Home /Batteries /

7KVA 8KVA 6KVA Solar Inverter 48v Dc To 3 Phase Ac Inverter With 200A MPPT

7KVA 8KVA 6KVA Solar Inverter 48v Dc To 3 Phase Ac Inverter With 200A MPPT

Brand Name:Leeque
Certification:CE&IEC
Model Number:YQHDSXT4KVA-8KVA
Minimum Order Quantity:1
Delivery Time:5-25days
Payment Terms:T/T, Western Union, MoneyGram
Contact Now

Add to Cart

Active Member
Supplier`s last login times: within 30 hours
Shipping
lt's easy to get a shipping quote! Just click the button below and complete the short form.
Get Shipping Quote
Product Details Company Profile
Product Details

Product model:

YQHDSXT series 3 phrase hybrid power inverter4KVA/6KVA/7KVA/8KVADC48V/96V/192V invert to AC380V/400V ,with built-in10A-200A MPPT/PWM charge controller .

Product certification

CE,IEC,TLC

Application area

YQHDSXTseries 3 phase hybrid power inverter can be used in air conditioner,refrigerator,water pump,bench drill and other electrical appliances with motors whose total power not exceeding 4kVA,6kva,7kva or 8kva .

Product Description

Feature

  1. Pure sine wave output;
  2. Low DC voltage,saving system cost;
  3. Wide LCD screen,clearly and precisely shows icon data;
  4. AC charge current 0-45A adjustable;
  5. 100% imbalance loading design,3times peak power;
  6. Setting different working based on variable usage requirements;
  7. DC first/AC first optional;
  8. Various communication ports and remote controls(RS232/RS485/APP/SNMP/GSM optional)
  9. Three phase Built-im MPPT or PWM solar charge controller

3 phase hybrid Power charger bybrid Inverter parameters

Model:YQHDSXT4KVA6KVA7KVA8KVA
Rated Power3.2KW4.8KW5.6KW6.4KW
Peak Power(20ms)9.6KW14.4KW16.8KW19.2KW
Start Motor3HP4HP4HP4HP
Battery Voltage48/96/192VDC
Size(L*W*Hmm)565*300*775
Packing Size(L*W*Hmm)625*360*895
N.W.(kg)58737580
G.W.(kg)(Carton Packing)71868893
Installation methodTower
Parameter
InputDC Input Voltage Range10.5-15VDC(Single battery voltage)
AC Input Voltage Range380VAC/400VAC±10%(customized 190VAC/200VAC)
AC Input Frequency Range45Hz~65Hz
Max AC charging current20A/10A/5A20A/10A/5A20A/10A/5A25A/15A/10A
AC charging methodThree-stage(constant current,constant voltage,floating charge)
Phase3/N/PE

Output

Efficiency(Battery Mode)≥85%
Output Voltage(Battery Mode)380VAC/400VAC±10%(customized 190VAC/200VAC)
Output Frequency(Battery Mode)50/60Hz±1%
Output Wave(Battery Mode)Pure Sine Wave
Output Waveform distortionLinear load≤3%
Efficiency(AC Mode)>99%
Output Voltage(AC Mode)Conforming to AC input
Output Frequency(AC Mode)Conforming to AC input
Phase3/N/PE
No load loss(Battery Mode)≤1% rated power
No load loss(AC Mode)≤2% rated power( charger does not work in AC mode)
No load loss(Energy saving Mode)≤10W
Battery Type(optional)U0:Gel U.S.ACharge Voltage:14V;Float Voltage:13.7V(Single battery voltage)
U1:A.G.M.1Charge Voltage:14.1V;Float Voltage:13.4V(Single battery voltage)
U2:A.G.M.2Charge Voltage:14.6V;Float Voltage:13.7V(Single battery voltage)
U3:Sealed lead AcidCharge Voltage:14.4V;Float Voltage:13.6V(Single battery voltage)
U4:Gel EuropeanCharge Voltage:14.4V;Float Voltage:13.8V(Single battery voltage)
U5: Open Lead AcidCharge Voltage:14.8V;Float Voltage:13.5V(Single battery voltage)
U6:Calcuim(open)Charge Voltage:15.1V;Float Voltage:13.6V(Single battery voltage)
U7:Sulphation cycle15.5V for 4hrs
Customize batteryCharge and discharge parameters of different types of batteries can be customized according to user requirements.

Protection


Battery undervoltage alarm11V(Single battery voltage)
Battery undervoltage protection10.5V Single battery voltage)
Battery overvoltage alarm15V(Single battery voltage)
Battery overvoltage protection17V(Single battery voltage)
Battery overvoltage recovery voltage14.5V(Single battery voltage)
Overload power protectionAutomatic protection(battery mode),circuit breaker or insurance(AC mode)
Inverter Output short circuit protectionAutomatic protection(battery mode),circuit breaker or insurance(AC mode)
Temperature protection>90°C(Shut down output)
AlarmANormal working condition,buzzer has no alarm sound
BBuzzer sounds 4 times per second when battery failure,voltage abnormality,overload protection
CWhen the machine is turned on for the first time,the buzzer will prompt 5 when the machine is normal.
Inside Solar controllerCharging ModePWM or MPPT
Charging current48V System:10A,20A,30A,40A,50A,60A; 96V/192V System:50A,100A,150A,200A
PV Input Voltage Range48V System:60V-88V;96V System:120V-176V;192V System:240V-352V;
Max PV Input Voltage((At 25℃)48V System:100V;96V System:200V;192V System:400V;
PV Array Maximum Power

48V System:560W,1120W,1680W,2240W,2800W,3360W;

96V System:5.6KW,11.2KW,8.4KW*2,11.2KW*2
192V System:11.2KW,22.4KW,16.8KW*2,22.4KW*2;

Standby loss≤3W
Maximu conversation efficiency>95%
Working ModeBattery First/AC First/Saving Energy Mode
Transfer Time≤4ms
DisplayLCD
Thermal methodCooling fan in intelligent control
communicationRS232/RS485/APP/SNMP/GSM(Optional)
EnvironmentOperating temperature-10℃~40℃
Storage temperature-15℃~60℃
Noise≤65dB
Elevation2000m(More than derating)
Humidity0~95%( No condensation)
Note:All specifications are subject to charge without prior notice
China 7KVA 8KVA 6KVA Solar Inverter 48v Dc To 3 Phase Ac Inverter With 200A MPPT supplier

7KVA 8KVA 6KVA Solar Inverter 48v Dc To 3 Phase Ac Inverter With 200A MPPT

Inquiry Cart 0