Home /Advertising Screens /

IU22 IE33 EMB 453561419431 Excelsior Motherboard Ultrasound Accessories

IU22 IE33 EMB 453561419431 Excelsior Motherboard Ultrasound Accessories

Model Number:IU22/IE33
Minimum Order Quantity:1
Delivery Time:2-4 work days
Payment Terms:T/T, Western Union
Price:Negotiable
Packaging Details:Neutral Package
Contact Now

Add to Cart

Verified Supplier
Location: Guangzhou Guangdong China
Address: Room 1705,Office Building B1,Wanda Plaza,No.2707,Kaichuang Road,Guangzhou,Guangdong,China
Supplier`s last login times: within 16 hours
Shipping
lt's easy to get a shipping quote! Just click the button below and complete the short form.
Get Shipping Quote
Product Details Company Profile
Product Details

IU22/IE33 EMB 453561419431Excelsior Motherboard Ultrasound Parts Accessories healthcare solutions


IU22/IE33 EMB (excelsior motherboard) (P/N:453561419431)


1. Repair time: 2-4 days
2. Warranty: 60 days
3. Part number: 453561419431/453561382231/453561419431
4. Compatiable with iU22/iE33


Various GE//Siemens/Toshiba/Hitachi/ Biosound ultrasonic boards are within our repair/ mintenance range.



Other ultrasound parts related to that we can offer:


BrandSystemDescription
iU22/iE33Front End Controller 453561278261/453561278266/453561464291/453561153751
iU22/iE33excelsior motherboard 453561419431/453561382231/453561419431
iU22/iE33Unified Motherboard 453561254492 453561360251
iE33G Cart Channel Board 453561303332
iE33TI board 453561167791
iE33Front End Controller board 453561278265
iE33PC components
iE33/iU22version G Cart power boardMP6-3L-0M 73-560-7011 453561642151/453561395402/453561395432
ClearVue350AC/DCpower board
ClearVue350numeric keyboard
ClearVue350track board
CX50/CX30AC power board adapter 453561367414
CX50Channel board 453561662431
CX50/CX30power board 453561375144
CX50control panel 453561685791
CX50monitor
CX50systems 3.1.1
CX50TI board 453561473251
CX50QWERY Alphanumeric Keyboard numeric keyboard 453561364341
EPIQ 5ACQ Acquisition Module board 453561734844/ 453561704246
EPIQ 5channel board 453561704244 version A
Affiniti 50Gmother board 453561736531B
Affiniti 50ACB Assy acquisition control board
Affiniti 70ACB Assy acquisition control board
ATLHDI-3500/HDI-5000AIFOM ASSY 7500-1413-03A
ATLHDI-3500/HDI-5000Module Assy 3500-3079-01
ATLHDI-3500/HDI-5000power board 2500-1342-02A
ATLHDI-3500/HDI-5000SPM 3500-2988
ATLHDI-3500/HDI-5000PIM board 7500-1917-02c

Knowledge Point


Color Doppler flow imaging


Color Doppler flow imaging system can simultaneously display B-type image and Doppler blood flow data (blood flow direction, flow velocity, flow dispersion) of dual ultrasound scanning system. Color power angio(CPA) detected the backscattered energy of blood cells in the blood flow, which did not distinguish the flow direction, and had nothing to do with the angle θ (the angle between the direction of sound wave and the direction of blood flow). CPA can improve the sensitivity of blood flow detection, especially suitable for displaying low-speed blood flow of small vessels, but can not show the direction of blood flow.


Common failures of color Doppler ultrasound


1. Control panel failure

2. System software, application software failure

3. Back end failure

4. Power failure (Main power supply, Low-voltage power supply, High-voltage power supply)

5. Transducer Probe failure

6. Front-end failure (Interface board, Transmitter, Receiver, Control, VIDEO, Front-end connection)

7. Display failure (Display, Workstation, Touch screen)

8. Failure caused by external environment


Front end troubleshooting summary


1. The front and back connection processing board has multiple functions

2. TR Board, image processing

3. Probe interface board failure

4. The back end board is responsible for the whole machine

5. The video board is responsible for image problems

China IU22 IE33 EMB 453561419431 Excelsior Motherboard Ultrasound Accessories supplier

IU22 IE33 EMB 453561419431 Excelsior Motherboard Ultrasound Accessories

Inquiry Cart 0