Flammability Test Chamber UL1581 Flame and Tests FTI And VW-1


Standard:

UL1581 ‘Reference Standard for Electrical Wires, Cables, and Flexible Cords’ flame test.


The UL 1581 is an internationally recognised standard test for evaluating fire safety for electric cables. The FTT UL 1581 test for flammability of cable materials gives a preliminary indication of their suitability for a particular application. The apparatus is supplied as a complete system incorporating all the features necessary for ease of use and safety. It conforms to UL 1581 vertical specimen Bunsen Burner tests and associated international standards. These are:

1060. Vertical Flame and FT1 Tests

1061. Cable Flame Test

1080. VW-1 (Vertical Specimen) Flame Test

1090. Horizontal-Specimen Appliance-Wire Flame Test

1100. Horizontal-Specimen / FT2 Flame Test


UL 1581 VW-1This was the first flame test developed for studying how flames spread on wire and cable. The test is performed with a 24′ wire and a Tirrill burner. Two clamps hold the single sample vertically. The burner is mounted at a 20° angle and applied for 15 seconds, then reapplied four more times each time the wire stops burning. If the sample doesn’t burn more than 60 seconds after any of these burning sessions, or if less than 25% of the indicator flag burns, or the cotton batting is ignited during the test, the wire passes. A “tray rated” cable must pass this test as well. Flammability Testing Equipment


Parameter:

Working voltage220V/50Hz
Control operation modePLC control, 7 inch color touch screen operation, with infrared remote control
Blast burner standardANSI/ASTM D 5025, diameter:9.5mm ± 0.5mm, length:100mm, made of brass
Gas flow

Vertical test: 965±30ml/min or 117±3 mm;

Horizontal test:440±10mL/min or 58±1mm,

Flow meter adjustment

Gas pressure0.1MPa
U type pressure gauge back pressure water column height

Vertical test:125±10 mm;

horizontal test:45±5mm

Combustion time / residual glow time9999X0.1S. Flammability Testing Equipment
Combustion angle0°, 20°, 45°, Adjustable
Test flame calibrationTemperature measuring copper head:Ф9mm±0.01mm, weight before drilling:10 ± 0 .05g
Thermocouple: The American original Omega φ0.5 armour nickel-chromium/nickel aluminum wire K-Thermocouple, temperature resistance 1100°

Distance between the bunsen burner port to temperature measuring copper block:

Vertical test: 55±1 mm;horizontal test: 25mm

Flame height:

Vertical test: Inner flame:40±2mm, Outer flame: 125mm;

horizontal test: Inner flame:16.5±1.5mm, Outer flame:50±4mm

Temperature rise time from 100±5°C to 700°±3°C

Vertical test: 54±2S; horizontal test: 84±2s

Gas categoryPurity>98% methane

China UL1581 0.1MPa 220V Flammability Test Chamber supplier