Blockchain Miners Liquid Submersion Cooling System Dry Cooling Tower

Blockchain Miners Liquid Submersion Cooling System Dry Cooling Tower

Brand Name:Shenglin
Certification:CE
Model Number:SHSL-D1 Series
Minimum Order Quantity:1
Delivery Time:30~35days
Payment Terms:T/T, Western Union
Contact Now

Add to Cart

Verified Supplier
Location: Shanghai Shanghai China
Address: Room B321, Building No.1, No. 619, Longchang Road, Yangpu District, Shanghai,China
Supplier`s last login times: within 48 hours
Shipping
lt's easy to get a shipping quote! Just click the button below and complete the short form.
Get Shipping Quote
Product Details Company Profile
Product Details

Blockchain Miners Liquid Submersion Cooling System Dry Cooling Tower


What's Immersion Cooling?

Also known as liquid submersion cooling. It is the practice of submerging computer components (or full servers) in a thermally, but not electrically, conductive liquid (dielectric coolant) allowing higher heat transfer performance than air and many other benefits.

Why many large data centers have already moved or are considering the move to immersion cooling?

1. Save floor space. Compare with traditional forced air cooling way(using precision air conditioner), immersion cooling system will save much floor space. Because no need rack system and no need air conditioner indoor.

2. Save power. Compare with traditional forced air cooling way(using precision air conditioner), immersion cooling system will save much power. For example, no need to install many air conditioners indoor, then no compressor power consumption. For example, the bitcoin miners no need air cooling fans. Thesewill save power around 18~25%.

3. Increase hardware lifepan. In immersion, machines operate in a 100% controlled environment with no dust, no temperature of humidity fluctuations, no impurities. This will extend the service life of the mining machine or server. This will also reduce machine maintainance fee.

4. Increase hashrate of the mining machine.

For bitcoin mining farm, if use immersion cooling system, our dry cooler is the most cost-effective way to remove heat and a necessary component of the immersion cooling system, We designed a full range of immersion optimized dry coolers. From 5kW single fan unit to the V-shaped 48-921kW dry coolers. Made in China, sized to your needs.


Also, we have whole immersion cooling system clients, they can also offer the whole system proposal for you.


Features


Dry coolers use ambient air to cool process fluids. Multiple units can be employed to handle even greater heat loads. Configuration choices include horizontal or vertical air discharge, single or double row fans, and vertical, horizontal or V mounted coils. Units can have multiple circuits, multiple passes and can be configured to be piped in series or parallel. The rugged, weather-proof design is manufactured with corrosion-resistant galvanized steel sheet, finished with high quality polyurethane paint. Standard cooling coils consist of copper tubes and aluminum fins, which are coupled with high efficiency, low noise fans. A variety of optional fan controls can be provided, including step controls and variable speed drives in single- and three-phase voltages to match your electric power supply.


Technical parameter

Dry cooling tower D2 series parameter(fin space 2.1mm)

Type

D2-148-

4x630

D2-166-

4x630

D2-175-

4x630

D2-228-

6x630

D2-250-

6x630

D2-276-

6x630

D2-310-

8x630

D2-343-

8x630

D2-364-

8x630

D2-392-

10x630

CapacityWaterKW147.99165.85175.21227.85250.42276.53309.85342.73364.07391.99
20% Et. GlycolKW142.42161.57170.91219.09244.69270.22301.18333.55354.64383.3
Air flowM3/h764597434172134114686111511108188152911148675144255191136
FanNo. X φ2x2x6302x2x6302x2x6302x3x6302x3x6302x3x6302x4x6302x4x6302x4x6302x5x630
Fan motorA20.420.420.430.630.630.640.840.840.851
400/3N/50HZ
Sound pressure leveldB(A)10m64646466666667676768
DimensionLmm2186218621863250325032504250425042505250
Hmm1874187418741874187418741874187418741874
Dmm2100210021002100210021002100210021002100
D1mm2000200020002000200020002000200020002000
L1mm963963963963963963963963963963
L2mm1000100010001000100010001000100010001000
L3mm1963196319632963296329633963396339634963
Connections inlet φmm2XDN502XDN652XDN652XDN652XDN802XDN802XDN802XDN802XDN1002XDN100
Connections onlet φmm2XDN502XDN652XDN652XDN652XDN802XDN802XDN802XDN802XDN1002XDN100
Product weight(empty)kg7698118531134119712611498158916731864

Reference:

Dry cooling tower case
Case 1: used in chemical plant.

Case 2: used in chemical plant. Refrigerant: ethylic acid(flow: 372 ton/h)


Case 3: used in communication station as air conditioner outdoor unit in China.

Case 4: used in communication station as air conditioner outdoor unit


China Blockchain Miners Liquid Submersion Cooling System Dry Cooling Tower supplier