Home /

Fireproof 10mm2 4 Core 0.7mm PVC Insulated Power Cable Water Resistant

Fireproof 10mm2 4 Core 0.7mm PVC Insulated Power Cable Water Resistant

Brand Name:OEM
Certification:CE, CB
Minimum Order Quantity:Negotiable
Delivery Time:15-20 working days or Negotiation
Payment Terms:T/T, L/C, D/P, West Union, Paypal, Secure Payments
Place of Origin:China
Contact Now

Add to Cart

Verified Supplier
Supplier`s last login times: within 48 hours
Shipping
lt's easy to get a shipping quote! Just click the button below and complete the short form.
Get Shipping Quote
Product Details Company Profile
Product Details

4*10 sq.mm PVC Multi-core cable to IEC 60502-1 Cu-conductor, PVC Insulated and sheathed


0.6/1kV, PVC Insulated Cables according to IEC 60502-1 (unarmoured)


Power cables for energy supply are installed in open air, in underground, indoors, in cable ducts, power stations, residental connections and street lighting as well as in subscriber networks, where mechanical damages are not be expected.


4 Core Electrical Cable​ Quick details

-------------------------------------------------------

– Nominal cross section:4X10mm2

– Overall diameter Ø approx:16.7mm

– Net weight approx: 567 kg/km

– Conductor DC resistant at 20°C:1.83Ω/km


4 Core Electrical Cable​ Dimensional characteristics

-------------------------------------------------------

– Nominal cross-section: 10 mm2

– No of Conductors: single 4 Core

– Insulation thickness: 0.7mm

– sheath thickness nominal value:1.8 mm

– Max overall diameter Ø: 16.7 mm

– Approximate weight:567 kg/km


4 Core Electrical Cable​ Standards

-------------------------------------------------------

International: IEC 60502-1
National:GB/ T 12706.1-2008


4 Core Electrical Cable​ Construction characteristics

-------------------------------------------------------
1. Conductor
– Bare copper conductor, Class 2 to IEC 60228

–​ For smaller sizes, a solid round conductor, Class 1
2. Insulation: XLPE Compound

3. Filler: PP filler
4. Outer Sheath :PVC Compound
5. Sheath colour :Black


-------------------------------------------------------

For prompt quotation / supplies please make sure your inquiries and your orders are
securing the following data :

1 - International or Special Standard. (Alternatively, the precise usage of the cable.)
2 - Rated voltage.
3 - Copper or Aluminium conductors.
4 - Size of each conductor.
5 - Insulation material : XLPE or others.
6 - Number and identification of conductors.
7 - Other requirements.
8 - Packing.
9 - Required delivery time.
10 - Required validity.

4 Core Electrical Cable​ Electrical characteristics

-------------------------------------------------------

–Rated voltage Uo/U (Um): 600 / 1000 V

–Maximum current rating air 30°C:67A

–Maximum current rating buried 20°C: 84A

–Maximum DC resistance, conductor 20°C:1.83Ω / km

–Test voltage: 4000 V

Our production in numbers

200 Sets Of Testing Equipment, 100 Testing Items, 8 workshop

40 wire drawing machines,10 bunching machines, 28 Extruder system, 42 stranding machines,10 Braiding machines

Manufacturing Plant


100,000 m2 Production area

2 Manufacturing plant
1 R&D Center

350 Will-trained employees

Our products at a glance


–​ Medium voltage power cable

–​ 0.6/1 kV Low volate power cable

–​ Copper building wire up to 750 Volts

–​ Ethernet Lan cable cat.5e, cat6, cat.6A cat.7

–​ Control cable

–​ Fibre optical cable

–​ Coxial cable

4 Core Electrical Cable​ Usage characteristics

-------------------------------------------------------

– Maximum operating temperature: 90 °C

– Short circuit temperature: +250°C (short circuit duration max. 5 s)

– during installation up to -20°C

– Temperature range: - 20 to + 90 °C

– Minimum bending radius:15 x cable Ø

Note:

when required for a particular application, other colors are available.

RECOMMENDED ORDERING PARAMETERS



Physical and Electrical Characteristics:



INSTALLATION METHOD DETAILS


A1 – Thermally insolated wall (Single-core)A2 – Thermally insolated wall (multi-core)B1 – Apparent electroduct (Single-core)B2 – Apparent electroduct (multi-core)
B1 – Electroduct in brickwork (Single-core)B1 – Electroduct in brickwork (multi-core)C – On the wall C – On the ceiling
C – Non-perforated trayF – Perforated tray (Single-core)F – Perforated tray (multi-core)F –Suspended (Single-core)
E – Suspended (multi-core)B2 – Construction spaceB2 – Construction spaceB1 – Electroduct (Single-core)
B2 – Electroduct (Multi-core)B2 – Closed raceway embedded in floor (multi-core)B2 – Closed raceway embedded in floor (multi-core)B1 – Ventilated raceway embedded in floor
C – Embedded in the brickworkD – Buried in additional mechanical protection

Cable Drum Data


CABLE DRUMSD1=Flange Diameter(mm)W=Useful Width (mm)D2=Barrel Diameter(mm)
1000700500
1100700550
1200700600
1400750710
1600900900
180011201000
240011501300

WARRANTY

-----------------------------------------------------------------------------------------------------------

For a period commencing on the date shipped the Goods to Buyer and continuing for a period of 12 months thereafter.


Note:

-----------------------------------------------------------------------------------------------------------

  • Photographs are not to scale and do not represent detailed images of the respective products
  • Sale to business customers only
  • Information in this document is subject to change without notice
China Fireproof 10mm2 4 Core 0.7mm PVC Insulated Power Cable Water Resistant supplier

Fireproof 10mm2 4 Core 0.7mm PVC Insulated Power Cable Water Resistant

Inquiry Cart 0