HiYi Portable 5 Gas Analyzer High Sensitivity Built-In Pump CO H2S O2 EX CO2 Multi Gas Detector


HiYi MS500 Portable Gas Detector


5 in 1 | Internal Pump | Large Data Storage

OVERVIEW


Clearance measurement was never this easy and convenient!


MS500 series is suitable for detecting the concentrations of gases in the atmosphere environment in the pipeline or confined space. The types for detection are more than 500 types.


It is suitable for detecting the concentrations of gases in the atmosphere environment in the pipeline or confined space; and the purity of the gas leakage and various high concentration single gases with the background gas as nitrogen gas or oxygen gas.


FEATURES & BENEFITS


  • It is possible to simultaneously detect 1 ~ 5 types of gases, and the types for detection are more than 500 types.
  • There are 7 gas units to display, and the units can be switched freely. Units that can be selected: PPM, mg/m3, Vol%, LEL%, PPHM, ppb, mg/l.
  • 2.5-inch high-definition color screen, display the information such as real-time concentration, alarm, time, temperature,
  • humidity, storage, and so on; the menu interface adopted high definition simulation graphics to display the function name of each menu.
  • Graphical display, and use the form of curve to reflect the trend of gas concentration changes in a certain period of time.
  • Simultaneously display the concentrations of five types of gases, repeatedly display the concentration of single-channel gases in large font, and display the real-time curve. And it is possible to switch among three display modes.
  • Standard configuration is the data storage capacity for 100, 000 entries; real-time storage and fixed time storage are supported, or only the data of the alarm concentration will be stored. Large capacity can be customized.
  • It is supported to use the local host to view, and delete data, and upload the data via USB, RS232 interface or infrared
  • communication to the computer for data analysis or printing.
  • Built-in humidity dust filter, preliminary treatment of the detection gas, so as to protect the equipment.
  • Multiple alarm modes, and multi-directional and three-dimensional indication alarm states. It includes sound & light alarm, vibration alarm, display screen visual alarm.Alarm types include: concentration alarm, under-voltage alarm, and failure alarm. Multiple alarm mode settings: low alarm, high alarm, interval alarm, and weighted average alarm.
  • Zero-point automatic tracking; long-term use will not be affected by the zero drift.
  • Multi-level calibration for target points, can ensure the linearity and accuracy of the measurements.
  • Log recording Record the calibration logs, repair logs, failure history, failure countermeasure solutions, sensor service life due reminder, and function of reminder for the time of next concentration calibration.
  • Data recovery function; in case of mis-operation, it is possible to select partial or full recovery.
  • Mis-operation recognition function: automatic recognition and prevention of the concentration calibration mis-operation, which is possible to avoid the poor performance that may be caused by human factors.
  • Temperature and humidity measurement function
  • 1.2 m retractable sampling handle (1-10 meter hose, and the standard length is 1 meter)
  • 0.4 meter stainless steel sampling handle (with dust filter, not retractable)
  • High temperature sampling and cooling filter handle
  • High temperature humidity pretreatment system
  • Multiple humidity dust filter
  • Hanging rope
  • CD-ROM (upper level computer communication software)
  • External mini wireless infrared printer
SPECIFICATION

Gases to be detected

Arbitrary combination of 1 ~ 5 types of gases such as toxic gases, oxygen gas, carbon dioxide, inflammable and explosive gases, TVOC, and so on.

Optional configuration: temperature and humidity measurements.

Application scenariosAll the cases which requires the portable rapid detection of gas concentrations such as petroleum, chemical, pharmaceutical, environmental protection, combustion gas distribution, warehousing, smoke gas analysis, air governance, and so on.
Detection range0 ~ 1, 10, 100, 1000, 5000, 50000, 100000ppm, 200 mg/L, 100%LEL, 20%, 50%, 100%Vol, can be selected; and other ranges can be customized.
Resolution

0.01ppm or 0.001ppm (0 ~ 10 ppm);

0.01ppm (0 ~ 100 ppm),

0.1ppm (0 ~ 1000 ppm),

1ppm (0 ~ 10000 ppm or more),

0.01 mg/l (0 ~ 200 mg/l),

0.1% LEL,

0.01%,

0.001% Vol

Detection principleElectrochemical, catalytic combustion, infrared, thermal conductivity, PID photoionization, and so on, depending on the type of gas, range, field environment and user demand.
Sensor service lifeElectrochemical principle: 2 ~ 3 years; Oxygen gas: 2 years or 6 years can be selected; infrared principle: 5 ~ 10 years; catalytic combustion: 3 years; thermal conductivity: 5 years; PID photoionization: 2 ~ 3 years.
Allowable error≤±2% F.S (other or higher precision levels can be customized)
Linearity≤±2%Repeatability≤±2%Uncertainty≤±2%
Response timeT90≤20 secondsRecovery time≤30 seconds
Working environmentTemperature: -40 ℃ ~ + 70 ℃, humidity: ≤10 ~ 95% RH, and built-in filters can be used in high humidity or high dust environment.
Sample gas temperature-40 ℃ ~ + 70 ℃, and the optional configuration of high-temperature sampling and cooling filter handle will be possible to detect the smoke gas at the temperature of 800 ℃ or higher.
Temperature and humidity measurementOptional configuration: temperature at -40 ℃ ~ + 70 ℃, accuracy level at 0.5 ℃; humidity at 0 ~ 100% RH, precision level at 3 % RH
Power supply3.6VDC, 5500mA high capacity rechargeable polymer battery
Display mode2.5-inch high-definition color screen
Detection modeBuilt-in pump-suction type measurement, and flow rate at 500 ml / min. Calibration flow rate should be greater than 500 ml / min, three-way pipe should be connected, so as to ensure that the excessive gas will be discharged from the bypass
Alarm modeIt is possible to set as sound & light alarm, vibration alarm, sound & light + vibration alarm, Turning off the alarm.
Communication interfaceUSB (charging and communication), optional: RS232, infrared communication, automatic recognition
Data storageStandard configuration is the data storage capacity for 100, 000 entries
Protection levelIP66
Explosion-proof typeIntrinsically safe type
Explosion-proof markExia II CT6
Exterior dimensions180×78×33mm (L×W×H)
Weight350g
Standard accessoriesManual, qualification certificate, warranty card, USB charger (including the data cable), high-grade aluminum instrument case, belt clip, humidity dust filter
Optional itemsTemperature and humidity measurement function, 1.2 m retractable sampling handle (1-10 meter hose, and the standard length is 1 meter), 0.4 meter stainless steel sampling handle (with dust filter, not retractable), high temperature sampling and cooling filter handle, high temperature humidity pretreatment system, multiple humidity dust filter, hanging rope, CD-ROM (upper level computer communication software), external mini wireless infrared printer