SPECIFICATIONS | |
Fuel Type | LPG Vapor or Natural Gas |
Inlet Pressure | -1.5” w.c. (-0.37 kPa) |
Operating Temperature Range | -40ºF to +250ºF (-40ºC to 121ºC) |
Mounting Position | Any |
Diaphragm Material | N/A |
HP/kW Rating | Up to 75 hp (55.9 kW) @ 118 CFM (55.7 L/s) and 2.0” Hg manifold depression |
The idle air fuel mixture is best adjusted only with a engine CO
exhaust analyzer and the mixture should be adjusted to 0.30 to 0.70
percent carbon monoxide.
Alternate Method:
* Adjust idle to 400-500 rpm
* Turn idle air screw out until engine starts to run rough.
* Turn idle air screw in approximately ¼ turn to ½ turn or until
engine smoothes out.