Duplex ST To SC 0.9mm 2M Multimode Fiber Optic Patch Cord

Brand Name:Geehe
Certification:ISO9001:2015,ISO14001,RoHS,CE
Model Number:GH-OP-0017
Minimum Order Quantity:300 pcs
Delivery Time:With 5-7 working days after confirmed the order
Payment Terms:T/T, L/C, D/A, Western Union,Cash
Contact Now

Add to Cart

Site Member
Location: Wuhan Hubei China
Address: Optical Valley Industrial Park, Wuhan, China
Supplier`s last login times: within 1 hours
Product Details Company Profile
Product Details

High Return 0.9mm Riser Rated (OFNR) 2M Duplex SC To ST Multimode Fiber Patch Cord


1.Basic Introduction:


SC to ST Fiber Optic Connector is a snap-in connector fiber also with a 2.5 mm ferrule that is widely used for it Is excellent performance. It Is a snap-in connector that latches with a simple push-pull motion. It is also available in a duplex configuration, the durable rubber boots protect against damage typical in busy data racks and each end is properly labeled for easy identification.


The cable has ST to SC connectors, a PVC jacket, and is FDDI and OFNR rated. Duplex multimode fiber is most commonly used in LAN applications.



2. Patch Cord Benefit & Features:


  • Attenuation loss meets or exceeds the latest industry standards
  • Simplex, duplex or multi-fiber assemblies
  • High precision zirconia ceramic ferrule protected by dust cap
  • Low insertion loss, high repeatability, and stability
  • Premium connector with ORL ≥ 55dB for UPC and 65dB for APC
  • Operating temperature in compliance with IEC 61753-1

3.Fiber Optic Patch Cord Applications:


  • Optical Fiber Communications, Video, LAN, CATV Systems

  • Optical Access Network

  • Fiber Optic Data Transmission

  • Data Centers

  • Local Area Network

  • Test Equipment


4.Specification&Technology Parameter


ParametersValue
Connector TypeLC/UPC,LC/UPC
Center Wavelength(nm)1310 or 1550
Max.Insertion Loss(dB)0.3
Min.Extinction Ratio(dB)23
Min.Return Loss(UPC) (dB)50
Min.Return Loss(APC) (dB)60
Key OrientationSlow Axis
Axis Alignment(deg)±3
Operating Temperature(℃)-20~+70
Storage Temperature(℃)-40~+85
FIber TypePM Panda Fiber


* For Device with connector.IL is 0.3dB higher,RL is 5dB lower,ER is 2dB lower.

* The default connector key is aligned to the slow axis.


5.SC Connector Specification& Technology Parameter​:


ParameterUnitIndex
End-Face TypePCUPCAPC
ILdBSM: ≤0.3, MM ≤0.1
RepeatabilitydB≤0.1
interchangeabilitydB≤0.2
RLSMdB≥50≥55≥65
MMdB≥36(Without APC connector)
Mating Times1000
Operating Temperature-40~ +80

6. LC Connector Ordering Information:


OFC-X-XX-XX-XX-X-X
S: Simplex
D: Duplex

SA:LC/APC

SC:LC/UPC

SP:LC/PC

SA:LC/APC

SC:LC/UPC SP:LC/PC

09:0.9mm 20:2.0mm 30:3.0mm0:G652D 1:G657A 2:50/125 3:62.5/125 4:others0.5:0.5m
1.0:1.5m
10:10.0m
Fiber ModeConnector TypeConnector TypeCable DiameterFlange TypeFiber Length

* EX: OFC-SC-SC-09-1-0.5


7. How to choose Fiber patch cords?


1) Fiber Cable Mode: Single Mode or Multimode

The mode of fiber patch cables indicates how light beams travel within the fiber. There are two fiber cable modes: single mode and multimode.

2) Number of Fiber Strands: Simplex or Duplex


According to the number of fiber strands, there are simplex and duplex fiber patch cord. As shown in Figure 2, simplex fiber patch cord contains one single strand of fiber with one simplex connector on each end. It can be linked with a pair of BiDi transceiver modules featuring with one port. Whereas duplex fiber patch cord consists of two strands of glass or plastic with one duplex connector (or considered as two simplex connectors). It is often linked with common transceivers or dual fiber BiDi transceivers.


3) Choose the Right Cable Jacket Type (PVC/LSZH/OFNP/Armored)


Usually, there are three cable jacket types: Polyvinyl Chloride (PVC), Low Smoke Zero Halogen (LSZH) and Optical Fiber Nonconductive Plenum (OFNP). You can see there features in figure below and choose the right one for your network.


4) Choose the Right Connector Polish Type (UPC/APC)


Since the loss of the APC connector is lower than UPC connectors, usually, the optical performance of APC connectors is better than UPC connectors. In the current market, the APC connectors are widely used in applications such as FTTx, passive optical network (PON) and wavelength-division multiplexing (WDM) that are more sensitive to return loss. But APC connector is usually expensive than UPC connector, so you should weigh the pros and cons. With those applications that call for high precision optical fiber signaling, APC should be the first consideration, but less sensitive digital systems will perform equally well using UPC. Usually, connector color of APC patch cable is green, and of UPC patch cable is blue.



China Duplex ST To SC 0.9mm 2M Multimode Fiber Optic Patch Cord supplier

Duplex ST To SC 0.9mm 2M Multimode Fiber Optic Patch Cord

Inquiry Cart 0