Heating 300V Mineral Insulated Metal Sheathed Cable Two Cores

Brand Name:MICH
Certification:ISO9001
Model Number:CSTC300RMIHC
Minimum Order Quantity:1 meter
Delivery Time:in one month
Payment Terms:L/C, T/T
Contact Now

Add to Cart

Verified Supplier
Address: 1200 N Fuxing Rd Wutong Dist Tongxiang 314500 Zhejiang P. R China
Supplier`s last login times: within 1 hours
Product Details Company Profile
Product Details

Copper Sheathed Two Cores 300 V rated Mineral Insulated Heating Cable is a special magnesium oxide insulated mineral insulated heating cable outsheathed with a copper tube with a rate of 300 V voltage power connection.


Table 4 Heating Cable Specification (300V Double Cores)


Cable CodeDiameterNominal resistance at +20Maximum manufacturing lengthUnit weight
mmΩ/mmkg/km
23C3.412.00.0034200708.10
23C4.411.30.0044220629.07
23C5.810.40.0058240537.73
23C8.69.000.0086260392.56
23C11.48.400.0114280343.89
23C13.88.000.0138300314.57
23C17.27.600.0172320286.27
23C237.100.023340252.98
23C34.46.600.0344360221.19
23C49.26.200.0492380197.64
23K16010.40.16220508.37
23K2409.000.24240392.56
23K3208.400.32265343.89
23K3848.000.384280314.57
23K4807.700.48300291.91
23K6407.100.64320252.98
23K9606.500.96350216.11

Note: the resistance value of 2-core cable in the above table is the measured value after the ends are twisted (i.e., single-core resistance X2);

For the use of 660V voltage occasions, please contact our company professionals;

Mark of (300)☆ is a recommended production length by MICH


Application

Copper sheathed heating cable (MICU)Maximum output power(W/m)
Freezing Prevention for metal gutters and downpipes49
Freezing Prevention for non-metal gutters and downpipes16
Vessel and piping process temperature maintaining59
Freezing Prevention for metal containers and pipes59
Metal roof snow-melting49
High-density polyethylene outer sheathed copper sheathed heating cable (MIHC)
Freezing Prevention for metal containers and pipes26
Freezing Prevention non-metallic containers and pipes13
Snow melting on asphalt slopes82
Non-metallic roof ice or snow melting26
Freezing Prevention for metal gutters and downpipes26
Freezing Prevention for non - metallic gutters and downpipes16
Concrete floor heating33
Rising or defrosting prevention for cold storage ground23
Freezing Prevention for metal containers and pipes

99


Note: when heating cables are used for heat tracing of vessels and pipes, the maximum output power must be controlled to ensure that the sheath temperature does not exceed its maximum allowable temperature or the spontaneous combustion temperature of the area (for hazardous areas).


Specification

Heating cable instruction code


MI CU-B 16K320/60/2520/220/E1

No. 1 2 3 4 5 6 7

No.Instruction
1Sheath materialCU
2structure of cable componentsshown in table 1
3cable codesshown in table 2, 3 and 4
4length of heating cableIn meter
5Heating cable powerIn Watt
6heating cable voltageIn Volt
7heating cable voltageSee table 5

Cable Code

1 6 K 320

No. 1 2 3 4

Serial NO.Instruction
1core number1 or 2
2Voltage grade3=300V, 6=600V
3conductor materialsC,K
4cold resistance ×1000320=0.32Ω/m×1000

Cable Structure

Table 1 Structure of Cable Element

Table 5 terminal specifications


Model: A, D, EModel: B
Maximum Voltage(V)Maximum Current (A)Terminal SpecificationMaximum Voltage(V)Maximum Current (A)Terminal SpecificationMaximum Voltage(V)
60015E220E115E1
60020E225E220E1
60030E340E230E2
60050E370E250E2
60070E3100E370E2

Note 1: E1 means 1/2 "NPT;E2 means 3/4 "NPT;E3 represents 1 "NPT (taper thread);Additional connection thread requirements are available.

Note 2: the length of cold end cable with standard configuration is 2 meters. If you increase or decrease of length required, please contact our professional personnel.


Corresponding reference table between the output power and sheath temperature



Note: when applying a copper conductor heating cable, please pay attention to the conversion of its heated hot resistance and unheated cold resistance.


Anticorrosive specification


Material

MICU

MIHC
SulfateNot recommendExcellent
Hydrochloric acidNot recommendExcellent
Hydrofluoric acidAcceptableAcceptable
PhosphateAcceptableAcceptable
CarbonateNot recommendAcceptable
Organic acidAcceptableNot recommend
Alkali metalAcceptableAcceptable
Sea waterNot recommendAcceptable
ChlorideData checking requiredAcceptable

Explosion-proof instructions


MIAL series heating cable with explosion-proof terminal, can be used in potential explosive environment. Authenticated by the Chinese CQST, in accordance with Chinese GB3836 explosion-proof electrical standards, they can be applicable to A, B, C (C1D2) level of explosion-proof electrical equipment.


MI CU-B 16K320/60/2520/220/E1

No. 1 2 3 4 5 6 7

China Heating 300V Mineral Insulated Metal Sheathed Cable Two Cores supplier

Heating 300V Mineral Insulated Metal Sheathed Cable Two Cores

Inquiry Cart 0