Two Stations IEC 60884-1 Plug Socket Test Equipment For Breaking Capacity

Brand Name:HeJin
Certification:calibration certificate (cost additional)
Model Number:HC9914B/HC9915A
Minimum Order Quantity:1 set
Delivery Time:30 days
Payment Terms:L/C, T/T
Contact Now

Add to Cart

Verified Supplier
Location: Guangzhou Guangdong China
Address: No.6-36, Yaogu Farm, Shibi No.3 Village, Shibi Street, Panyu District, Guangzhou, Guangdong, China
Supplier`s last login times: within 23 hours
Product Details Company Profile
Product Details

Two Test Stations IEC 60884-1 Plug Socket Test Equipment For Breaking Capacity


Standard:

IEC 60884-1 ‘Plugs and socket-outlets for household and similar purposes – Part 1: General requirements’ clause 20, clause 21 and figure 16;

IEC 60669-1 ‘Switches for household and similar fixed electrical installations – Part 1: General requirements’ clause 18, clause 19.


Application:

It is applicable for the switches breaking capacity and normal operation life test of household and similar fixed electrical installations, also suitable for plugs and sockets’ breaking capacity and normal operation life testing of the household and similar purposes. Plug Socket Test Equipment


Test sample:

The test equipment can do endurance testing for button switch, rocker switch, toggle switch, rotary switch, plug and socket.


Feature:

The test machine is made of aluminum frame, stainless steel seal plate, driven by the servo motor and ball screw, with 7-inch color touch screen, PLC control system, humanized operation interface and powerful digital display. The test times, conduction current time, test speed, test stroke can be preset. It has the electric current display function that can show the sample’s conduction current. The whole test machine has 2 working stations, one station can process linear switches and plugs and sockets, and one station can process rotary switch, the two stations are independent control. When there are continuously switched on or off due to the adhesion or failure, it will alarm and record the appropriate test times, and it alarms when the test times reach the preset value. The test machine will automatically stop when an alarm occurs.

Coupled with the external load bank (resistive, inductive and capacitive) can process loading test, it has a corresponding control system.


Parameter:

SWITCH PLUG SOCKET ENDURANCE TESTER HC9914B
PowerAC220V, 50Hz(customizable)
Work station

2 Stations:

1 liner stations: Can test button switch, rocker switch, toggle switch, plug and socket.

1 rotating stations: Can test rotary switch.

work independently

Operation interface7-inch touch screen
Drive modeServo motor
Control systemPLC control. Plug Socket Test Equipment
Test times0~999999 times, can be preset
Conduction time0~999.9s, can be preset
Break time0~999.9s, can be preset
Test stroke

Linear:0 ~ 100mm, adjustable

Rotate: 0-360., adjustable

Test speed

Linear:10 ~ 200mm/s, adjustable

Rotate: 0-360./s, adjustable

Test environment

Atmospheric pressure 80 ~ 106kpa;

Ambient temperature 5~ 40℃; Relative humidity (20~ 90)%RH; Use place: no violent shaking, no vibration, no electromagnetic interference, no dust, no explosive or corrosive gas, good heat dissipation

LOAD BOX HC9915A
Power SupplyAC220,50Hz.
Voltage VRange 0 ~ 300V accuracy ± 0.5% ± 2d
Current ARange 0 ~ 30A accuracy ± 0.5% ± 2d
Power KWRange 0~20KW, accuracy±05%
Power FactorRange 0.3 to 0.999 accuracy ± 0.5% ± 2d
Load SelectionResistive, Inductive and Capacitive load three in one, switchable
Capacitance Selection70uf, 140uf, 73uf optional
Output ModeEach power, Interval power optional
Count/Preset0~999999 times, can be preset
Load power capacity2*10KVA
Output current limit30A, the load will be automatically cut off when over 32A
Output voltage limit300V, the load will be automatically cut off when over 320V

China Two Stations IEC 60884-1 Plug Socket Test Equipment For Breaking Capacity supplier