GE RM6C 4d Probe Repair Motor Control Failures


Repair 3D/4D GE RM6C Motor/Diagnostic Medical Device Service


Motor control failures


If the array stops moving or gets stuck, the motor control function has failed and may need to be repaired or replaced.


Solution

Motor repair





Other hot GE models we can repair:


GEC1-5-D
GEC1-5-RS
GE4C
GE4C-RS
GE4C-A
GE4C-D
GE4C-SC
GEE8C/E8C-RS
GEE8CS
GERIC5-9-D
GE3CRF-D
GEC1-6-D
GERAB4-8-RS
GERAB2-5-RS
GE6S-RS
GE12L-RS
GE3SC-RS
GEL6-12-RS
GE11L
GE11L-D
GE12L-RS
GE8C
GE3S
GE3S-RS

Common ultrasound Probe Damage(Specialty 3D/4D Volume probes)


Common ultrasound probe damageSolutions
Lens cap damageLens cap replacement
Fluid and oil leaksLens cap replacement, oil reservoir repair and replacement
Cable cutsCable patches, possible cable replacement
Inoperative steeringMotor repair
Connector housing electrical damageMinor electrical repairs, pin module replacement
Weak or dead elements, dropouts in an imageArray ball replacement, oil reservoir repair and replacement

Warnings and cautions of ultrasonic probe


The ultrasonic probe is a valuable device. It must be careful in the process of use. Avoid dropping, impact, or abrasion to transducers.

When installing or removing the probe, first switch off the power and then operate it carefully.

Avoid rapid and extreme temperature changes, as well as lengthy exposure to direct sunlight or a strong ultraviolet light source.

Do not use sharp objects to penetrate the acoustic lens.Once the acoustic lens is damaged, the coupling gel is easy to enter the interior of the probe and damage the piezoelectric element.

Do not soak transducer in any liquid above the recommended level as stated in the user manual for your system, please operate according to the manufacturer's instructions, otherwise it will lead to circuit failure or even burn out.

Do not disinfect at high temperature, because the probe is equipped with piezoelectric ceramics, high temperature will weaken the effect.

Before use, carefully check whether the housing and cable are damaged, so as to prevent the probe from high voltage injury.

After the probe is used, the residual coupling gel on the probe must be wiped clean to prevent rats or other animals from gnawing the lens.


Storage for Transport of ultrasonic transducer

  • Make sure that the transducer is clean and disinfected before placing it in the case to avoid contaminating the foam that lines the carrying case.
  • Place the transducer in the case carefully to prevent kinking of the cable.
  • Before closing the lid, make sure no part of the transducer is protruding from the case.
  • Wrap the case in plastic material containing sealed-air pockets (such as Bubble Wrap material), and pack the wrapped case in a cardboard carton.
China GE RM6C 4d Probe Repair Motor Control Failures supplier

GE RM6C 4d Probe Repair Motor Control Failures

Inquiry Cart 0