Home /Power Cables /

Industrial PVC Insulated BV Flexible Electric Wire Cable

Industrial PVC Insulated BV Flexible Electric Wire Cable

Brand Name:FZTL/OEM
Certification:ISO9001
Model Number:BV/BVR/BVVB
Delivery Time:10-35days
Payment Terms:D/P, L/C, T/T
Place of Origin:China
Contact Now

Add to Cart

Active Member
Location: Fuzhou Fujian China
Address: C2-520,Cangshan Wanda Plaza, 216 Pushang Ave.,Cangshan Disctrict Fuzhou, Fujian , P.R. China.
Supplier`s last login times: within 47 hours
Shipping
lt's easy to get a shipping quote! Just click the button below and complete the short form.
Get Shipping Quote
Product Details Company Profile
Product Details

PVC Insulated BV , Flexible Electrical Wire Cable, Building Wire Power Cable Industrial Electric Wire And Cable

Product Description:

PVC insulated wire is suitable for AC rated voltage 450/750V and below the fixed installation of power plant. In normal use, the maximum conductor temperature of 70 ℃ temperature of not less than 0 ℃.

Industrial PVC Insulated BV Flexible Electric Wire CableIndustrial PVC Insulated BV Flexible Electric Wire Cable

Detailed Images:

The PVC insulated wire we produce are BV, BLV, BVR, BVVB, BLVVB and other customization types required by customers. The following are some specifications, sizes and technical parameters of our products.

BV 300/500V

Nominal Section (mm2)

Number and Diameter of Wire Core (mm)

Max Outside Diameter (mm2)

Reference Weight (kg/km)

Conductor Resistance at 20℃ (Ω/km)

0.5

0.75

1/0.80

1/0.97

2.4

2.6

8.5

11.1

36.0

24.5

1.0

1/1.13

2.8

13.9

18.1

BV BLV(BV-105) 450/750V

Nominal Section (mm2)

Number and Diameter of Wire Core (mm)

Max Outside Diameter (mm2)

Reference Weight (kg/km)

Conductor Resistance at 20℃ (Ω/km)

Copper

Aluminum

Copper

Aluminum

1.5

1/1.38

3.3

20.3

12.1

2.5

1/1.78

3.9

31.6

17

7.41

11.8

4

1/2.55

4.4

47.1

22

4.61

7.39

6

7/0.85

4.8

50.3

29

3.08

4.91

10

16

7/1.35

7/1.70

7.0

8.0

119

179

62

78

1.83

1.15

3.08

1.91

25

35

27/2.04

27/2.52

10.0

11.5

281

381

118

156

0.727

0.524

1.20

0.868

50

70

19/1.78

19/2.14

13.0

15.0

521

734

215

282

0.387

0.268

0.641

0.443

95

120

19/2.52

37/2.03

17.5

19.0

962

1180

385

431

0.193

0.153

0.320

0.253

150

185

37/2.25

37/2.52

21.0

23.5

1470

1810

539

666

0.124

0.0991

0.206

0.164

240

300

400

61/2.25

61/2.52

61/2.85

26.5

29.5

33.0

2350

2930

3870

857

1070

1390

0.0754

0.0601

0.0470

0.125

0.100

0.0778

BVVB BLVVB 300/500V

Nominal Section (mm2)

Number and Diameter of Wire Core (mm)

Max Outside Diameter (mm2)

Reference Weight (kg/km)

Conductor Resistance at 20℃ (Ω/km)

Copper

Aluminum

Copper

Aluminum

Copper

Aluminum

2*0.75

2*1.0

2*1/0.97 2*1/1.13

1.6*7.0

4.8*7.4

43.7
51.0

24.5

18.1

2*1.5

2*2.5

2*1/1.38 2*1/1.78

5.4*8.4

6.2*9.8

6.2*9.8

65.9
95.7

12.1

64.9

7.41

11.8

2*4

2*6

2*7/0.85 2*7/1.04

7.2*11.5

8.0*13.0

6.8*11.0 7.4*12.0

146.0 200.0

80.7

104

4.61

3.08

7.39

4.91

2*10

3*0.75

2*7/1.35 3*1/1.38

9.6*16.0

4.6*9.4

9.6*16.0

323.0 62.6

177

1.83

24.50

3.08

3*1.0

3*1.5

3*1/1.13 3*1/1.38

4.8*9.8

5.4*11.5

74.3
95.6

18.10

12.10

3*2.5

3*4

3*1/1.78 3*7/0.85

6.2*13.5

7.4*16.5

6.2*13.5 7.0*15.0

140

220

93.9

123

7.41

7.41

11.8

7.39

3*6

3*10

3*7/1.04 3*7/1.35

8.0*18.0

9.6*22.5

7.4*17.0 9.6*22.5

295

485

153

261

4.61

1.83

4.91

3.08

BVR 450/750V

Nominal Section (mm2)

Number and Diameter of Wire Core (mm)

Max Outside Diameter (mm2)

Reference Weight (kg/km)

Conductor Resistance at 20℃ (Ω/km)

2.5

4

19/0.41

19/0.52

4.2

4.8

34.7

51.4

7.41

4.61

6

10

16

19/0.64

49/0.52

49/0.64

5.6

7.6

8.8

73.6

129

186

3.08

1.83

1.15

25

35

98/0.58

133/0.58

11.0

12.5

306

403

0.727

0.524

50

70

133/0.68

189/0.68

14.5

16.5

553

764

0.387

0.268

Technical Performance:

1. The finished insulated wire and cable can withstand the AC voltage test in the following table after being placed in room temperature water at 20±for at least 1 hour.

2. The wire has good performance in electrical insulation properties, mechanical properties, mechanical properties and non flammable performance, reliable quality, convenient and durable.

3. The insulation or sheath surface of the finished wire shall have the name of the manufacturer, the type and the continuous mark of the voltage.

Test Name
Test Items
Test Value
Rated voltage of wire
300/500V
450/750V
Test of Insulation Wire Core Voltage
Test Voltage according to the insulation thickness
0.6 mm and below
1500
over 0.6 mm
2000
Voltage applied time not less than
5
Finished Wire Voltage Test
Test voltage
2000
Voltage applied time not less than
5

Packaging And Shipping:

Industrial PVC Insulated BV Flexible Electric Wire Cable

Packaging Details:

Packaging can be customized as required

Port: Fuzhou

Shipping:Support Sea Freight/Air Freight

FAQ


Q: What payments can be accepted?
A: T/T in advance, D/P at sight, L/C at sight, Paypal are available.


Q: Do you accept small order?
A: Yes, sample order is available.


Q: How to ship the cargos?
A: We usually ship by Airline, courier, and by sea.


Q: What's your warranty policy?
A: Our warranty period is 12months. Usually, all our products will be tested 100% one by one before delivery.


Q: Are OEM & ODM available?
A: Yes, both are available.


Q: Can we have our logo to be printed on the units or package?
A: For bulk order, we can print logo, customize package as your demands.


Q: Can we have one sample order or small order to try?
A: Yes, welcome to order small quantity for test at first.


Q: How could I get samples?
A: We can provide samples to you via your courier freight collect account.

China Industrial PVC Insulated BV Flexible Electric Wire Cable supplier

Industrial PVC Insulated BV Flexible Electric Wire Cable