Add to Cart
eliminate Pseudomonas aeruginosa Large Room Burn Department Air
Purifier
Medical air purifiers are professionally used in hospital operating
rooms, preparation rooms, ICU/CCU wards, supply sterile rooms, burn
wards, infant rooms, premature infants and delivery rooms,
postoperative recovery rooms, laboratories; negative pressure
wards, fever clinics, Infusion rooms, hospital clean corridors,
etc., and any other places that need to remove harmful aerosols in
the room and maintain a certain level of cleanliness.
Competitive Advantage:
· Medical grade HEPA filtration combined with UVC lights
· Removes 100% of white staphylococcus, Aspergillus Niger
· Removes 100% of particles PM0.5
· Large CADR up to 854.8 m3/h (502 CFM)
· Applicable room volume 100 m3 / 3531 ft3 at 10 ACH
· Low Noise max 60 dB with low operating Power max 124W
· 30850μw/cm2 Ultraviolet radiation intensity (at 1cm) with zero
leakage
· Human-machine coexistence, No harm and safety to human health
· Easy to move and more effective comparing to Laminar flow or HVAC
system’s HEPA
Functional characteristics:
1.95% removal of dust from air
2.99% high efficiency sterilization
3. remove the bad smell from the air
4. high air volume and large capacity product design to ensure the
use of the environment to achieve a considerable number of air
exchange times, improve air quality
5. large amounts of air vitamins - light negative ions
6. indoor cleanliness monitoring - real-time monitoring and control
of indoor air cleanliness through dirt sensing probe
7. temperature and humidity monitoring-through temperature and
humidity sensor, real-time display of indoor air temperature and
humidity
Adjust indoor humidity 8. optional humidifier
Specifications
Technical parameters of MKJ4000-S1 | |
CADR | 854.8m3/h |
Klebsiella pneumoniae sterilization rate | 100% |
Aspergillus Niger sterilization rate | 100% |
Sterilization rate of Staphylococcus albus | 100% |
Natural bacteria death rate | 97.24% |
H3N2 influenza virus killing rate | 99.99% |
Purification rate of PM0.5 for one pass | 100% (on-site inspection) |
UV leakage intensity (at 30cm around the device) | 0μw/cm2 |
Ozone concentration (5cm from the air outlet) | 0.023mg/m3 |
Air dust mite allergen removal rate | 95.23% |
Ultraviolet radiation intensity (at 1cm) | 30850μw/cm2 |
Dimensions (L×W×H) | 520×380×1090mm |
Input power | Max 124W, 3 levels |
Noise | Max 60dB (A), 3 levels |
Product N. W | 50kg |
Product G. W | 55kg |
Voltage and Frequency | 220V/50Hz |
Applications
Main applications | Respiratory unit, ICU, Emergency unit, Transplantation unit, CT room, Fever clinic unit, Blood wards, Burn wards, Neonatal rooms |
Environment Class I | Laminar flow operation room/ward |
Environment Class II | ICU/Hematological/Burn/Bone Marrow Transplant/Obstetric and Gynecologic/Catheter/Neonatal/Organ Transplant room/ward |
Environment Class III | General/Pediatric/Rooming-in/Gynecologic examination/Treatment/Injection/Dressing/Blood Transfusion/Hemodialysis center/Emergency/Laboratory/Infectious Diseases room/ward |
Public places | The bank, Kindergarten, Movie theaters, fitness halls, clubs, massage rooms, bars, cafes etc |
Home care | Care home such as Asthma, Rhinitis, Dust mites, and Pollen allergies populations/ People with weakened immunity such as major postoperative, hemopathy, Chemoradiotherapy patient/ People suffering from respiratory diseases (Asthma, COPD)/ People with allergies (Pollen allergy, allergic rhinitis, allergic dermatitis)/ Gestational woman, children, the aged etc |
Description
Ekeair ® Mobile air sterilization station
High-efficiency Particulate Air Filter (HEPA) is one of the most
popular technologies used in air purification. Standard HEPA filter
can absorb 99.7% size of 0.3 microns of suspended particulates (0.3
microns is the most difficult to filter the size), but its wind
resistance is relatively large, generally rarely used in air
purifiers, the actual air purifier manufacturers claim that HEPA is
not really HEPA its filtration efficiency is slightly lower than
HEPA, wind resistance is relatively low. Both the real HEPA and the
advertised HEPA make the ining air fresher and cleaner. The filter
absorbs chemical fumes, bacteria, dust particles, and pollen, which
are filtered by an air purifier and do not contain these pollutants
in the air.
A Hospital-acquired infection (HAI), also known as a nosocomial
infection between healthcare personnel and patients in the
hospitals. RTI is of highest mortality rate among infections of
operation, hemodialysis and UTI. Reducing the risks of infection
become more and more important either to improve air quality
environment or to save the cost for the hospitals. Ekeair mobile
air sterilization not only realizes human-machines coexistence, but
also captures 99.99% of bioaerosols as small as 0.3 microns. With
medical-grade HEPA filtration, molecular sieve, unique UVC
high-energy particles of photoion α-pure clean control system, it
also inactivate microorganisms such as bacteria, fungi, virus.
Different from most air purifiers on the market, Ekeair mobile air
sterilization station accomplishes 100% eliminates Staphylococcus
albus, Klebsiella pneumoniae(bacteria), Aspergillus Niger (Fungi),
99.99% eliminates H3N2 influ virus etc. Superior performance of air
blower allows large airflow rate 1000 m3/h but with low noise Max
60 dB. The airflow rate is a significant index which indicates an
air sterilizer’s air supply capacity. At the same time, Ekeair air
sterilization can reach CADR 854.8 m3/h, which is suitable for 16
m2 room at 20 ACH.
FAQ
Q: Are you a manufacturer or trading company?
A: Manufacturer.
Q: Where is the production base?
A: Tongxiang City of Zhejiang Province. Marketing center located in
Xuhui District of Shanghai.
Q: What cooperation mode we could consider?
A: OBM service. We are seeking for a strategic agent or
distributors in each country.
Q: What’s your main products?
A:We are dedicated to three series and five products, which are
Ekeair air sterilizer MKJ4000-S1, MKJ4000-S2, MKJ4000-S4, Ekeair
air sterilizer MKJ-A1, Ekeair air quality monitor SC01.
Q: What is your sole agent policy?
A: An exclusivity agreement would be considered in order to specify
trial order number, first and following stage of purchase number,
marketing period, sales training before marketing etc.
Q: What is your distribution policy?
A: A distribution agreement would be considered in order to specify
trial order number and other conditions.
Q: What about applications?
A: Ekeair air sterilization is suitable for those with high
requirements for air quality, such as inpatient, fever clinic, CT
room, Respiratory room etc. Ekeair has played an important role in
helping with fighting against Covid-19’s bioaerosol.
OBM services: