Home /Rare Earth & Products /

Thermocouple Type K Extension Cable For Temperature Compensation

Thermocouple Type K Extension Cable For Temperature Compensation

Brand Name:DLX
Certification:CE,ROHS
Model Number:Type k Thermocouple extension wire
Minimum Order Quantity:5
Delivery Time:5-21 days
Payment Terms:L/C, T/T, Western Union, MoneyGram
Contact Now

Add to Cart

Verified Supplier
Location: Changzhou Jiangsu China
Address: NO.32 West Taihu Road, Xinbei District, Changzhou, Jiangsu
Supplier`s last login times: within 1 hours
Shipping
lt's easy to get a shipping quote! Just click the button below and complete the short form.
Get Shipping Quote
Product Details Company Profile
Product Details

Thermocouple Type K Extension Cable for Temperature Compensation


The compensation wire models are divided into SC, KC, KX, EX, JX, TX according to the product variety.

Among them: a) The first letter of the model corresponds to the graduation number of the thermocouple;

b) The letter "X" represents the extended compensation wire (type)

c) The letter "C" represents the compensation type compensation wire (type)

Note: SC type compensation wires can be equipped with R-type indexing thermocouples.

  • Thermocouple Extension Wire

Type K Extension Cable 0.5*2 red black pvc insulation with pvc sheath. The conduct is thermocouple type K material which is nickel-chrome with nickel-siliconor nickel-aluminum. The construction is similar to pair instrumentation cable but the conductor material is different. Thermocouples are used in processes to sense temperature and is connected to the pyrometers for indication and control. The thermocouple and pyrometer are electrically conducted by thermocouple extension cables / thermocouple compensating cables. The conductors used for these thermocouple cables are required to have similar thermo-electric (emf) properties as that of the thermocouple used for sensing the temperature.

Basically, Fine Wire Thermocouple grade wires are used to make sensing points of thermocouples. However, a Thermocouple Extension Wire is only used to extend a thermocouple signal back from the probe to the instrument reading it. A thermocouple Extension Cable is used in lower ambient temperatures. It may pass a signal representing a higher temperature than it received from the probe. However, Type K Thermocouple Extension Wire may not be physically exposed to that high temperature. A Stranded Thermocouple Wire can be used as an extension wire but an extension wire cannot be used in a Flexible Thermocouple Wire as a sensing point. The usable length of these wires differs based on numerous factors.



  • Thermocouple Wire
CodeWires component of the thermocouple
+Positive leg-Negative leg
NNi-cr-si (NP)Ni-si-magnesium (NN)
KNi-Cr (KP)Ni-Al(Si) (KN)
ENi-Cr (EP)Cu-Ni<constantan> (EN)
JIron (JP)Cu-Ni<constantan> (JN)
TCopper (TP)Cu-Ni<constantan> (TN)


  • ​Standards
ASTMANSIIECDINBSNFJISGOST
(American Society for Testing and Materials) E 230(American National Standard Institute) MC 96.1(European Standard by the International Electrotechnical Commission 584)-1/2/3(Deutsche Industrie Normen) EN 60584 -1/2(British Standards) 4937.1041, EN 60584 - 1/2(Norme Française) EN 60584 -1/2 - NFC 42323 - NFC 42324(Japanese Industrial Standards) C 1602 - C 1610(Unification of the Russian Specifications) 3044

Detailed Parameter of thermocouple wire

Working Temperature Range


Diameter/mmLong time Working temperature /ºCShort period Working temperature /ºC
0.3700800
0.5800900
0.8,1.09001000
1.2,1.610001100
2.0,2.511001200
3.212001300

Thermocouple No. indexingCompensation wire typeUsag ClassificationMeasuring junction temperature / ℃standard EMF value/μVPrecision gradeGeneral grade
Tolerance μVThermal EMF range μVTolerance μVThermal EMF range μV
SorRSC or RCG100646±30616~676±60586~706
H100646--±60586~706
2001 1441--1.381~1 501
KKX,KCAG-25-968±40-924~-1 012±80-880~-1 056
or KCB1004 0964 052~4 1404 008~4 184
H-25-968±40-924~-1 012±88-880~-1 056
1004 0964 052~4 1404 008~4 184
2008 1388 094~8 1828 050~8 226
NNX or NCG-25-646±43-603~-689±86-560~-732
1002 7742 731~2 8172 688~2 860
H-25-646±43-603~-690±86-560~-732
1002 7742 731~2 8172 688~2 860
2005 9135 870~5 9565 827~5 999
EEXG-25-1 432±81-1 351~-1 513±138-1 294~-1 570
1006 3196 238~ 64006 181~6 457
H-25-1 432±81-1 351~- 1513±138-1 294~-1 570
1006 3196 238~6 4006 181~6 457
20013 42113 340~13 50213 283~13 559
JJXG-25-1 239±62-1 177~-1 301±123-1 116~-1 362
1005 2695 207~5 3315 146~5 392
H-25-1 239±62- 177~-1 301±123-1 116~-1 362
1005 2695 207~5 3315 146~5 392
20010 77910 717~10 84110 656~10 902
TTXG-25-940±30-910~-970±60-850~-1 000
1004 2794 249~4 3094 189~4 339
H-25-940±48-892~-988±90-850~-1 030
1004 2794231~4 3274 189~4 369
200



Size range



Wire: 0.12 to 8.0 mm.


  • Type N Accuracy (whichever is greater):
  • Maximum continuous operating temperature: up to 2,300F (1,260C)

  • Short term use: 2,336F (1,280C)

  • Thermocouple grade wire, -454 to 2300F (-270 to 1,260C)

  • Extension wire, 32 to 392F (0 to 200C)

China Thermocouple Type K Extension Cable For Temperature Compensation supplier

Thermocouple Type K Extension Cable For Temperature Compensation

Inquiry Cart 0