Convenient Electrical Control MI Heating Element Of Heater

Brand Name:MICH
Certification:ISO9001
Model Number:CECMIHEG
Minimum Order Quantity:1 meter
Delivery Time:in one month
Payment Terms:L/C, T/T
Contact Now

Add to Cart

Verified Supplier
Address: 1200 N Fuxing Rd Wutong Dist Tongxiang 314500 Zhejiang P. R China
Supplier`s last login times: within 1 hours
Product Details Company Profile
Product Details

Convenient Electrical Control Mineral Insulated Heating Element for Gardening


Convenient Electrical Control Mineral Insulated Heating Element for Gardening is for applications as below:


1. Winter Heating for the greenhouse crops;
2. Snow icing prevention for greenhouse;
3. Heating to promote seed growth;
4. Keep warm for favoring the lawn maintenance.


Mineral insulation Heating Element is to be designed based on selection of mineral insulated heating cable which is prefabricated in the manufacturer's workshop into a heating element that can be directly connected to the power supply. It is usually composed of heating cables, cold and hot joints, cold end cables, terminals, tail ends and lead wires, etc. There are the following types can be selected from including type A, Type B, Type C, Type D, Type E, Type F and Type G structures. Among them, Type A, B and C are only suitable for single-core heating cable, while type D, E, F and G are only suitable for double-core heating cable. It can be widely used on heating or heat tracing of process conveying pipes and accessories, pumps, reactor, cracking furnace, carburetor, flash evaporator, storage tank, storage tank, other devices and vessels etc.



The CML IEC Ex and ATEX explosion-proof certificates have granted for the mineral insulated heating cable products


.


Storage and handling


1. The product shall be stored in a dry room, centralized and classified, and measures shall be taken to prevent the product from mechanical damage.
2. During the storage period, it shall be inspected every three months: the appearance of the package shall be complete; the marks complete, the sealing end shall be tight, and the metal sheath shall be free from rust.
3. The ambient temperature of product storage shall be no less than -15℃, and the relative humidity shall be no more than 85%.
4. Necessary measures should be taken to prevent rain, moisture, falling and other mechanical damage during handling to prevent the products and packaging from being damaged.


Table 1 Heating Cable Specification (600V Single Conductor)

Cable CodeDiameterHDPE DiameterStandard resistance value at +20Maximum Production LengthUnit weight
mmmmΩ/mmkg/km
16C1.78.2100.0017350366.54
16C2.27.69.40.0022380307.77
16C2.97.08.80.0029400264.45
16C45.97.70.004600190.88
16C75.37.10.007600154.08
16C114.96.70.011600132.25
16C134.66.40.013600 (300)☆125.7
16C174.66.40.017600 (300)☆117.16
16C214.66.40.021600 (300)☆111.9
16C253.75.50.025600 (480)☆68.83
16C333.75.50.033600 (480)☆63.76
16C403.45.20.04600 (560)☆58.87
16C633.250.06360051.47
16K806.88.60.08370 (140)☆254.18
16K1005.270.1450 (240)☆162.11
16K1404.96.70.14600 (270)☆122.55
16K1974.456.250.197600 (330)☆111.32
16K2204.56.30.22600 (330)☆102.89
16K3154.36.10.315600 (350)☆91.44
16K3454.26.00.345600 (370)☆85.9
16K4504.05.80.45600 (400)☆80.73
16K6304.05.80.63600 (400)☆77.26
16K8003.55.30.8600 (530)☆61.48
16K12502.84.61.2560040.83
16K20002.84.62.060038.96

Table 2 Heating Cable Specification (600V Double Cores)


Cable CodeDiameterNominal resistance at +20Maximum manufacturing lengthUnit weight
mmΩ/mmkg/km
26C3.412.90.0034150783.76
26C4.412.20.0044160701.56
26C5.811.30.0058170606.16
26C8.69.900.0086180451.43
26C11.49.300.0114200400.05
26C13.89.000.0138210375.20
26C17.28.600.0172220344.90
26C238.000.023250303.25
26C34.47.500.0344280269.20
26C49.27.100.0492300243.84
26K2409.900.24180451.43
26K3209.300.32200400.05
26K3849.000.384210375.20
26K4808.600.48220344.90
26K6408.000.64250303.25
26K9607.500.96280269.20

Table 3 Heating Cable Specification (300V Double Cores)


Cable CodeDiameterNominal resistance at +20Maximum manufacturing lengthUnit weight
mmΩ/mmkg/km
23C3.412.00.0034200708.10
23C4.411.30.0044220629.07
23C5.810.40.0058240537.73
23C8.69.000.0086260392.56
23C11.48.400.0114280343.89
23C13.88.000.0138300314.57
23C17.27.600.0172320286.27
23C237.100.023340252.98
23C34.46.600.0344360221.19
23C49.26.200.0492380197.64
23K16010.40.16220508.37
23K2409.000.24240392.56
23K3208.400.32265343.89
23K3848.000.384280314.57
23K4807.700.48300291.91
23K6407.100.64320252.98
23K9606.500.96350216.11

Note: the resistance value of 2-core cable in the above table is the measured value after the ends are twisted (i.e., single-core resistance X2);

For the use of 660V voltage occasions, please contact our company professionals;

Mark of (300)☆ is a recommended production length by MICH


Table 4 terminal specifications


Model: A, D, EModel: B
Maximum Voltage(V)Maximum Current (A)Terminal SpecificationMaximum Voltage(V)Maximum Current (A)Terminal SpecificationMaximum Voltage(V)
60015E220E115E1
60020E225E220E1
60030E340E230E2
60050E370E250E2
60070E3100E370E2

Note 1: E1 means 1/2 "NPT;E2 means 3/4 "NPT;E3 represents 1 "NPT (taper thread);Additional connection thread requirements are available.

Note 2: the length of cold end cable with standard configuration is 2 meters. If you increase or decrease of length required, please contact our professional personnel.