ISO14001 Standard Clean Room Air Conditioning System Air Handler

Brand Name:Shenglin
Certification:CE
Model Number:SL-ZKW Series
Minimum Order Quantity:1
Delivery Time:35~40days
Payment Terms:T/T, Western Union
Contact Now

Add to Cart

Verified Supplier
Location: Shanghai Shanghai China
Address: Room B321, Building No.1, No. 619, Longchang Road, Yangpu District, Shanghai,China
Supplier`s last login times: within 48 hours
Product Details Company Profile
Product Details
ISO14001 Standard Clean Room Air Conditioning System Air Handler
The combined air handling untis are modular designed ,each modular can be used independently and can also work together and company with fan coil units to add refresh air. Not only reduce operation costs and energy saving, but also optimize air quality and create a congnitive indoor space to meet the human health requirements.
Feature:
1, Complying with above China Standard, which is from ARI standard. ISO9001 and ISO14001 qualified.
2, Choose best materials, main components are from China top brand or imported.
3, The modular casing design, easy interchanging each other. easy install,easy transport,easy maintaince.
4, Unique no-cold-bridge design, improve the insulation and air tightness, total air leak rate ≤2.5%;
5, With dynamic balanced double inlet Centrifugal fan, with good air dynamic features, and accurate working, high efficiency, low vibration, low noise etc.
6, High efficient heat exchanger coil, ensure to provide the enough cooling capacity to the unit. And also high efficient breakwater panel is provided if required, water flow in coil ≤3×10-4kg/kg
7, Strong structure, good looking and permanent color.
8, Reasonable inside structure, with the suitable space for maintenance and cleaning.
9, Casing sheet: Provide double-skin construction constructing Sandwich type comprising 0.5mm thick galvanized internal and external skins and with 30mm thick polystyrene insulation of minimum 45kg/m3 density. Good airproof material is use between the casing and the frame to reduce the rate of the air leak.
Technical Data:
Chilled Water Air Handing Unit Spec. Table No. 2
Model SL-ZKW-()CW3003504004505005506007008001000
Air volume(m³/h)300003500040000450005000055000600007000080000100000
Outlet air pressure(pa)600600600600600800800800800800
Supply fan capacity(kw)18.518.52222303037374555
Heating capacity(kw)728496961201120150180180210
Heating capacity(kg/h)2130304545607290100120
Filter typePre-filter G4 (Med-filter F8 / Nano carbon filtration)
Power3N-380V-50Hz
Cooling4 Rows Return AirReturn air(kw)179210245277306340375440504590
water flow(m³/h)28.236.242.147.65358.264.676.186.8101.3
water resistance(m³/h)50202729323540253548
pipe diameter (DN)8065*265*280*280*280*280*2100*2100*2100*2
4 Rows Fresh AirAll fresh air(kw)3103604104565105706007208401020
water flow(m³/h)5562.572.278.487.698103.1123.7144.3175.3
water resistance(m³/h)35403138434836483550
pipe diameter (DN)80*280*2100*2100*2100*2100*280*380*3100*3100*3
6 Rows Return AirReturn air(kw)210240280310350380400490560680
water flow(m³/h)3642.548.152.3606668.884.296.6116.8
water resistance(m³/h)250.33540492634393240
pipe diameter (DN)10065*580*280*280*2100*2100*2100*280*380*3
6 Rows Fresh AirAll fresh air(kw)42045653259066572076093010601290
water flow(m³/h)72.578.491.4101114.3123.7130160182221.6
water resistance(m³/h)40455038424831405045
pipe diameter (DN)100*2100*2100*280*380*380*3100*3100*3100*3125*3
8 Rows Return AirReturn air(kw)264290330380420470480590680820
water flow(m³/h)44.249.856.765.372.780.882.5101.4116.8141
water resistance(m³/h)29354031364245304042
pipe diameter (DN)80*280*280*2100*2100*280*280*280*280*2100*3
8 Rows Fresh AirAll fresh air(kw)500550630720800890910112012901560
water flow(m³/h)8594.5108.3123.7137.51531564192.5221.7268
water resistance(m³/h)40384650384535404542
pipe diameter (DN)100*280*380*380*3100*3100*3100*3125*3125*3100*4
Heating2 Rows Return AirReturn air(kw)17019923526029032350408467565
water flow(m³/h)151720232527.530354049
water resistance(m³/h)11.5161421221520263224
pipe diameter (DN)6565808080100100100
2 Rows Fresh AirAll fresh air(kw)256298349392426468500598685793
water flow(m³/h)222530343710.343525949
water resistance(m³/h)20242514.514.9192217.81516
pipe diameter (DN)8080100100100125180210100*2
4 Rows Return AirReturn air(kw)2703163704154.55.57.810739855
water flow(m³/h)23.527.532364040505064.676.1
water resistance(m³/h)16131211014020025032010.520
pipe diameter (DN)80801004.86.391113.518.2
4 Rows Fresh AirAll fresh air(kw)40047054861667075082297210951340
water flow(m³/h)354047535864.6718494115
water resistance(m³/h)20172427272931354225
pipe diameter (DN)1005680110140200250320380
Section
size
StandardLength(mm)1960227022702580258032703270327032703825
height(mm)204023402340265026502650265334033403340
Function
section
Mixing sectionLength(mm)800100010001000120012001200120012001200
Pre-filter sectionLength(mm)100100100100100100100100100100
Med-filter sectionLength(mm)500500500500500500500500500500
Cooling coil sectionLength(mm)1000120012001200120012001200120012001200
Heating sectionLength(mm)100500500500500600600600600600
Humidifying sectionLength(mm)600600600600600600600600600600
Fan sectionLength(mm)1850200020002000200022002200230027002700
Current balance sectionLength(mm)700800500800800800800800800800
Sound deadening sectionLength(mm)1000120012001200120012001400140014001400
Sterilization sectionLength(mm)600600600600800800800800800800
Air outlet sectionLength(mm)8001000100100120012001500150015001500
1. Cooling condition: supply and return water temp7/12℃,
indoor dry bulb/ wet bulb temp35/28℃, fresh air dry bulb/ wet bulb temp35/28℃

2. Heating condition conditions: supply and return water temp60/50℃,
indoor dry bulb/ wet bulb temp20/ -℃, fresh air dry bulb/ wet bulb temp7/6℃

3. The air volume, residual pressure and power in the table are standard parameters,
and are able to be customized

4. Heater, humidifier and heat recovery device are optional, which can be configured as spacific form according to customer's requirements

5. G4 filter is adopted as the unit standard, which can be configured as other form according to customer's requirements

6. The length and size are determined by the functional sections. Please consult us for details.


Application:

The units are widely used in the air system of many inductries like mechanical ,electronic, textile,medical,chemical,energy and foo inductries ,etc. the units are also ideal solution for restaurants, office buildings,hospitals,theaters,supermarkets and palaestra.

China ISO14001 Standard Clean Room Air Conditioning System Air Handler supplier