 90-305VAC |
Power Factor | >95 |
Color Temperature | 3000 / 4000 / 5000 / 6000K |
CRI (Ra) | >75 |
IP Rating | IP65 |
LED Chip | LUMILEDs SMD3030 |
Driver | Meanwell/philips |
Lifespan | >50,000hr |
Housing Material | Aluminum |
Operating Temperature | -30°C~ 50°C |
Beam Angle | 60°/ 90°/ 120° |
Warranty | 5 years |
Certification | CE -RoHs-SAA |
CAUTION
RISK OF PRODUCT DAMAGE
- Never connect luminaires and/or components under load with supply
voltage turned on.
- Do not mount or support these luminaires in a manner that can cut
the outer jacket or damage wire insulation.
- Do not restrict fixture ventilation. Allow for some volume of
airspace around luminaire. Avoid covering luminaire with
insulation, foam or other material that will prevent convection or
conduction cooling.
- Do not exceed luminaire maximum ambient temperature.
- Do not modify the luminaire.
- Only use luminaire in its intended application and location.
- Led products are polarity sensitive. Ensure proper polarity before
installation.
- Electrostatic Discharge (ESD) can damage LED. Personal grounding
equipment must be worn during all installation and servicing of the
luminaire.
- Do not touch individual electrical components as this can cause
ESD, shorten LED life, or impact LED performance.
- Always read the luminaires complete installation instructions prior
to installation for any additional luminaire specifific warnings.
- In the case of HID or Fluorescent luminaires, regular re‐lamping is
required to keep luminaire operating within safe limits
- Do not install damaged product. Handling and installing damaged
products can potentially increase the risks mentioned In case of
damage and/or missing parts upon arrival of the luminaire, please
contact us.
- These instructions do not purport to cover all details or
variations in equipment nor to provide every possible contingency
to meet in connection with instal‐lation, operation or maintenance.
- Please see luminaire specifific Installation and Maintenance
Instruction for additional warnings or any applicable LCD or
regulatory statements. Failure to follow any of these Instructions
could void luminaires warranties.
Luminaire Maintenance
- Regular luminaire maintenance programs are recommended.
- It is recommended to clean the outside of the luminaire and the
refractor/lens.
- Frequency of cleaning will depend on ambient dirt level and minimum
light output which is acceptable to user.
- If clean water is not sufficient for cleaning, use a neutral,
synthetic, not‐scratching and not‐abrasive cleaning substance.
- Never use alkaline and/or acetous cleaning substances.
- Make sure that the cleaning substance is carefully removed by
rinsing with lots of clean water.
- LCD recommends using a cleaning solution that has a PH between 5
and 8.
Product Photos:
Company Profile
LCD-CESP is the leading innovator in Lighting design.
We strive to offer the best service to our customers
Our lighting products are market leaders and have many unique
features.
We offer a minimum of 5 years warranty.
Most of all Customer satisfaction is our priority.
Our R+D team have many years in the lighting Industry and we offer
the following skills to our customers-
Mechanical design
Electronic design
Optic testing
We are sourcing components to the highest specification.
Our manufacturing and assembly processes are to ISO 9001 and ISO
1400 requirements.
We offer customisation and design services.