ISO 330 Ω ZTTCE 10.00Mhz PZT Crystals And Resonators

Brand Name:HM
Certification:Rohs,ISO
Model Number:ceramic resonator 10.00Mhz ZTTCE10.00MG50HD0-R0
Minimum Order Quantity:1000
Delivery Time:35 day
Payment Terms:paypal, Western Union, MoneyGram
Contact Now

Add to Cart

Verified Supplier
Location: Wuxi Jiangsu China
Address: Dongxing Road, Golden Bay Industrial Zone, Dongjiang Town, Binhu District, Wuxi City, Jiangsu Province Hansejohn Electronics
Supplier`s last login times: within 38 hours
Product Details Company Profile
Product Details

NO.ComponentsMaterials
1

Outer Electrodes

Top and Bottom Electrodes

Ag+Ni(under plating)+Sn(over plating)

Side Electrodes

Ni+Cu+Ag(under plating)+Sn(over plating)

2Ceramic Box

Insulation Box

3CoverDielectric Material
4GlueEpoxy Resin
5Conductive Adhesive

Ag+Epoxy Resin

6Base

Dielectric Material

7Ceramic ElementPiezoelectric Ceramics (PZT)

4.ELECTRICAL SPECIFICATIONS

4.1 RATING

ItemsRequirement
Withstanding Voltage (V)50 (DC,1min)
Insulation Resistance Ri,(MΩ)min.500 (10V,1min)
Operating temperature-25℃~+85℃
Storage temperature-55℃~+85℃
Rating Voltage UR(V)6V DC
15V p-p

4.2 ELECTRICAL SPECIFICATIONS

ItemsRequirement
Oscillation Frequency Fosc (MHz)10.000
Frequency Accuracy (%)±0.5
Resonant Impedance Ro (Ω)max.40

Temperature Coefficient of Oscillation

Frequency (%) max.

±0.3

(Oscillation Frequency drift,-25℃~+85℃)

Oscillation Frequency

Aging Rate(10years) (%) max

±0.2 (From initial value)

*Components shall be left in a chamber of +85±2℃ for 1000 hours, then measured after leaving in natural condition for 1 hour.

5.TEST

5.1 Test Conditions

Parts shall be tested under the condition ( Temp.:20±15℃,Humidity :65±20%

R.H.) unless the standard condition(Temp.:25±3℃,Humidity :65±10% R.H.)

is regulated to measure.

NoItemCondition of Test

Performance

Requirements

6.1HumidityKeep the resonator at 40℃±2℃ and 90%-95% RH for 96h. Then Release the resonator into the room Condition for 1h prior to the Measurement.It shall fulfill the specifications in Table 1.
6.2

High

Temperature

Exposure

Subject the resonator to 85±2℃ for 96h, then release the resonator into the room conditions for 1h prior to the measurement.It shall fulfill the specifications in Table 1.
6.3

Low

Temperature Exposure

Subject the resonator to -55±2℃ for 96h, then release the resonator into the room conditions for 1h prior to the measurement.It shall fulfill the specifications in Table 1.
6.4

Temperature

Cycling

After temperature cycling of blow table was performed 5 times, resonator shall be measured after being placed in natural conditions for 1h.It shall fulfill the specifications in Table 1.
TemperatureTime
–25±3℃30±3 min
85±3℃30±3 min
6.5VibrationSubject the resonator to vibration for 2h each in x,y and z axis With the amplitude of 1.5mm, the frequency shall be varied uniformly between the limits of 10 Hz—55Hz.It shall fulfill the specifications in Table 1.
6.6

Mechanical

Shock

Drop the resonator randomly onto a wooden floor from the height of 100cm 3 times.It shall fulfill the specifications in Table 1.

6.7


Soldering TestPassed through the re-flow oven under the following condition and left at room temperature for 1h before measurement.It shall fulfill the specifications in Table 1.

Table 1





China ISO 330 Ω ZTTCE 10.00Mhz PZT Crystals And Resonators supplier

ISO 330 Ω ZTTCE 10.00Mhz PZT Crystals And Resonators

Inquiry Cart 0