TU5200 Laboratory Laser Turbidimeter Without RFID EPA Version

Brand Name:HiYi
Certification:CE
Model Number:TU5200
Minimum Order Quantity:1
Delivery Time:3-7 days
Place of Origin:China
Contact Now

Add to Cart

Verified Supplier
Location: Beijing Beijing
Address: Room 1302,Yufei Building, 42 Dongzhimenwai Street, Dongcheng District, Postcode:100027 Beijing,China
Supplier`s last login times: within 48 hours
Product Details Company Profile
Product Details

TU5200 Laboratory Laser Turbidimeter


OVERVIEW

The platform employs a patented optical design that sees more of your sample than any other turbidimeter, delivering the best low level precision and sensitivity while minimizing variability from test to test. For the first time you will be able to remove the uncertainty of which measurement to trust, thanks to identical 360° x 90° Detection Technology in both instruments. The TU5 Series dramatically reduces the time needed to get a turbidity measurement you can rely on. The TU5200 Lab Turbidimeter, with the 360° x 90° Detection Technology, sees more of your sample meaning you no longer have to apply silicone oil to your vial and index to ensure an accurate reading. In addition, you can have confidence that you will get consistent results in the lab, from operator to operator, since the impact of small interferences is minimized due to the collection of light at 360°.


FEATURES

Groundbreaking 360° x 90° Detection™ Technology:
The TU5 Series employs a patented optical design that sees more of your sample than any other turbidimeter, delivering the best low level precision and sensitivity while minimizing variability from test to test.


Matching lab and online results:
For the first time you will be able to remove the uncertainty of which measurement to trust, thanks to identical 360° x 90° Detection™ Technology in both instruments.


Everything about turbidity – faster:
The TU5 Series dramatically reduces the time needed to get a turbidity measurement you can rely on, with 98% less online sample surface area to clean, sealed vials for calibration, and the elimination of the need for indexing and silicone oil in the lab. Not to mention, a smaller online sample volume means you will detect events almost immediately.


SPECIFICATION

Loadi
Accuracy±2 % plus 0.01 NTU from 0 - 40 NTU;
±10 % of reading from 40 - 1000 NTU based on Formazin primary standard (at 25 °C)
Calibration MethodFor Formazin and Stablcal:
20 NTU from 0 to 40 NTU; at 20 FNU and 600 NTU for full range

Custom calibration for up to 6-point calibrations

Degrees 0 - 100 mg/L
SDVB 0 - 1000 NTU
CertificationsCE compliant
US FDA accession number: 1420493-000 EPA version, 1420492-000 ISO version
Complies with IEC/EN 60825-1 and to 21 CFR 1040.10 in accordance with Laser Notice No. 50)
Australian ACMA Marking
CommunicationLink2sc
Dimensions (H x W x D)195 mm x 409 mm x 278 mm
Display7" WVGA (800 x 480) color TFT-LCD with touch screen
Enclosure ConstructionPC/ABS Blend Plastic
Light SourceClass 2 laser product, with embedded 650 nm (EPA 0.43 mW) or Class 1 laser product, with embedded 850 nm (ISO), max. 0.55 mW (complies with IEC/EN 60825-1 and to 21 CFR 1040.10 in accordance with Laser Notice No. 50)
ModelTU5200 EPA
Operating Humidity80 % at 30 °C (non condensing)
Operating Temperature Range10 - 40 °C
Power Requirements (Hz)50/60 Hz
Power Requirements (Voltage)100 - 240 VAC
RangeEPA:
0 - 700 NTU / FNU / TE/F / FTU
0 - 100 mg/L
0 - 175 EBC

ISO:
0 - 1000 NTU / FNU / TE/F / FTU
0 - 100 mg/L
0 - 250 EBC
RegulatoryEPA
Repeatability<40 NTU: Better than 1% of reading or ±0.002 NTU on Formazin at 25 °C (77 °F), whichever is greater
>40 NTU: Better than 3.5% of reading on Formazin at 25 °C (77 °F)
Resolution0.0001 NTU / FNU / TE/F / FTU / EBC / mg/L
Response TimeSignal averaging off: 7 seconds
Signal averaging on: 10 seconds (when averaging time is 5 seconds)
Sample Temperature4 - 70 °C
Source Lamp650 nm Class 2 Laser
Storage Conditions-30 - 60 °C (-22 - 140 °F)
Stray Light<10 mNTU
UnitsNTU, FNU, TE/F, FTU, EBC;

mg/L if calibrated with Degrees calibration curve
What's included?TU5200 benchtop turbidimeter, user manual, Stablcal kit (10, 20 and 600 NTU), 2 sample vials, power supply, dust cover, vial stand

China TU5200 Laboratory Laser Turbidimeter Without RFID EPA Version supplier