1. Power quality problems


Common power quality problems in the world power applications include harmonics, three-phase asymmetry, notch, voltage flicker, resonance transient, impulse transient, voltage transient, noise and so on. Among them, harmonic and voltage transient are the two most prominent power quality problems. The annual economic losses caused by power quality disturbance and electrical environmental pollution are astonishing.
The EPRI report of the American Academy of Electric Power Sciences points out that losses caused by harmonics and other power quality problems in the United States are as high as $30 billion a year. In China, according to the data of "China Power Quality Industry Status and Customer Behavior Survey Report" among the 92 enterprises in 32 industries surveyed, 49 enterprises suffered economic losses of 250-350 million yuan due to power quality problems.
At present, the international electricity utilization rate is about 56%, while our electricity utilization rate is only about 35%. The important reason is the low power quality. If the power quality is improved on a large scale to improve the efficiency of power utilization, it will play a very important role in energy saving and emission reduction.
2. Total Solution

Intelligent electric power saving system


Without changing the original production structure, production equipment and production technology of enterprises, SEBOS intelligent power saving system is installed at the low or high voltage terminal of transformers. Using pure physical electromagnetic interaction mode, eliminating clutter, absorbing harmonics and improving power factor in power supply, so that can balance electromagnetic interaction, reduce magnetic moment imbalance, improve mechanical efficiency of motor and improve power quality.

3. Technology Princip


Electromagnetic balance technology / Micro magnetic field technology / Virtual capacitance technology


The core technology of SEBOS Intelligent Power Saving System is a three-phase electromagnetic balance technology with iron core and special multi-winding connection mode. Its iron core adopts anti-Z connection, balances three-phase voltage and current, balances three-phase power supply and eliminates clutter interference by overlapping magnetic fields produced by three-phase windings.

Special multi-winding connection mode can compensate magnetic flux of iron core and control the consistency of induction electromotive force of each phase to the greatest extent, so as to maintain three-phase balance, reduce additional losses such as zero-line current, and achieve the purpose of power saving.


4. Technical Comparison with energy-saving products on the market


Feature typesReactance TechnologyReactive power compensationFrequency conversion technologyPhase control technologyOperation managementSEBOS Intelligent power Saving System
PrincipleStep-downReduce reactive powerPWM controlPhase controlled voltageEfficiency managementElectromagnetic Balance Technology
CapacityMiddle,smallNot limitedMiddle,smallMiddle,smallNot limitedNot limited
Installation modeSeries connectionParallel connectionSeries connectionSeries connectionSeries connection
Higher harmonicRestrainRestrainIncreaseIncreaseReduce
Power factorReduceIncreaseIncreaseReduceIncrease
Three-phase BalanceNoNoNoYesYes
MaintenanceNoSome timesAlwaysAlwaysAlwaysNo
Using life20 years8 years2-5 years3-8 yearsOver 30 years
ApplicationLighting deviceSystem and Single deviceSingle deviceSingle deviceSystemSystem
Structure conditionSimpleComplexSimpleSimpleSimple
Electricity saving ratelittlenoHighlittlenoHigh
Energy savinglessnolesslesshighHigh
DisadvantageMainly used for lightingOnly reduced the loss of the power supplyLarge maintenance and high harmonic generationSame as frequency conversion technologyIt is difficult to establish control modelOn-site testing before customization

5. Personalized customized


Single-phase: 110V, 220V 50A Medium and low pressure: 30KVA-2500KVA


Three-phase: 380V,6KV,10KV,35KV 5000A High pressure: 3150KVA-5000KVA


Capacity (KVA)SIZE: L (mm)SIZE: W (mm)SIZE: H (mm)Weight
315100011002000550
400100011002000650
500100011002000750
630100011002000900
8001000110020001000
10001000110020001100
12501000110020001250
16001000130020001450
20001100130020001650
25001100130020001850
31501300130020002000

6. Equipment inspection


1) Passed the qualification inspection of CNAS

2) According to CQC3103-2009

7. Equipment safety and energy saving


  • SEBOS intelligent power-saving system will not be cut off due to switch tripping

  • When the intelligent power saving system fails, the main circuit will automatically switch to the municipal power supply.

  • The load is not affected during power saving and normal electric supply conversion and the modular design of power-saving part is convenient for upgrading

  • Intelligent power saving system is installed at the secondary outlet side of transformer, which conforms to the electricity regulations.

  • SEBOS intelligent power saving system is sent to the National Smart Grid Transmission and Distribution Equipment Quality Supervision and Inspection Center and China Quality Certification Center for inspection and certification, and has obtained CMA, CE and CQC reports.


8. Reconstruction effect


Before reconstruction

After Reconstruction


9. Successful cases




China 380V Intelligent Power Saving System supplier

380V Intelligent Power Saving System

Inquiry Cart 0