Low Voltage XLPE PVC Insulated Armoured Flexible Electric (YJV/YJV22-0.6/1KV) Power Cable


Application:

This product is suitable for power transmission and distribution line of rated voltage (U0/U) 0.6/1.0KV line.

Technical Parameter:

When the cable is running normally, the Maximum temperature of conductor is 90℃; and is 250 ℃ when the short circuit (Max. last 5s) happens.

The ambient temperature of installation shall not lower than 0 degrees.

Minimum bending radius is 12 D (“D” refers to cable diameter)

  • Complete Cable:
    • One phase conductor, and one neutral conductor are insulated with Extruded Cross-Linked Polyethylene (XLPE) and jacketed with Extruded High-Density Cross-Linked Polyethylene (HDXLPE)
    • Twisted cables form duplex assembly
    • Manufactured and tested in accordance with ANSI/ICEA Standard S-81-570
    • When specified, cable is produced in accordance with UL 854 and listed as a Type USE-2 cable
  • Conductors:
    • Class B compressed aluminum 1350-H19 meeting the requirements of ASTM B231 or B786
  • Insulation & Jacket:
    • Insulation is Extruded Black Cross-Linked Polyethylene (XLPE)
    • Jacket is Extruded High-Density Cross-Linked Polyethylene and meets requirements of ASTM D1248, Type III
    • The phase conductor is black, and the neutral conductor is black identified by three extruded yellow stripes.

Jacketed Aluminum Duplex Conductor Underground Power Cable Features and Benefits:

  • Insulation/Jacket system provide high degree of protection against insulation damage
  • For NEC-complying applications, the maximum conductor operating temp is 90°C in wet or dry locations
  • Also suitable for non-code-complying installations with a temperature of 90°C in wet or dry locations in accordance with ICEA specifications

Jacketed Aluminum Duplex Conductor Underground Power Cable Applications:

  • Intended for use in underground systems operated at 600 volts or less.

Jacketed Aluminum Duplex Conductor Underground Power Cable Options:

  • Aluminum 1350-H16 conductor
  • Copper conductors
  • Other neutral identification methods
  • CDC Combined Duct & Cable
  • Reeless Package
  • PE Insulated/HDPE Jacketed rated 75°C, Type UD-S
  • Type USE-2 per UL 44

Single Core Cable

Nominal cross sectionNominal Thickness of InsulationNominal thickness of SheathApprox. Overall Diameter of CableApproximate weight of cableConductor DC resistanceTest voltageCable Current
In the airBuried in soil
CuALCuALCuALCuAL
mm²mmmmmmKg/kmKg/kmΩ/kmΩ/kmkv/5minAAAA
1*1.50.71.565353≤12.1≤12.13.526263332
1*2.50.71.5668≤7.413.53443
1*40.71.578764≤4.61≤7.413.544355642
1*60.71.5711073≤3.08≤4.613.556457054

Two Cores Cable

Nominal cross sectionNominal Thickness of InsulationNominal thickness of SheathApprox. Overall Diameter of CableApproximate weight of cableConductor DC resistanceTest voltageCable Current
In the airBuried in soil
CuALCuALCuALCuAL
mm²mmmmmmKg/kmKg/kmΩ/kmΩ/kmkv/5minAAAA
2*2.50.71.811.8151118≤7.41≤12.13.526203527
2*40.71.812.7198146≤4.61≤7.413.534274536
2*60.71.813.7250173≤3.08≤4.613.543355746
2*100.71.816.3374245≤1.83≤3.083.560477759

Three Cores Cable

Nominal cross sectionNominal Thickness of InsulationNominal thickness of SheathApprox. Overall Diameter of CableApproximate weight of cableConductor DC resistanceTest voltageCable Current
In the airBuried in soil
CuALCuALCuALCuAL
mm²mmmmmmKg/kmKg/kmΩ/kmΩ/kmkv/5minAAAA
3×1.50.71.510145-≤12.1-3.520-27-
3×1.60.71.511185140≤7.41≤12.13.526203527
3×40.71.512250175≤4.61≤7.413.534274536
3×60.71.513320210≤3.08≤4.613.543355746
3×100.71.515450260≤1.83≤3.083.560477759

Four Cores Cable

Nominal cross sectionNominal Thickness of InsulationNominal thickness of SheathApprox. Overall Diameter of CableApproximate weight of cableConductor DC resistanceTest voltageCable Current
In the airBuried in soil
CuALCuALCuALCuAL
mm²mmmmmmKg/kmKg/kmΩ/kmΩ/kmkv/5minAAAA
4×40.71.513253155≤4.61≤7.413.534274536
4×60.71.514337184≤3.08≤4.613.543355746
4×100.71.516501258≤1.83≤3.083.560477759