100L Lab Chiller Unit Air Cooled Glycol Chiller R404 Refrigerant


Parameters of Chiller


Product NameChiller
Product ModelDLSB 200L-40℃
Non-Loaded Minimum Temperature-40℃
Temperature Fluctuation±2℃
RefrigerantR404
Cooling Capacity390W – 22600W
Machine Power8640W
Circulating Power280W
Flow Rate of Circulating Pump (Optional)35L
Lift (Optional)11M
Ambient Temperature≤ 25℃
Ambient Humidity≤ 70℃
Power Supply220V/60Hz (Three Phase)
Working Current40A

Description of Chiller


The low-temperature cooling circulating pump of this equipment adopts microcomputer intelligent control system. The low-temperature cooling liquid circulating pump provides low-temperature circulating cooling water (liquid) flow or low-temperature constant-temperature water (liquid) flow to meet the needs of cooling water and Low temperature liquid cooling or constant temperature equipment, such as rotary evaporator, fermentation tank, electron microscope, low temperature chemical reaction kettle, electron energy spectrometer, mass spectrometer, densitometer, freeze dryer, vacuum coating instrument, reaction kettle, etc.


Working Principle of Chiller


The low-temperature cooling circulating pump of this equipment adopts microcomputer intelligent control system. The low-temperature cooling liquid circulating pump provides low-temperature circulating cooling water (liquid) flow or low-temperature constant-temperature water (liquid) flow to meet the needs of cooling water and Low temperature liquid cooling or constant temperature equipment, such as rotary evaporator, fermentation tank, electron microscope, low temperature chemical reaction kettle, electron energy spectrometer, mass spectrometer, densitometer, freeze dryer, vacuum coating instrument, reaction kettle, etc.


Troubleshooting


First pay attention to whether the boot sequence is correct

Confirm that the refrigerant used is correct. In most cases, ethanol solution with a content of more than 97% is required (do not use automobile antifreeze as the refrigerant, as it will damage the life of the circulating pump if it takes a long time).

The filling of the refrigerant should be kept at the same level as the coil in the liquid storage tank, but not too much or too little (too little will affect the cooling effect of the refrigeration pump);

Confirm whether there is fluorine in the compressor: ≥30L

It should be noted that it is forbidden to add any refrigerant to the cold storage device when the temperature of the refrigerant is reduced to the set value by the refrigeration pump.

The condenser needs to be cleaned when the pump is slow or poorly refrigerated (clean the condenser of the pump at least once a week to prevent clogging to prevent the refrigeration pump from being blocked by the condenser and causing the heat to be unable to remove the compressor and causing the compressor to burn)


Precautions for Use


1. Check whether the inlet and outlet valves of the equipment are normally opened and the pressure is within the normal range.

2. Check whether the power of each device is in the on position.

3. Before using the low-temperature coolant circulation pump, add ethanol with a refrigerant concentration of ≥97% to the tank, and the liquid level of the medium should not pass the refrigeration coil in the tank.

4. Check the power supply: the power of the power supply should be greater than the total power of the instrument, and the power supply must have a good "grounding" device;

5. The equipment should be placed in a dry and ventilated place, with no obstacles within 500mm around the instrument;

6. Pay attention to the position of the liquid level in the tank. When the liquid level is too low, add refrigerant medium in time

7. When the equipment is working, the temperature of the inlet and outlet pipes is relatively high, so be careful not to touch them to prevent frostbite;

8. After use, all switches are turned off and the power supply is cut off;

9. Clean the condenser regularly to avoid the reduction of product efficiency due to excessive dust;



Our Service


Pre-Sale Service:

Provide 24-hour technical consultation and reply;

Provide professional quotation information;

Provide detailed product performance specification;

According to product's using condition, technicians will offer rationalization proposals to assist clients to select proper product types;

Provide other corollary equipment according to client requirements.

In-Sale Service:

With supervision from the source of products, the qualified rate of raw materials entering the factory can reach 100%;

Whole manufacturing process are in strict accordance with promised procedure requirements, product qualified rate can reach 100%;

Provide product's inspection record of key junctures to customers;

Provide production schedule photos to customers at regular intervals;

Package and transport of products are in strict accordance with the export standard;

Provide transportation schedule information to clients timely.

After-Sale Service:

Provide targeted installation video;

Under the premise of correct installation, normal maintenance and using, we guarantee one-year warranty period;

When warranty period has expired, our sold products enjoys lifetime guarantee repair, we only charge cost price for changing product's standard component and sealing component;

During installation and adjustment period, our after-sale service staff will communicate with customers frequently to know product's running state in time. Assist customers to install and adjust products until customers are satisfied;

If product has malfunction during operation period, we'll offer you satisfied answer in time. We'll reply you within 1 hour and provide solution or send staff to spot within 24 hours after receiving maintenance notification;