16MM2 - 800MM2 AAC Conductor In Power Transmission Lines


Application:

Overhead transmission and primary and secondary distribution.


Applicable Standard:

IEC61089, ASTM B231, AAC BS215


Construction:

Aluminum 1350-H19 wires, concentrically stranded



Conductor (AAC and ACSR) have been widely used in power transmission lines with various voltage levels, because they have such good characteristics as simple structure, convenient installation and maintenance, low cost, large transmission capacity. And they are also suitable for laying across rivers valleys and the places where special geographical features exist.

2. Service Performance

(1).The permissible long-time operating temperature for aerial conductor is 70oC.

(2).Under the circumstance that rare climate occurs and high ice coverage rate, the biggest stress of cable at the lowest point of the sag should not exceed 60% of the short-time destructive power.

(3).When connecting conductors, the conductor beside the connecting tube can’t be prominent. Otherwise, the force on the operating conductors will be unbalanced. After connectors are installed, the connecting tube should be painted by moisture-proof varnish in order to protect it from corrosion.

(4).Under installation, the arc downing stress of all the conductors should be the same. With in the permissible distance of crossing buildings or dropping to the ground, the stress can be 10-15% higher than regular stress.

We can supply this conductor according to different recognized standards, such as IEC61089, BS215, BS EN 50182: 2001, STM B231, CSA C49, DIN480201, JIS C3109, customer special specification also can be satisfied.

Nominal

area

Stranding &wire diameterApprox Overall diameterBreaking LoadDC Resistance at 20

Approx.

Weight

mmmmNΩ/kmKg/km
167/1.705.1028401.80243.5
257/2.156.4543551.12769.6
357/2.507.5057600.833294.1
507/3.009.0079300.5786135..5
707/3.6010.80109500.4018195.1
957/4.1612.48144500.3009260.5
12019/2.8514.25194200.2373333.5
15019/3.1515.75233100.1943407.4
18519/3.5017.5284400.1574503.0
21019/3.7518.75322600.1371577.4
24019/4.0020.00362600.1205656.9
30037/3.2022.40468500.09689820.4
40037/3.7025.90611500.072471097
50037/4.1629.12763700.057331387
63061/3.6332.67919400.045771744
80061/4.1036.901159000.035882225