Repair Thermostat Core Kit 719750 Air Compressor Valves

Brand Name:QINGDAO FUTAI
Certification:ISO 9001:2015
Model Number:7.1975.0 7.2019.0
Minimum Order Quantity:1
Packaging Details:Carton, Wooden cases, Plastic bag, etc, make the package as your requirement.
Place of Origin:CHINA
Contact Now

Add to Cart

Active Member
Location: Qingdao Shandong China
Address: No.21 Tongshun Road, Chengyang High-tech Zone, Qingdao, Shandong, China
Supplier`s last login times: within 27 hours
Product Details Company Profile
Product Details

Screw Air Compressor Valves Repair Thermostat Core Kit 719750


The function of the Thermostatic Valve is the regulation of the oil flow in oil-injected screw compressors. Fastest possible regulation of the oil temperature to the optimum operating temperature to ensure full performance of the oil and to avoid premature condensation fall-out.


BrandProduct NamePart Number
Atlas CopcoThermostat 70°-85°C1202586901
Atlas CopcoThermostat 60°C1202586902
Atlas CopcoThermostat 55°C1202586903
Atlas CopcoThermostat Core1613688303
Ingersoll RandThermostat22186720
Ingersoll RandThermostatic Element39207402
Ingersoll RandThermostatic Element39437645
Ingersoll RandThermostatic Element39442439
KaeserMaintenance Kit Thermostatic Valve 70°C400952.00010
KaeserMaintenance Kit Thermostatic Valve 75°C400952.00020
KaeserMaintenance Kit Thermostatic Valve 80°C400980.00030
KaeserMaintenance Kit Thermostatic Valve 85°C400980.00040
KaeserMaintenance Kit Thermostatic Valve 65°C401811.0
KaeserMaintenance Kit Thermostatic Valve 75°C401811.00020
KaeserMaintenance Kit Thermostatic Valve401811.00030

Product advantages

  • Direct Replace Kaeser & Product Compatibility 100%.
  • High Quality Raw Materials,Cost- Effective,Rrduce maintenance Cost.
  • Ensure To Meet Original Manufacturing Standard.

Why thermostatic valve is required?


The valve is needed for when the compressor is still cold (after stop) or when it is running in very cold conditions (winter).

When the compressor oil is cold, the valve is bypasses the oil cooler so no oil flows through the cooler. This is done to heat up the oil as soon as possible to remove water condensate.

Low temperatures are the number 1 enemy of screw compressors. The compressor needs to heat up quickly to remove any water condensate as quickly as possible.

If you remove it, one of two things will happen: all oil will flow through the oil cooler. Or no oil flows through the oil cooler at all. Probably the second thing will happen as it’s the path of least resistance.


China Repair Thermostat Core Kit 719750 Air Compressor Valves supplier

Repair Thermostat Core Kit 719750 Air Compressor Valves

Inquiry Cart 0