Add to Cart
Model | MIC600S |
Measuring range | 0.01~ 10/100 / 1000 PPm O2 ; |
Accuracy | ≤±2%FS; |
Stability | zero drift ≤ ± 1 % FS/7d; Range drift ≤ ±2% FS/7d; |
Repeatability | ≤±1%; |
Sample gas flow rate | 400 ~ 500 ml/min; |
Response time | T95 < 5s; |
Sample gas pressure | inlet pressure ≤ 0.5MPa; |
Minimum resolution | 0.01 ppm ; |
Control output | dual relay contact output, can be set arbitrarily; |
Contact capacity | 220VAC 2A; 24VDC 2A; |
Analog output | 4~20mA current signal; |
Overall dimensions | 244 (width) × 142 (height) × 230 (depth); |
Opening size | 210 + 1 (width) × 132 + 1 (height); |
Working environment | Temperature: -5℃~+50℃; Humidity: ≤90%RH; |
Working power supply | 100 ~220V AC , 50/60HZ; |
Fuse | 220V/1A (built into the power socket, one for backup); |
Weight | about 3 kg ; |
MIC600S Trace Oxygen Analyzer is a high-precision, online instrument developed by our company for detecting and analyzing trace oxygen in inert gases. This instrument utilizes an electrochemical sensor combined with single-chip microcomputer control technology, resulting in high measurement accuracy and ease of use. The instrument features a 3.5-inch touchscreen display with a narrow viewing angle and is intuitive and eye-catching. Its fully Chinese menu operation is easy to understand, simple, and reliable. It features control point output, an over-limit self-alarm (buzzer), and customizable control modes. It also includes a standard 4-20mA current output port and other external connections. When unattended, it can periodically record measurement values. When a measurement result exceeds the set alarm value , the instrument automatically alarms.