Germicidal Lamp Four Indicator Lights 40W PCB UV Board

Brand Name:Senkong
Certification:CE
Model Number:TLD545
Minimum Order Quantity:500
Delivery Time:5-7 working days
Payment Terms:T/T, Western Union
Contact Now

Add to Cart

Active Member
Location: Dongguan Guangdong China
Address: 4th Floor, Factory No. 2, Botou Industrial Zone, Botou Village, Chashan Town, Dongguan City
Supplier`s last login times: within 35 hours
Product Details Company Profile
Product Details

220V Four Indicator Lights Disinfection Lamp PCBA Circuit Board Germicidal Lamp


Specification


IInput powerAC 220V 40W about 0.181A
Output parametergermicidal lamp 36W
Drive typeRelay
Measurement accuracy requirementtime accuracy 5%
Man-machine interface displayfour indicator lights, one red and three green
Man-machine interface input

one touch spring, control switch and file selection

Input and output interface typeVH3.96-2PIN-DIP
Applicationkindergartens, offices, parks,etc

Description


It has single touch button: TP, four indicators: D1 (switch indicator), D2 (15min working indicator), D3 (30min working indicator), D4 (1h working indicator)


At the initial power-on, only the D1 indicator is on, but the germicidal lamp and other indicators are not on.


Operation


In non-working state, press the TP key to select the working time of the germicidal lamp. Every short press (key duration <3S), the TP key changes in sequence along [15min-30min-60min], and the cycle time is within 3S.


Re-selection, at the same time, the D1 indicator is off, the indicator corresponding to the selected working time lights up; after 3S waiting, the indicator of D1 and the corresponding working time flashes, and the buzzer sounds 10 times once per second, and the sterilization lamp starts after 10S Lights up, at the same time D1 and the corresponding work indicator light are always on.


Application


Disinfection and sterilization in kindergartens, offices, parks, family rooms, and balconies and hotels.


Quality inspection


1. Appearance inspection: Check the installation and welding of the original

2. Component push pull test: use push pull meter to check the welding and fastness of components

3. Rigorous testing: Each product must be tested before it can be shipped.


Package


1. Anti-static bubble film shall be used for packaging and packing after piecing together

2. Matters needing attention when packing

1) Considering the force comprehensively, the direction set up after PCBA packing should be the same as that of corrugated carton

2) Avoid the collision between PCBas during packaging; Appropriate placement and bubble film thickness should be selected

China Germicidal Lamp Four Indicator Lights 40W PCB UV Board supplier