Three Phase Smart Meter with Multiple communication interfaces

General introduction

Three Phase Smart Meter with Multiple communication interfaces is with wide voltage range and four tariffs, and used for measuring the import and export active and reactive energy. It also supports optical port and Plug& Play module such as GPRS, RF, PLC, ZigBee, etc. The meter includes metering, RTC, load control unit and other component.

Main functions

  • LCD display​

  • Active, reactive impulse output

  • Abnormal power consumption alarm

  • Remote disconnection and reconnection control

  • One RS485, one RS232 and one optical port, all interfaces are independent

  • Plug& Play modules (GPRS,3G, RF, PLC etc.)

  • TOU for import and export active energy, reactive energy and apparent energy

  • TOU for import and export active M.D., reactive M.D. and apparent M.D. with timestamp

  • TOU for import and export active cumulative demand, reactive cumulative demand and apparent cumulative demand

  • TOU for average power factor

  • TOU for average frequency

  • Billing (automatically or manual mode)

  • M.D. reset

  • Recording Multi-channel load profile

  • Measuring voltage, current, neutral current, active power, reactive power, apparent power, power factor, phase angle, frequency per phase, etc.

  • Events logs: power outage, demand reset, under voltage, overvoltage, phase loss, current reverse, voltage phase sequence reverse, voltage unbalance, current unbalance, meter cover open, meter terminal cover open, etc.

  • Hardware failure alarm

  • Meter reads when power outage

  • Power quality monitor: under voltage, overvoltage, phase loss, voltage unbalance, current unbalance, etc.

  • Anti-tamper: phase bypass, current reverse, voltage phase sequence reverse, meter cover open, meter terminal cover open, etc.

  • With KEMA Certificate.

Technical specifications

Itemscontents
StandardsIEC62052-11; IEC62053-21;IEC62053-22; IEC62053-23;IEC62056-21
ProtocolIEC62056-21;IEC62056-42;IEC62056-46;IEC62056-53;IEC62056-61;IEC62056-62;
AccuracyActive: Class 0.2S,0.5S or Class 1 Reactive: Class2
Reference voltage3×57.7/100V;3×120/208V;3×220/380V;3×230/400V
CurrentCurrent transformer connection:1.5(6)A,5(6)A,5(10)A, Direct connection:
10(40)A,10(60)A,20(80)A,10(100)A
Reference frequency50/60 Hz
Power consumption<1.5W, 6VA(per phase)
Operation voltage range0.8Un~1.2Un
Limited operation voltage range0.7Un~1.3Un
Operation temperature-25℃~ +60℃
Limited operation temperature range-40℃~ +70℃
RTC deviation≤0.5s/d
Size290mm(L)×170mm(W)×85mm(H)
Life time15 years
Net weightAbout 2.8kg

AMI System Architecture Diagram

Main Functions

1.Maintenance of system operation; Management of authority; Management of equipment's archives.
2.Collection of equipment's data. The collection plan can be configured. .
3.Electric Data analysis and power grid quality analysis.
4.Comprehensive line loss analysis.
5.Energy measurement equipment monitoring.
6.Remote control (electricity cut-off/switch-on)..
7.Electric data publishing..
8.Connection interface with other system..

AMI System advantages


1.Flexibility of configuration:
1.1 Function modularization: It can customize the equipment and separately deploy the modules according to the size of the management scale.
1.2 The function is hierarchically designed, which can guarantee clear logic, convenient maintenance and the stable operation.

2.Diversity of management:
Managing range covers the different types of energy consumed objects, such as Substations, Users with special transformer, Distribution transformers, Residential Users, etc. It can configure the relevant managing function according to the type of object.

3.Compatibility of equipments:
The users can choose the appropriate mode of network (such as GPRS, PLC, WSN or 485), the collection equipments (such as various energy meters or concentrators) and the operation protocol of equipments according to their own situation. The system can provide support or expansion.