Fire Safe Design Cryogenic Valve For LNG Storage

Brand Name:coosai
Certification:API6D, ISO 9001
Model Number:Q41,47F/Y, Z40Y, H76Y
Minimum Order Quantity:1SET
Place of Origin:CHINA
Packaging Details:PLYWOOD CASE
Contact Now

Add to Cart

Active Member
Location: Wenzhou Zhejiang China
Address: Dongou Industrial Zone, Oubei Town,Wenzhou,Zhejiang,China
Supplier`s last login times: within 26 hours
Product Details Company Profile
Product Details

Cryogenic Gate Valve -198 Deg C


Technical Summary


Szie Range: 1/4"~24"(DN6~DN600)


Pressure Range: 150LB ~ 2500LB, PN10~PN64


Application: Air separation plants, LNG storage and distribution, LNG Transportation, Liquid and Gaseous Oxygen for steel production, Etc.


Series in Range: Standard bore, reduced bore; Ball valve, Gate valve, Check Valve, Globe valve, Etc.


Temperature Range: -196 Deg C


Standards: API 6D, API 607 for fire safe design, API600 / API603 for Gate valve, BS 1873, BS1868, Etc.


Material: Austenitic Stainless steel, ASTM A351, ASTM A182, Etc.


Operation: Lever / Handwheel, or gear operated, Pneumatic or Electric Actuated. Etc.


End Connections: RF, RTJ. FF, Butt Welded, Extended Butt Welded, Etc.


Cryogenic Definition:

Low-temperature parts into liquid nitrogen tank insulation a certain length of time, to reduce its due to temperature differences andmetallographic changes resulting from the deformation,which increases when the low-temperature valve sealing performance of a processing method.


Cryogenic method: soak the parts to be processed into liquid nitrogen tank for cooling, when parts of 196 degrees centigrade temperature reaches-, start insulation 1 ~ 2 hours, then remove the carton natural treatment to room temperature, repeat cycle twice.


Austenitic stainless steel in Martensitic transition temperature, part of austenite into martensite changes causing the resulting volume parts deformation is an important reason for the valve sealing surface leakage. Moreover, as the temperature decreases parts produces shrink and thermal stress caused by the valve irregular parts of deformation caused by low leakage is also one of the reasons. To this end, before finishing of parts (e.g. sealing surface grinding) on main parts such as: the valve body, valve covers, plate (disc), the valve stem fasteners such as below the operating temperature of cryogenic treatment.


As a general rule, use of the valve below 101C, before finishing the main part for cryogenic. But if the user requires, above-101.C working temperature valve parts for cryogenic.





China Fire Safe Design Cryogenic Valve For LNG Storage supplier

Fire Safe Design Cryogenic Valve For LNG Storage

Inquiry Cart 0