Hospital UST-9104-5 Micro Convex Probe 7.5 MHz Ultrasonic Transducer

Brand Name:Aloka
Model Number:UST-9104-5
Minimum Order Quantity:1
Delivery Time:1-3 work days
Payment Terms:T/T, Western Union
Price:Negotiable
Contact Now

Add to Cart

Verified Supplier
Location: Guangzhou Guangdong China
Address: Room 201, 203, Building C ,No. 26, Ningcai Road, Huangpu District, Guangzhou, China
Supplier`s last login times: within 16 hours
Product Details Company Profile
Product Details

ALOKA UST-9104-5 Micro Convex Probe


1. Type: Curved Array
2. Frequency: 3.0 - 7.5 MHz.

3. Application: Neonatal

5. Compatible with Aloka SSD-900; Aloka SSD-1400; Aloka SSD-1700; Aloka SSD-1000; Aloka SSD-3500
6. Warranty: 60 days
7. Lead time:1-3 days




Ultrasound Machine Maintenance


1. Check the Ultrasound Machine Daily

Before starting the examinations of your patients, ensure that all the connections of the ultrasound are plugged in properly. You should look carefully at the integrity of the ultrasound wiring, cables as well as transducers. If you find any cut or frayed areas, replace them with backup supplies immediately.


2. Pay Attention to Your Ultrasound Transducers

Ultrasound transducers are a vital part of a fully functional ultrasound unit. They need to be checked correctly to make sure that doctors can get precise examination results.

Therefore, perform a visual check of the probe and its connection to the ultrasound machine before each use. Inspect if there are any cracks/cuts on the probe lens or on the TEE probe tube. That is important because ultrasound gel or disinfectant can easily seep into the cuts and potentially damage the transducer. Furthermore, look for tears in the cable that could indicate broken wires inside the transducer.

Lastly, follow cleaning protocols, for instance, the sterilization of certain types of probes used for specific procedures. And be aware of the detergents your sonographer is using when cleaning and disinfecting the probes. Be sure that they are compatible with the probe manufacturer’s recommendations to avoid unwanted damages.


Other Aloka probes we can offer:


BrandModelCompatible System
AlokaUST-979-3.5SSD-900/1000/1100/1400/1700/3500/4000
AlokaUST-944B-3.5SSD-500/SSD- 620/SSD- 625/SSD-650/SSD-1100
AlokaUST-669-5-7.5SSD-1000/ SSD -1700/ SSD -2200
AlokaUST-984-5SSD-1000/SSD-1400/SSD-1700/SSD-5000/SSD-5500
AlokaUST-9115-5SSD-5000/ Alpha 5/ Alpha 10
AlokaUST-9116P-5SSD-1000
AlokaUST-9118Alpha 5/Alpha 10/SSD-3500/SSD-4000/SSD-5500
AlokaUST-9120Alpha 5/Alpha 7/Alpha 10
AlokaUST-9121SSD-3500/SSD-4000
AlokaUST-9123SSD-4000/ SSD-3500
AlokaUST-9124SSD-3500/SSD-4000
AlokaUST-9126SSD-5000/ SSD-5500/Alpha 5
AlokaUST-9130Alpha 7/Alpha 10
AlokaUST-5410HAlpha 5 Ver. 3.1 and above
AlokaUST-5294SSD-5000
AlokaUST-5546SSD-3500/SSD-4000
AlokaUST-5266-3.5SSD-1700/SSD- 2000/SSD- 2200
AlokaUST-5283-2.5SSD-2000/SSD-2200
AlokaUST-5299SSD 3500/4000/Prosound Alpha 6
AlokaUST-5412Alpha 5/Alpha 10/SSD-500V/SSD-5500
AlokaUST-5413SSD-3500/SSD-4000
AlokaUST-5518-7.5SSD-3500/SSD-4000
AlokaUST-5524-7.5SSD-1000/1400/1700/5000/5500
AlokaUST-5524-5SSD-1000/1400/1700/5000/5500
AlokaUST-5536-7.5SSD-1700/SSD-2000/ProSound SSD-3500/ SSD-4000/ Alpha 5
AlokaUST-5543Alpha 5/Alpha 10
AlokaUST-5548Alpha 5SX/Alpha 7/Alpha 10/SSD-3500SX
AlokaUST-5710-7.5SSD-900/SSD-1000/SSD-1400/SSD-1700/SSD-3500/SSD-4000/Alpha 5
AlokaUST-5712Alpha 5/ Alpha 7/ Alpha 10
AlokaUST-52101Alpha 5/Alpha 7/SSD-5500
AlokaUST-52105Alpha 5/ Alpha 7/ Alpha 10
AlokaUST-52108SSD-5500
AlokaUST-52109Alpha 5/SSD-4000