Quick Measurement Portable ROHS Finger Oximeter With Pulse

Brand Name:IMDK
Certification:CE FDA ROHS ISO
Model Number:H8
Minimum Order Quantity:50pcs
Delivery Time:4-9 work days
Payment Terms:L/C, D/A, D/P, T/T, Western Union, MoneyGram
Contact Now

Add to Cart

Verified Supplier
Address: Huichuang workshop 306, 307 building B, no.8 factory, stone street Co,.ltd, gushu community, xixiang street
Supplier`s last login times: within 34 hours
Product Details Company Profile
Product Details

Quick Measurement Portable ROHS Finger Oximeter With Pulse


Suitable Comfortable Quick Measurement Fingertip Pulse Oximeter Portable


Products principle:

Oxygenated blood absorbs light preferentially at 940nm (near infra-red light),

whereas deoxygenated blood absorbs light preferentially at 660nm ( red light).

A pulse oximeter works by passing a beam of red and infra-red light through a

pulsating capillary bed and then measures the amount of the red and infra-red

light emerging from the tissues via a sensor. The relative a bsorption of light by

oxyhemoglobin( HbO) and deoxyhemoglobin is then processed according to the

Beer-Lambert's law and the oxygen saturation level( SpO2) determined.


Product performance parameters

Oximeter arrangement70% ~ 99%
Pulse rate measurement range:30BPM ~ 240BPM
Screen displayColors TFT display
defined Pulse rate measurement accuracy:±1BPM or ± 1% of the measured value
Screen Resolution:128*64
Power consumption:less than 30mA
Humidity:15%~80%
Power supply

2 * 1.5V
(2 AAA alkaline, the product does not contain batteries)

After-sale Service:Online technical support
Packing details:oximeter*1, lanyard*1, Warranty Card*1

Products features:
SpO2 value displayPulse rate value display, bar graph display
Pulse waveform display
The display mode can be changed
Screen brightness can be changed
Low-voltage indication: low-voltage indicator appears before working abnormally which is
due to low-voltage,Automatically power off function: when the device is under the state of
measuring interface . it will automatically power off within 5 seconds if the finger falls out of probe
Display format can be saved after power off

Resistant to ambient light interference
Suitable for special environments such as dark room strong light, automatic brightness
adjustment system allow users to view the measurement results more clearly

Operation Instructions:
Install two AAA batteries into battery cassette before covering its cover.
Plug one finger into rubber hole of the Oximeter

(it is best to plug the finger thoroughly) before releasing the clamp with the nail upwards.
Press button on the front panel;
Donot tremble your finger when the Oximeter is working.

Your body is not recommended on moving status.
Press the button on the front panel, if we want change display direction;
Read relevant datum from display screen.
If there is no signal input, oximeter can shut off automatically;
Please replace new batteries when OLED indicates the batteries are in low power.


FAQ:

I. Can I have a sample?
Yes, of course, we would like to have long term cooperate with you and have business

with you, about the sample, we also give you good price and shipment also need to be

paid by you.

II. How do I pay?

Before you buy, you can tell me more details of you requirement, you can also send me

information, I could place the order for you. Pay by Credit card, TT payment, western


III.How do you ship the goods and how long does it take to arrive?
We usually ship by DHL, UPS, FedEx or TNT. It usually takes 3-5 days to arrive.
Airline and sea shipping also optional.









China Quick Measurement Portable ROHS Finger Oximeter With Pulse supplier

Quick Measurement Portable ROHS Finger Oximeter With Pulse

Inquiry Cart 0