02250049634 Alternative Sullair Air Compressor Blowdown Valve

Brand Name:QINGDAO FUTAI
Certification:ISO 9001:2015
Model Number:02250049-634
Place of Origin:CHINA
Packaging Details:Carton, Wooden cases, Plastic bag, etc, make the package as your requirement.
Part Number:02250049-634
Contact Now

Add to Cart

Active Member
Location: Qingdao Shandong China
Address: No.21 Tongshun Road, Chengyang High-tech Zone, Qingdao, Shandong, China
Supplier`s last login times: within 27 hours
Product Details Company Profile
Product Details

Blowdown Valve 02250049634 Sullair Air Compressor Valves


The normally closed blow down valve is commonly used to blow down the air/oil separator tank of a rotary screw compressor. The valve is attached to the tank so the tank pressure keeps the valve closed. To “blow down” the tank the valve is piloted open. The piston is designed so that the pilot pressure is less than the tank pressure. The Blow Down valve is a piloted normally open or normally closed valve..


The valve can have an orifice on the exit so that the flow is controlled. The valve is fully pneumatic so that no spring is present. The valve is piloted to act and the system operates to return the valve.


Sullair Spare Parts
250024-783Repair Kit Valve
250025-621Thermal Valve Rep Kit
250025-655Blowdown Valve
250031-771Repair Kit for blowdown valve
250038-673Repair Kit for Solenoid Valve
250039-909Termperature Transducer
406929Valve, Diff Press Reg 1/4"NPT
02250049-634Blowdown Valve 1/4
02250050-612Check MPV Kit
02250050-614Intake Contro Valve Kit
02250055-940Solenoid Valve
02250058-087Temperature Sensor
02250083-661Inlet Valve Kit
02250110-988KIT,RPR 1-5/8"SAE MPV
02250122-079KIt, BLWDN VLV Rebuild DS13
02250129-175Drain kit

Fault solution - Compressor oil comes out of blowdown valve


  1. With compressor off, check oil level in compressor both visually and by indicator switch to verify oil level, excessive oil level may cause this.
  2. Check plumbing of blow down valve the “P” marking on valve should be connected to inlet valve plate and “I” marking should go to ¼ inch tube going to fresh air port of compressor
  3. Check blowdown valve for functionality and shifting to insure not stuck or sticking
  4. Check coalescer scavenge line sight glass which is located on top of compressor next to coalescer element, when working properly one should see slugs of oil in sight glass, if no oil is visible scavenge line circuit is not working

Main products:

  • Valve Assembly:Air Intake valve, Thermostat Valve, Solenoid Valve, Mminimum Pressure Valve, Blow Off Valve, Drain Valve and so on.
  • Rubber Parts: Hose, Coupling, Elbow, Anti-Vibration Pad, Belt and so on.
  • Sensor: Temperature Sensor, Pressure Sensor, Oil Level Sensor.
  • Other Parts: Gear Set, Oil Seal, Shaft Sleeve, Spring, Controller, Oils and so on.


China 02250049634 Alternative Sullair Air Compressor Blowdown Valve supplier

02250049634 Alternative Sullair Air Compressor Blowdown Valve

Inquiry Cart 0