Transmission 40.5kV Manual Vacuum Circuit Breaker Draw Out Type

Brand Name:XG
Certification:ISO CCC
Model Number:ZN23
Minimum Order Quantity:1set
Delivery Time:7-15 DAYS
Payment Terms:L/C, T/T, D/A, D/P, Western Union, MoneyGram
Contact Now

Add to Cart

Verified Supplier
Address: Weibei industrial zone, Lintong district, Shanxi. CHINA
Supplier`s last login times: within 2 hours
Product Details Company Profile
Product Details

1. Transmission 40.5kV Manual Vacuum Circuit Breaker Draw Out Type


"Vacuum circuit breaker" is named after its arc extinguishing medium and the insulating medium of the contact gap after arc extinguishing are both high vacuum; it has the advantages of small size, light weight, suitable for frequent operation, and no need for maintenance of arc extinguishing. The application in the network is more popular. Vacuum circuit breaker is an indoor power distribution device in a 3~10kV, 50Hz three-phase AC system,


2. Parameter of air circuit breaker draw out type

NOItemUnitsTechnical parameters
1Rated voltagekV40.5
2Thunder impulse withstand voltage(peak value)kV185
3lmin industrial frequency withstand voltagekV95
4Rated frequencyHz50
5Rated currentA1250,1600,2000
6Rated short-circuit break currentkA2531.5
7Rated peak value withstand currentkA2531.5
8Rated peak value withstand currentKA6380
9Rated short-circuit duration times4
10Rated short circuit breaking timems
11Rated short circuit closing currentkA80
12Rated operation order0-0.3s-C0-180s-C0
13Time of closing brakems50~85
14Time of breaking brakems40~85
15Rated short-circuit current break and close timesTimes20
16Mechanical life-spanTimes10000
17Rated dropout current of condenser bankA630
18Rated power of energy-storage electric machineW275
19Rated volt of energy-storage motorV25 ± 2
20Storage timeS≤15
21Closing and opening solenoid rated voltageV≈220,110
22Loss of pressure tripping device rated voltageV≈220,110
23Over current tripping device rated currentA5
24Auxiliary switch rated voltage currentADC10


3. Working application
Amplitude: earthquake intensity does not exceed 8 °,
Air relative humidity on average less than 95%, on average less than 90%
An ambient air temperature: to +40 °C, the lower limit of -150°C,
Altitude:. ≤ 1000m (For higher altitudes, the rated insulation board level relative increase)
No risk of fire, explosion, serious pollution, chemical corrosion and severe vibration.

4. Technical drawings


5. Factory


6. Delivery



7. FAQ
1. Send the technical data, better for all useful information; we will make a good recommendation.
If possible please attach one reference picture to avoid any misunderstanding or any links from our website for we get a better understanding.
2. The lead time depend on quantity of order. Some standard type is on stock. Otherwise, it will take 3-15 days.
3. Usually shipped by sea, small order or urgent order we can send you by air.
4. All our activities are accredited to ISO 14001:2015 and IEC standard.

China Transmission 40.5kV Manual Vacuum Circuit Breaker Draw Out Type supplier