Closed Loop Copper Tube Aluminum Fin Fluid Air Dry Coolers

Brand Name:Shenglin
Certification:CE certification
Model Number:D1 Series
Minimum Order Quantity:1
Delivery Time:35~40days
Payment Terms:T/T, Western Union
Contact Now

Add to Cart

Verified Supplier
Location: Shanghai Shanghai China
Address: Room B321, Building No.1, No. 619, Longchang Road, Yangpu District, Shanghai,China
Supplier`s last login times: within 48 hours
Product Details Company Profile
Product Details

Closed-loop Dry Systems Table Type Copper Tube Aluminum Fin Fluid Cooler


What is closed-loop dry cooling system?


The strength of a closed-loop dry cooling system is that the unit is very simple and relatively easy to install. The energy requirements are relatively low and it is easily controlled. Maintenance is normally low requiring only periodic inspection, lubrication, and testing of the fluid.


The weakness of a closed-loop dry cooling system is that it is dependent on the atmospheric dry bulb. For example, if your location’s design dry bulb is 100 F in the summer and your equipment requires 90 F coolant; at best the system can only supply around 105 to 110 F coolant to the load. In this case you would need supplemental cooling to get the coolant temperatures down to 90 F.


The closed-loop dry cooling system also requires free clear air to work efficiently. This means that the fluid cooler must be placed in a location that is not affected by the prevailing winds, not too close to a building that will allow the warm exhaust air from the fluid cooler to be recirculated back to the fluid cooler, and finally not in a location that has heavy concentrations of dust, dirt, leaves, seeds, etc.


Many times the best location for the fluid cooler is on the roof. Since the fluid cooler is located outside the coolant must also have a concentration of some type of glycol to prevent freezing if your location has a design dry bulb in the winter that dips below freezing. If the location is very cold, the concentration of glycol may need to be significant to prevent freezing. Glycol concentrations as they increase begin to reduce the rate of heat transfer. For example, if you need 50% ethylene glycol concentration with water the heat exchanger equipment and the flow/pressure of the coolant will need to increase to adjust for the glycol concentration. Larger fluid coolers and pumps will increase the cost of the system over those with lesser concentrations of Glycol/water. This cannot be prevented in colder climates.


Dry fluid cooler features:

Air discharge direction
Performance ranges

Cooling capacity: from 5 to 649 kw

Air volume: from 2828 to 263503 m3/h

Sound pressure level: from 31 to 69 dB A(10m)

Dry coolers:customized on demand

High efficiency heat exchanger

Capacity designs for maximizing the heat transfer relative to the energy consumption of the fan.

Tube and tube coupling design for low pressure drop in the coil on the media sides(maximum 100KPa at water designing condition).

Our thermodynamic and aerodynamic designing software is long year tested and proved in Germany

Fan

Only choose low specific energy consumption fans.

Fan nozzle designs for maximum air flow and air throw.

Our fans from the world`s leading manufacturer are practically proved to be reliable in operation and long lasting.

Motor: protection class IP 54 and insulation class F.

Voltage:400V/3N/50Hz

Air separator for each fan.

TestingHeat exchangers are supplied clean and tested at a pressure of 30 bars
Options

Coil design refrigerant: water, oil, glycol.

Multiple circuits.

Sub-cooling circuits.

Stainless steel or aluminum casing.

Coated aluminum or copper fins.

Explosion ploof motor.

Customized fin spacing.



Dry fluid cooler technical parameter

Dry cooler D1 series parameter(fin space 2.1mm)

Type

D1-166-

4x630

D1-211-

6x630

D1-247-

6x630

D1-286-

8x630

D1-334-

8x630

D1-360-

10x630

D1-415-

10x630

D1-502-

12x630

D1-565-

14x630

D1-649-

16x630

CapacityWater35℃ outdoor temp.Inlet45℃,KW165.92211.36247.3286.15334.49359.72415.31502.25565.18649.48
outlet40℃Y134.59176.00200.45238.3270.889298.57335.225405.20459.3527.59
20% GlycolInlet45℃161.32205.08240.46280.05327.72351.3406.48493.40554.21638.44
outlet40℃Y130.96170.87195.07233.18265.64291.81328.48398.45450.87519.13
MediumWater flowM3/h29.003743505863728898113
Pressure dropkPa50704797959270979695
Air flowM3/h67455109723101185146293134908179502164442197326230584263503
Y512658366176900111544102528136437124680149612174710199665
Fan motorPhase3333333333
W1100165001650022000220002750027500330003850044000
Y700105001050014000140001750017500210002450028000
A20.430.630.640.840.851.0051.0061.2071.4081.60
Y12.0018.0018.0024.0024.0030.0030.0036.0042.0048.00
FanNo X φ

2X2

X630

2x3

x630

2x3

x630

2x4

x630

2x4

x630

2x5

x630

2x5

x630

2x6

x630

2x7

x630

2x8

x630

Sound pressure leveldB(A)64666667676868686969
Y10m57595960606161616262
DimensionLmm29304230423055305530683068308130943010730
Wmm2100210021002100210021002100210021002100
Hmm1070107010701070107011201120112011201120
Amm--------------------
Bmm1340134013401340134013401340134013401340
Cmm1300130013001300130013001300130013001300
Dmm640640640640640640640640640640
Inlet φmm3”3”3”DN100DN100DN100DN125DN125

2X

DN125

2X

DN125

Inlet φmm3”3”3”DN100DN100DN100DN125DN125

2X

DN125

2X

DN125

Product weight(empty)kg6586897601105127013201420158418482112

Application:

Industrial field: process engineering, heat / power plant, power generation, chemical industry, air conditioning chiller, heat transformer, sloar system, smelting, etc.. It is suitable for all equipment which needs heat dissipation and is installed in the open air.


Shenglin dry fluid cooler selection software example:


Packing:


China Closed Loop Copper Tube Aluminum Fin Fluid Air Dry Coolers supplier

Closed Loop Copper Tube Aluminum Fin Fluid Air Dry Coolers

Inquiry Cart 0