Data Center Servers Liquid Submersion Cooling System Dry Air Coolers


What's Immersion Cooling?

Also known as liquid submersion cooling. It is the practice of submerging computer components (or full servers) in a thermally, but not electrically, conductive liquid (dielectric coolant) allowing higher heat transfer performance than air and many other benefits.

1. Up to 25% increase in power efficiency

2. Up to 80% cost reduction

3. Up to 60% hashrate increase

4. 50%+ equipment lifespan.


For bitcoin mining farm, if use immersion cooling system, our dry cooler is the most cost-effective way to remove heat and a necessary component of the immersion cooling system, We designed a full range of immersion optimized dry coolers. From 5kW single fan unit to the V-shaped 48-921kW dry coolers. Made in China, sized to your needs.


Also, we have whole immersion cooling system clients, they can also offer the whole system proposal for you.


Why Choose us

Professional system integration

Customized size

Thermodynamic calculations

Authoritative seismic design

Integrated wet curtain celdek7090

Frame:

Galvanized sheet sprayed (rai 7035)

Hot dip galvanized sheet

Stainless steel plate

Galvanized sheet

AC-EC fan:

Protection grade ip55

Low energy consumption

Inverter control

High temperature resistant fan

Explosion-proof fan

Various diameter fans are available:

800, 1~14 psc

910, 1~18 psc

1250, 1~8 psc

1800, 1~7 psc

Pipe:

Copper

Copper nickel alloy

Stainless steel

Titanium

Fin:

Epoxy coating

Aluminum

Copper:

Tinned copper foil

Blygold coating

Stainless steel

Titanium

Overhaul and cleaning:

Easy to clean

Optional access door or hinged fan panel

Fin form for easy cleaning

Robust material with high mechanical strength

Easy to maintain

Different connection options:

Flange connection

Threaded connection

Welding



Options

Coil design refrigerant: water, oil, glycol.Multiple circuits.
Sub-cooling circuits.Stainless steel or aluminum casing.
Coated aluminum or copper fins.Explosion proof motor.
Customized fin spacing.

Technical parameter

Dry cooler D1 series parameter (fin space 2.1mm)

TypeD1-005-1x350D1-006-1x350D1-007-1x350D1-009-1x450D1-011-1x450D1-013-1x450D1-014-1x500D1-017-1x500D1-020-1x500
Capacity
(KW)
Water35℃ outdoor temp.Inlet 45℃4.895.96.839.3910.9913.3314.3217.0119.8
outlet 40℃Y
20% GlycolInlet 45℃4.725.696.698.910.6113.0513.9116.1119.29
outlet 40℃Y
MediumWater flowM3/h0.851.031.21.631.912.32.533.5
Pressure dropkPa363158254080506040
Air flowM3/h282827122492619958275225846981687601
Y
Fan motorPhase111333333
W140140140540540540830830830
Y
A0.60.60.61.11.11.11.451.451.45
Y
FanNo X φ1x1x3501x1x3501x1x3501x1x4501x1x4501x1x4501x1x5001x1x5001x1x500
Sound pressure leveldB(A)313131434343494949
Y10m
DimensionLmm870870870102010201020122012201220
Wmm525525525625625625825825825
Hmm797797797820820820870870870
Amm690690690840840840104010401040
Bmm------------------
Cmm------------------
Dmm490490490490490490490490490
Inlet φmm3/4”3/4”3/4”1”1”1”1-1/4”1-1/4”1-1/4”
Inlet φmm3/4”3/4”3/4”1”1”1”1-1/4”1-1/4”1-1/4”
Product weight(empty)kg384248556067758291

Note: Standard SHSL-D1 dry cooler is vertical air discharge, for horizontal air discharge please add “H” in nomenclature, for excmple:SHSL-D1-005H-1X350


The immersion cooling system diagram by dry cooling tower: