Harbor District Electric Heat Trace For Ballast Water Mineral Insulated Cable

Brand Name:MICH
Certification:ISO9001
Model Number:HDEHTBWMIAC
Minimum Order Quantity:1 meter
Delivery Time:in one month
Place of Origin:China
Contact Now

Add to Cart

Verified Supplier
Address: 1200 N Fuxing Rd Wutong Dist Tongxiang 314500 Zhejiang P. R China
Supplier`s last login times: within 1 hours
Product Details Company Profile
Product Details

Harbor District Electric Heat Trace For Ballast Water Mineral Insulated Armour Cable

Harbor District Electric Heat Trace for Ballast Water Mineral Insulated Armour Cable is a technical heating system with the core heating element of mineral insulated heating cable to secure the ballast water from icing and to maintain a certain temperature about 30 . It has been widely used for the harbor district of many projects.


Ship ballast water refers to the amount of water that is injected into the bottom of a ship as the center of gravity to make the ship in a seaworthy state.


Cable Structure


Specification

Heating cable instruction code


MI CU-B 16K320/60/2520/220/E1

No. 1 2 3 4 5 6 7


No.Instruction
1Sheath materialCU
2structure of cable componentsshown in table 1
3cable codesshown in table 2, 3 and 4
4length of heating cableIn meter
5Heating cable powerIn Watt
6heating cable voltageIn Volt
7heating cable voltageSee table 5

Cable Code


1 6 K 320

No. 1 2 3 4


Serial NO.Instruction
1core number1 or 2
2Voltage grade3=300V, 6=600V
3conductor materialsC,K
4cold resistance ×1000320=0.32Ω/m×1000

Table 1 Structure of Cable Element


Note: Model C, F and G are suitable for being used at temperature under 65


Table 4 Heating Cable Specification (300V Double Cores)


Cable CodeDiameterNominal resistance at +20Maximum manufacturing lengthUnit weight
mmΩ/mmkg/km
23C3.412.00.0034200708.10
23C4.411.30.0044220629.07
23C5.810.40.0058240537.73
23C8.69.000.0086260392.56
23C11.48.400.0114280343.89
23C13.88.000.0138300314.57
23C17.27.600.0172320286.27
23C237.100.023340252.98
23C34.46.600.0344360221.19
23C49.26.200.0492380197.64
23K16010.40.16220508.37
23K2409.000.24240392.56
23K3208.400.32265343.89
23K3848.000.384280314.57
23K4807.700.48300291.91
23K6407.100.64320252.98
23K9606.500.96350216.11

Note: the resistance value of 2-core cable in the above table is the measured value after the ends are twisted (i.e., single-core resistance X2);

For the use of 660V voltage occasions, please contact our company professionals;

Mark of (300)☆ is a recommended production length by MICH


China Harbor District Electric Heat Trace For Ballast Water Mineral Insulated Cable supplier

Harbor District Electric Heat Trace For Ballast Water Mineral Insulated Cable

Inquiry Cart 0