1. VS1 -12KV fixed type side type indoor vacuum circuit breaker
630A 1250A
VS1 -12KV fixed type indoor vacuum circuit breaker is rated voltage
12kV, three-phase AC 50Hz/60Hz Indoor high-voltage switchgear
,applied for power stations, substations, and industrial and mining
enterprises to control or protection transmission and distribution
systems , specially for the important high altitude breaking load
and frequent operation place.
Circuit breaker manufacturing accordance with our national standard
GB1984-2003 <AC high voltage circuit breakers>, DL /
T403-2000<3.6 ~ 40.5kV Indoor Vacuum Circuit Breaker ordering
technology>; and the related IEC standards And reliable
interlock function.
Circuit breaker operating mechanism for the spring energy storage
type, can use AC and DC energy storage operations, can also be used
manually.
Circuit breaker can also be equipped with long life permanent
magnetic actuator, mechanical life can reached 60000 times , can be
used for extremely Frequent operation place,
Circuit breaker designed to repackage the structure before and
after, both can be used as a fixed installation unit, Can also be
equipped with the chassis as used in the mounted unit.
2. use of environmental conditions:
1.Ambient temperature: not higher than +40 °C, not less than -15°C
2. Altitude: not exceed 1000m.
3. Relative humidity: daily average of not more than 95%, month
average of not more than 90%.
4. Earthquake intensity: not more than ten.
5. No fire, explosion hazard, serious filthy, chemical corrosion,
as well as places of intense vibration.
3. Mainly technical parameters | |||
NO | Item | Units | parameters |
1 | Rated voltage | KV | 12 |
2 | Rated Frequency | HZ | 50/60 |
3 | Rated Current | A | 2000A |
4 | Rated short-circuit breaking current | KA | 40KA |
5 | Rated short-circuit closing current (peak) | KA | 50 63 80 |
6 | Rated short-circuit duration | S | 4 |
7 | Rated short-circuit breaking current breaking number | nos | 50s |
8 | Rated operating sequence | 0-0.3s-CO-180s-CO | |
9 | Rated lightning impulse withstand voltage | kv | 125 |
10 | 1min power frequency withstand voltage | KV | 65 |
11 | Closing time | ms | ≤ 70 |
12 | opening time | ms | ≤ 50 |
13 | Mechanical life | Times | 20000 |
14 | Rated Storage and operation voltage | V | AC DC 220/110 |
15 | Breaking life | ms | ≤ 80 |
16 | Storage life | s | ≤ 10 |
Adjust the parameters of mechanical properties: | |||
No | Item | Unit | Parameters |
1 | Contact distance | mm | 14±1 |
2 | Contact Over-travel | mm | 3.5±1 |
3 | Closing speed | m/s | 1.0±0.2 |
4 | Opening speed | m/s | 1.3±0.2 |
5 | Contact closing spring time | ms | ≤2 |
6 | Rated contact pressure | N | 40KA (4000±200) |
7 | Three phase closing opening asynchrony | ms | ≤2 |
4. Application
Maximum temperature: +40℃; Minimum temperature:-25℃.
Altitude above sea level: Maximum installation altitude: 2500m.
Humidity: Monthly average humidity 95%; Daily average humidity 90%
.
Ambient air not apparently polluted by corrosive and flammable gas,
vapor etc.
No frequent violent shake.