GE HealthCare Voluson E8 RSX20 Extension Board
1. Lead time: 2-4 days
2. Warranty: 60 days
3. Part number: KTI303054-14
Picture
Related information
About the VOLUSON E8
1.Equipment characteristics
Advanced image optimization tools:
Speckle Noise Suppression Technique III (SRI-III) : Improved
imaging of tissues and lesions with higher detail contrast
resolution while preserving true tissue structure while suppressing
speckle noise.
crossXBeam (CRI) is a spatial composite imaging technology with
unique spatial composite image acquisition and processing
capabilities to enhance tissue and boundary identification.
High-resolution blood flow imaging technology HD-Flow: Through the
use of two-way energy Doppler technology, increase the sensitivity
of blood vessel examination, overcome the weakness of standard
color Doppler blood flow leakage.
B-Flow: Displays true hemodynamic information and can be directly
observed by amplifying blood cell reflexes by a factor of 1000.
Volume imaging tools:
Tomographic ultrasonography (TUI) makes it easier to analyze and
record dynamic data by simultaneously displaying multiple sections
of volume data.
Spatial-temporal Image Correlation Technology (STIC) : Helps
clinicians obtain complete fetal cardiac cycle image information
quickly and in real time, and store the original image for
subsequent analysis.
Volume contrast imaging (VCl) : By optimizing the image quality of
three different planes, the size, boundary, and internal structure
of the lesion can be better evaluated.
Fetal heart assessment techniques:
SonoVCAD (Ultrasound based Volume Computer Aided Diagnostic System)
: helps in the standardized acquisition of fetal heart examination
images by automatically acquiring fetal heart volume images.
Advanced STICM, SonoVCAD heart, and STICM technologies are also
included to provide a cardiographic-like view of the fetal
cardiovascular system.
2. Scope of application
The VOLUSON E8 color Doppler ultrasound diagnostic system is
suitable for multiple clinical areas, including obstetrics and
gynecology, cardiac function, peripheral blood, abdomen, small
organs, neurology, urology, pediatrics, and more. Especially in the
field of obstetrics and gynecology, the device provides clear
two-dimensional images and advanced fetal heart evaluation
technology, providing clinicians with strong diagnostic support.
3.Precautions
When using VOLUSON E8 or other medical devices for diagnosis,
ensure that proper procedures are followed and that they are
performed by trained personnel to avoid misdiagnosis or missed
diagnosis.
When purchasing and using the device, consumers should carefully
read the product manual or under the guidance of medical personnel.
In summary, the VOLUSON E8 color Doppler ultrasound diagnostic
system plays an important role in clinical diagnosis with its
advanced image optimization tools, volume imaging tools and fetal
heart evaluation techniques. At the same time, the device is also
suitable for multiple clinical areas, providing clinicians with
comprehensive diagnostic support.
About the VOLUSON E8 RSX20 Extension Board
1. Role and Function
Beamforming: Beamformer Board is a key component in ultrasound
diagnostic equipment. It is mainly responsible for processing the
ultrasound signal received by the probe. Through beamforming
technology, the signals received by multiple array elements are
phase adjusted and weighted summed, thereby enhancing the target
signal and suppressing noise.
Improving image quality: Through precise beamforming, the board can
significantly improve the resolution, contrast and signal-to-noise
ratio of ultrasound images, providing doctors with clearer and more
accurate diagnostic basis.
2. Technical features
High precision: As an advanced ultrasound diagnostic instrument, GE
Voluson E8 uses high-precision electronic components and algorithms
in its Beamformer Board to ensure the accuracy and stability of
beamforming.
Real-time processing: In order to meet the needs of real-time
imaging, Beamformer Board needs to have high-speed processing
capabilities and be able to complete the calculation and processing
of large amounts of data in a short time.
Programmability: With the continuous development of ultrasound
technology, Beamformer Board is usually programmable to adapt to
changes in different imaging modes and clinical needs.
3. Maintenance and Care
Regular cleaning: To ensure the normal operation of the Beamformer
Board, the ultrasound diagnostic instrument needs to be cleaned
regularly to prevent dust and dirt from damaging the equipment.
Avoid vibration: During use, avoid strong vibration or impact on
the ultrasound diagnostic instrument to avoid damage to precision
parts such as the Beamformer Board.
Professional maintenance: If the Beamformer Board fails or needs
maintenance, it should be operated by a professional to ensure the
safety and reliability of the equipment.
Other ultrasound parts related to GE that we can offer:
Brand | System | Description | Part Number |
GE | Logiq P5 | APS Power Supply | 5140505/5166108/5329667 |
GE | Logiq P5 | CPU mainboard | 5168431 |
GE | Logiq P5 | SYSCONPM | 5177848-3 |
GE | Logiq P6 | CPU Mainboard | |
GE | Logiq P6 | PST Power Supply | 5245004/5244555 |
GE | Logiq P6 | SYSCONML | 5252326-3 |
GE | Logiq S7/Logiq S8 | CPS Power supply | 6626600 R02/5413249-3 |
GE | Logiq S7 | BF128 transmitting board | 5392446 |
GE | Logiq S7 | GFS board | 5371196 |
GE | Logiq S8 | BF192 Beamformer | 5357234-2 |
GE | Logiq S8 | GFS board | 5371196-2/5455247 |
GE | Logiq E9/vivid E9 | GTX | GA200726 |
GE | Logiq E9 | MRX Board | 5393908/5393912 |
GE | Logiq E9/vivid E9 | GFI2 | 5161631 |
GE | Logiq E9 | BEP Power Supply | 5393800-3/5166790-2 |
GE | Voluson E6/Voluson E8 | RSR | KTI301394-2/KTI196357 |
GE | Voluson E6/Voluson E8 | RST | KTI301148 |
GE | Voluson E6/E8/E10 | RSX | KTZ303054 /KTI303054 |
GE | Voluson E6/E8/E10 | RFM201 FE mainboard | KTZ303916 |
GE | Voluson E6/E8/E10 | RFM221 FE mainboard | KTZ303915 |
GE | Voluson E6/Voluson E8 | RFI/ RFI21b Board | KTI300614/KTI302197-6 |
GE | Voluson S6/S8/P8 | BF64 | 5396937-2 |
GE | Voluson S6/S8/P8 | BF128 | 5338209-2 |
GE | Voluson S6/S8/P8 | CPS Power supply | 5393431 |
GE | Voluson S6/S8/P8 | RFS board | 5364098-2/5364098-3 |
GE | Voluson S6/S10/P8 | BF192 board | 5357234 |