If the tablet weight difference is found to increase during
tableting (referring to the weight difference of the tablets),
exceeding the limit specified in the pharmacopoeia, the reasons and
treatment methods are as follows:
① Punch lengths are different, which can easily lead to an increase
in tablet weight difference. Therefore, it must be checked with a
vernier caliper before use. If the filling position of individual
lower punches does not match the filling position, resulting in a
reduction in the filling amount of particles, the obstruction
should be cleared. .
② The different positions of the hopper will cause differences in
its performance, resulting in different falling speeds of
particles, resulting in differences in the filling amount of the
inner die holes.
③ The particle thickness is different, resulting in different
accumulation weights in the feeder. Too much fine powder, excessive
particle moisture and insufficient lubricant can cause changes in
tablet weight. The particle quality should be improved.
④The reason for the change in tablet weight is generally caused by
the malfunction of the tablet press or the negligence of the work.
Therefore, during the tablet pressing process, the machine parts
should be well maintained, and the machine parts should be
inspected in detail for damage, and every Weigh the tablets at
regular intervals (10-20 minutes) and make sure the tablets are
within the specified weight.