40.5KV 1600A AC 50/60Hz KYN61-40.5 IEC ISO GB electrical switchgear

33KV switchgear panel, metal-clad MV switchgear power switchgear panel

KYN61-40.5KV medium voltage switchgear,
Knkong/ABB/Schneider VCB
40.5KV, 3-phase, AC 50/60Hz
Complete ISO IEC standard
For design switchgear SLD plan and layout plan (Single Line Drawing) service please inquiry by email.
Inquire

Product Introduction

Standards
GB3906-2006 "3~35kV AC Metal-enclosed Switchgear"
GB11022-89 "General Technical Requirements for High Voltage Switchgear"
IEC60298 "AC metal-enclosed switchgear and control equipment with rated voltage above 1kV and below 50kV"
DL404-97 "Technical Conditions for Ordering Indoor AC High Voltage Switchgear"
Use environment
Normal environmental conditions
1. The upper limit of ambient air temperature: +40℃, the lower limit: -10℃, and the daily average temperature does not exceed 35℃;
2. The altitude does not exceed 1000m;
3. The daily average relative humidity is not more than 95%, and the monthly average is not more than 90%;
4. The earthquake intensity does not exceed 8;
5. The daily average value of water vapor pressure does not exceed 2.2Kpa, and the monthly average value does not exceed 1.8kpa;
6. There is no fire, explosion hazard, severe pollution, chemical corrosion and severe vibration.
Special working conditions
When used under normal environmental conditions beyond the specified, the user and the manufacturer shall negotiate.

Technical data

ItemsUnitData
VoltageKV40.5
FrequencyHz50
CurrentA1250,1600,2000
Short-circuit Breaking CurrentKA25,31.5
Making Current (Peak)KA63,80
4s Thermal Stability CurrentKA25,31.5
Dynamic Current (Peak)KA63,80
Insulation Level1min Power Frequency Withstand Voltage (r.m.s)KV95
Lightning Impulse Withstand Voltage (Peak)KV185
1min Power Frequency Voltage Across the open gap (r.m.s)KV118
Lightning Impulse Withstand Voltage Across the open gap (Peak)KV215
Enclosure Protection Class

Enclosure IP4X,

Between Compartments IP2X

Enclosure Dimension (Width*Depth*Height)mm1400*2800*2600
1600*2800*2600
Type of Circuit BreakerVCB: ZN85-40.5
SF6 Circuit Breaker

*Note: order switchgear should provide SLD(Single-line diagram) by customer


Main components characteristics:


VS1-40.5 Indoor Vacuum Circuit Breaker

Rating voltage: 40.5kV

Rating current: 630 1250 1600 2000 2500A

Rating short circuit breaking current: 20 25 31.5KA

Mechanical life: no less than 20,000 times


VS1-40.5 Technical data

ItemsUnitDate
voltage

KV

40.5
short-time power frequency withstand voltage (1min)95
lightning impulse withstand voltage (peak)185
frequencyHz50/60
currentA1250 1600 2000 2500 4000
short-circuit drop-out currentKA25 31.5
short-time withstand current25 31.5
short-time continual times4
peak withstand currentKA63 80
short-circuit closing current63 80
single/ back-to-back capacitor bank drop-out currentA630/400
Opening time (rated volt.)ms35~60
Closing time (rated volt.)50~100
Mechanical lifetimes20000
break times for rated short drop-out currents20
operation voltageVAC110/220 DC110/220
current of power storing motorW230
Average opening speedm/s1.6~2.0
Average closing speed0.5~0.8
operation procedure

opening-0.3s-closing

opening-180s-closing opening


Knkong Electric 33KV switchgear has served the international market for over the past 10 years.