Dual MOS parallel active output, lower internal resistance, larger
current, strong power interface, clear and simple, powerful,
one-button emergency stop function (STOP button), with reverse
connection protection, reverse connection, no burning, power-off
memory. Increase Sleep mode, after enabling, no operation within 5
minutes, automatically turn off the display, wake up any button!
You can set different OP, CL, LOP parameters, these parameters are
independent of each other, save the setting parameters
automatically power-down save and other functions, Almost all the
needs!
1.Product manual Working voltage: DC5V-DC30V (wide voltage anti-connection
protection) Trigger signal source: high-level trigger DC 3.0V—24V signal ground
and system ground to improve the system's anti-interference ability
can also short-circuit the ground Output capacity: DC DC 5V--36V, continuous current 15A at normal
temperature, power 400W! Under the condition of auxiliary heat
dissipation, the maximum current can reach 30A Product size: 64mm*35mm*19.3mm Mounting hole: diameter 3mm Working temperature: -40 ° C ~ 85 ° C
2.Operating mode P1 mode: After the signal is triggered, the MOS transistor turns on
the OP time and then turns off; in the OP time, the following
operation P1.1: The signal is triggered again. P1.2: Signal triggers re-timed again P1.3: The signal triggers reset again, the MOS tube is
disconnected, and the timing is stopped. P-2: Give the trigger signal, after the MOS transistor is
disconnected from the CL time, the MOS transistor turns on the OP
time. After the timing is completed, the MOS transistor is
disconnected. P3.1: Give the trigger signal, after the MOS transistor turns on
the OP time, the MOS tube turns off the CL time, then loops the
above action, the signal is given again in the loop, the MOS tube
is disconnected, the timing is stopped; the number of cycles (LOP)
can be set. P3.2: No need to trigger signal after power-on, MOS tube turns on
OP time, MOS tube disconnects CL time, loops the above action; loop
number (LOP) can be set P-4: Signal hold function If there is a trigger signal, the timing
is cleared, the MOS transistor remains on; when the signal
disappears, the MOS transistor is disconnected after timing the OP;
during the timing, there is a signal and the timing is cleared.
3.Relay enable mode ON : MOS tube is allowed to conduct during OP conduction time OFF : MOS tube is disabled, always off Short press the STOP button on the main interface to switch between
ON and OFF. The current state will flash, then return to the main
interface. This function is the emergency stop function. One button
is used to open and close the MOS tube.
4.Sleep mode (long press the stop button to view the current mode) C-P sleep mode: within five minutes, without any operation, the
digital tube automatically turns off the display, the program runs
normally. O-d normal mode: the digital tube is always on display Press and hold the STOP button for 2 seconds and then release to
switch the C-P and O-d states. The current state will flash and
then return to the main interface.
5.Timing range How to choose the timing range 1).After setting the parameter value in the mode selection
interface, press the STOP button to select the timing range. XXX. Decimal point is in one place, timing range: 1 second to 999
seconds XX.X decimal point in ten, timing range: 0.1 seconds to 99.9
seconds X.X.X. The decimal point is fully illuminated, the timing range is
from 1 minute to 999 minutes. 2).For example, if you want to set the OP to 3.2 seconds, move the
decimal point to ten digits, and the digital tube displays 03.2. Parameter description: OP on time, CL off time, LOP cycle number
1-999 times, "---" stands for infinite loop. These parameters are independent of each other, but each mode
shares these parameters. For example, when the on-time OP is set to
5 seconds in P1.1, the user wants to switch to the P1.2 mode, then
when entering the P1.2 setting corresponding parameters, the OP
also It will be 5 seconds. Displaying 000 on the main interface and pressing the SET button
will display OPL, LOP and corresponding time XXX If only OP in the mode, such as mode P1.1, P1.2, P1.3 time, then
short press SET button will only display OP and corresponding time. If the mode has OP, CL, LOP such as mode P3.1, P3.2 short press SET
button will display OP and corresponding time, CL and corresponding
time, LOP and corresponding times. After setting the mode, it is very convenient to easily check the
parameters set in the current mode by pressing the SET button on
the main interface.
6.How to set parameters 1) First determine the working mode of the MOS tube According to the working mode of the MOS tube, in the main
interface (when the module is powered on, it will flash the current
working mode (default P1.1 mode), then enter the main interface
"press and hold the SET button for 2 seconds and then release" to
enter the mode. Select the interface, press the UP, DOWN button to
select the mode to be set P1.1~P-4 2) After selecting the mode to be set (for example, P3.2), press
the SET button to set the corresponding parameter. At this time,
the parameter to be set will flash OP ON time, CL OFF time, LOP
cycle number “---” Represents an infinite loop, adjusts the
parameter value through UP and DOWN, supports long press (rapid
increase or decrease) and short press (increase or decrease 1
unit); after setting the parameter value, select the decimal point
position by short pressing the STOP button. , select the timing
range (corresponding time 0.1 seconds ~ 999 minutes); short press
the SET button to set the next parameter of the current mode, the
process is the same as above. 3) After setting the parameters of the selected mode, press and
hold the SET button for 2 seconds to release, the currently set
mode will flash, then return to the main interface and set the
parameters successfully. 4) Main interface: “000” (no decimal point) is displayed when the
MOS tube is not working, and the MOS tube has a decimal point in
the working state. 5) Mode selection interface: long press SET button to enter, after
setting is completed, long press SET button to exit, return to the
main interface Note: The module is an active live output, and the voltage at the output
(load) is equal to the input voltage DC
7.Package Included: 1*DDC-432 DC5-30V 4 button 3-digit digital tube Dual MOS Delay
control board +Case |