100kW Cummins Engine Super Silent Diesel Generator Set 68dBA For Hospital

Brand Name:Hosem Power
Certification:CE/ISO9001
Minimum Order Quantity:1 SET
Delivery Time:30 days
Payment Terms:L/C, T/T
Place of Origin:CHINA
Contact Now

Add to Cart

Verified Supplier
Location: Fuzhou Fujian China
Address: Rm526, C2 Building, Cangshan Wanda Plaza, No. 216 Pushang Road, Fuzhou City, Fujian, China.
Supplier`s last login times: within 36 hours
Product Details Company Profile
Product Details

Super Silent Generator Set, 100kW Diesel Generator for Hospital, 68dBA, 1000L Fuel Tank , Cummins Engine


We manufacture our generator canopies with thicker walls and high-quality sound-absorbing cotton to effectively reduce noise levels. For example, a 100kW generator can achieve noise levels as low as 68dB or below. This makes our silent generators ideal for noise-sensitive environments such as hospitals, schools, and residential areas.


Contact us today to get our best price!


Specification

ModelA-C124H
Standby PowerkVA124
kW99
Prime PowerkVA113
kW90
FrequencyHz60
Output VoltageV240
Oil ConsumptionL/H0.080971713
Dimension For Open-typemm2180 X 820 X 1450
Weight For Open-typekg2900 X 1080 X 1500
Dimension For Soundproofmm75
Weight For Soundprofkg411
Engine Model6BT5.9G2
No.of Cylinder6 Cylinder in line
Boremm102
Strokemm120
DisplacementL5.88
Cooling Fan Air Flowm3/min148
Compress Air Flowm3/min5.8
Exhaust Gas Flowm3/min14
Exhaust Gas Temperature510
Lubrication Oil CapacityL16.4
Cooling Water CapacityL28
Starting VoltageV24
Engine Max.Output PowerkW110
Alternator ModelUCI 274 C
Alternator BrandStamford
Rate OutputkVA125
FrequencyHz60
AltitudeM≤1000
InsulationClass H
Protection GradeIP23
Alternator for choiceWe also have Leroy Somer, Marathon, Mecc Alte and Chinese brand Brushless alternator for your choice.
Control Panel ModelAF500
ControllerDeepsea Brand Model DSE7320
Function of control panelAutomatic genset start/stop
Automatic battery charger
Emergency stop
AMF (Automatic Mains Fault)
Remote control
Micro-processor based design
LED alarm indication and Sound alarm
Display of the controllerGenerator voltage: Uab, Ubc, Uca
Generator current: Ua, Ub, Uc
Generator temp.: ℃/℉ both display
Generator frequency: Hz
Generator power: kW, kVA, kWh, kVAr, kVArh, kVAh
Generator starts count: 999999 times (Max)
Generator pressure: kPa/Psi/Bar both display
Charging Voltage: V
Battery Voltage: V DC
Protection of Diesel GeneratorOver / Under Speed Alarm and Shutdown
Start / Stop Failure Alarm
Over Current Alarm and Shutdown
Under / Over Generator Voltage Alarm and Shutdown
Low Oil Pressure Alarm and Shutdown
High Engine Temperature Alarm and Shutdown
Over Load Alarm and Shutdown
Low and High Battery Voltage Alarm
Lose of Speed Signal Alarm and Shutdown
Charge Fail Alarm


Standard Features


· AVR delivers non-fluctuating power

· Panel type digital control panel

· 24 Volt electric starter ensures easy starting

· Low oil pressure shut down the system

· Low fuel cut out protection

· Low water cut out engine protection

· Enclosed structure ensures quieter operation

· Alternator excitation mode brushless self-excitation

· Three-phase output meets differing requirements

· Four Cylinder, four-stroke, water-cooled diesel engine

· 8 hours running @ full load on a single tank of fuel

· Dual access doors for easy maintenance

· Optional automatic or manual transfer switches available

· ATS ( auto transfer switch for city power and generator power ) / AMF (auto mains failure) /parallel running for option

· Weatherproof and soundproof, enclosure high-grade steel protected by powder coat painting and incorporate internally mounted exhaust silencers

· Noise Level (65-70dBA @ 7m)

· All ratings are at sea level

What are We Advantage?
1: We are More Professional
Most members of Hosem Power have more than 10 years of experience in the generator area, Our mechanical engineers, electrical engineers have more than 20 years of experience in the generator ara. We are always ready to serve to your needs.


2: Outstanding Quality
Our advantage lies in:
1. Good shock absorption performance: Optimal design of shock absorption system based on computer dynamic simulation.
2. Advanced control system: Full monitoring system control strategy found on reliability design.
3. Low noise: Tailor custom-engineered exhaust silencer system for each set.
4. Green environmental protection: Diesel generator set combined energy-saving and low emission in one.


3: Strictly QC Before EX-Factory.
Each and every unit is strictly factory tested before shipment.
1) Parts faults testing
2) Fuel tank pressure testing
3) Bolt tightening torque testing
4) Painting thickness testing
5) Voltage bearing and insulation testing
6) Noise testing
7) Loading Testing: 25%, 50%, 75%, 100%, 110% load to check verify that all control systems, alarm and shut-down protection.

FAQ
Q: Do you offer OEM service?
A: Yes
Q: What is your payment term?
A: 30% T/T in advance, 70% balance when receiving B/L copy, Or 100% irrevocable L/C at sight.
Q: What is your lead time?
A: About 20-30 days after receiving advance deposit or original L/C.
Q: What certificates do you have?
A: We have CE, ISO. And we can apply for specific certificates for different countries such as SONCAP for Nigeria, COI for Iran, SASO for Saudi Arabia, etc.
Q: What warranty do you provide?
A: One year, during the guarantee period, we will supply free of the easily damaged parts for the possible problems except for the incorrect operation. After expiration, we supply cost spare parts for Genset maintenance.
To learn more about Cummins series generator, pls check here: Cummins Diesel Generator | Factory Price from China

China 100kW Cummins Engine Super Silent Diesel Generator Set 68dBA For Hospital supplier

100kW Cummins Engine Super Silent Diesel Generator Set 68dBA For Hospital

Inquiry Cart 0